Detection zones
The detection zones of ultrasonic sensors
The most important criterion to bear in mind when selecting an ultrasonic sensor is its detection range and the associated three-dimensional detection zone.
In measuring the sensors various standard reflectors are introduced into the detection zones from the side and the points at which these reflectors are detected by the sensor are marked.
Objects may be introduced into the detection zone from any direction.
The red areas
are determined with a thin round bar (10 or 27 mm dia. depending on type of sensor) and indicate the typical operating range of a sensor.
In order to obtain the blue areas,
a plate (500 x 500 mm) is introduced into the beam spread from the side. In doing so, the optimum angle between plate and sensor is always employed. This therefore indicates the maximum detection zone of the sensor. It is not possible to evaluate ultrasonic reflections outside the blue beam spread.
A reflector with reflective properties inferior to those of the round bar can be detected in a zone that is smaller than that indicated by the red area. On the other hand, a reflector with better reflective properties will be detected in a zone with a size somewhere between that of the red and blue areas.
A sensor's blind zone determines its smallest permissible detection range. No objects or disturbing reflectors should be placed in the blind zone because this can lead to incorrect measurements.
The operating ranges
given in the diagrams specify the distance at which the ultrasonic sensor can measure common reflectors with sufficient operating reserve. The sensor can also be employed for distances up to its maximum range in the case of good reflectors.

The diagrams are valid for 20°C, 50% relative humidity and normal pressure.
The attenuation of sound in the air
depends on the temperature and pressure of the air as well as its relative humidity. The physical relationships are complex and have different effects at different ultrasonic frequencies. For simplicity we can say that the attenuation in the air increases with rising temperature and rising humidity. This necessitates a reduction in the size of the detection zones.
With a lower relative humidity and falling temperatures, the attenuation in the air decreases and the detection zones enlarge accordingly.
The reduction in the size of the detection zone is essentially compensated for by the sensor's operating reserves. And at temperatures below 0 °C some sensors can operate over distances certainly twice as large as those given here.
As the pressure of the air rises, so the attenuation in the air drops considerably. This aspect should be taken into account for applications involving overpressure. Sound propagation is impossible in a vacuum.
![]()
|
| |
|
20 mm blind zone |
|
|
| |
|
50 mm blind zone |
![]() |
|
| |
|
30 mm blind zone |
|
|
| |
|
65 mm blind zone |
|
|
| |
|
120 mm blind zone |
|
|
| |
|
200 mm blind zone |
|
|
| |
|
350 mm blind zone |
|
|
| |
|
600 mm blind zone |
|























