Version: V00016551.00000023Release Date: 2026-04-14


dbk+4/Empf/3CFF/M18
Vendor ID 419 (0x01a3) Vendor Logo
Vendor Name microsonic GmbH
Vendor Text Unser Herz schallt ultra
Vendor URL https://www.microsonic.de
Device ID 88 (0x000058)
DeviceFamily dbk+
Features
Block Parameter yes
Data Storage yes
Profile Characteristic 0x000a (Device Profile: Measuring Sensor), 0x4000 (Common Application Profile: Identification and Diagnosis), 0x800c (Function Class: Sensor control), 0x8101 (Function Class: Locator), 0x8102 (Function Class: Product URI), 0x8103 (Function Class: ?Unknown?)
Supported Access Locks Parameter: no, Data Storage: no, Local Parameterization: yes, Local User Interface: yes
Communication
IO-Link Revision V1.1
Transmission Rate230400 bit/s (COM3)
Minimum Cycle Time 2 ms
SIO Mode Supported yes
M-Sequence CapabilityPREOPERATE = TYPE_1_2 with 2 octets on-request data
OPERATE = TYPE_2_V with 2 octets on-request data
ISDU supported
Device Variant dbk+4/Empf/3CFF/M18
Description Ultraschall Doppelbogenkontrolle, 3 Steuereingänge, 2 Push-Pull Schaltausgänge.
Product ID 16551
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeNo connector (just the cable)
Connection Symbol Connection Symbol
- wire 1 brown; L+; +Ub
- wire 2 white; Other; Push-Pull (D1)
- wire 3 (light) blue; L-; -Ub
- wire 4 black; C/Q; Push-Pull (D2)
- wire 5 grey (slate); NC; Com (C3)
- wire 6 pink; NC; C2
- wire 7 violet (purple); NC; C1

ProcessData id=P_ProcessData

ProcessDataIn "Eingangsprozessdaten" id=PI_SSP_PDI32_MDC32

bit length: 32
data type: 32-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer -32760 = Ausserhalb des Erfassungsbereiches (-), 32760 = Ausserhalb des Erfassungsbereiches (+), 32764 = keine Messdaten, 0..4095 MDC - Messwert Zeigt den aktuellen Messwert des Sensorelements an.
2 8 8-bit Integer MDC - Skala Zeigt den Multiplikator für den Messwert des Sensors an - 10exp(Scala).
3 2 6-bit UInteger 0 = inaktiv, 1 = Übersteuerung, 2 = Einzelbogen, 5 = Fehlbogen, 6 = Doppelbogen, 7 = Teach-in aktiv, 8 = Teach-in erfolgreich, 9 = Teach-in fehlerhaft Auswertung Auswertezustand.
4 1 Boolean false = Low, true = High Ausgang D1 Zustand des Schaltsignalkanals D1.
5 0 Boolean false = Low, true = High Ausgang D2 Zustand des Schaltsignalkanals D2.
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex 3 4 5
element bit 5 4 3 2 1 0    

ProcessDataOut "Ausgangsprozessdaten" id=PO_SSP_PDO8_CSC

bit length: 8
data type: 8-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = ein, true = aus CSC Aktivieren/Deaktivieren des Sensors. Wenn deaktiviert, wird ein Ersatzwert als Prozessdaten ausgegeben.
4 3 5-bit UInteger 0 = Rezept 1 (Standard), 1 = Rezept 2 (Dick), 2 = Rezept 3 (Dünn), 3 = Rezept 4 (Teach-in) Rezept Auswahl der Empfindlichkeitsklasse für die Grammaturbereiche »Standard«, »Dick« und »Dünn«, oder Auswahl individueller »Teach-in«.
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex 4 / / / / / / / / / / / / 1
element bit 4 3 2 1 0      

Standard Variable "Direkte Parameter - Seite 1" index=0 id=V_DirectParameters_1

description: Beinhaltet die notwendigen Parameter für Kommunikationseigenschaften und die Kennungen zur Gerätevalidierung.
data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger ro Reserviert
2 112 8-bit UInteger ro Master Zykluszeit Kommunikation: Aktuelle vom Master vorgegebene Zyklusdauer für die Kommunikation. Dieser Wert bestimmt den Prozessdatenzyklus.
3 104 8-bit UInteger ro Minimale Zykluszeit Kommunikation: Minimale Zyklusdauer der Kommunikation, die das Gerät unterstützt. Dieser Wert bestimmt den kleinsten möglichen Prozessdatenzyklus.
4 96 8-bit UInteger ro Nachrichtenfähigkeit Kommunikation: Information zur Struktur und den unterstützten Eigenschaften der Kommunikationsnachrichten.
5 88 8-bit UInteger 17 ro IO-Link Revisions-ID Kommunikation: Kennung für die aktuelle Revision des Kommunikationsprotokolls.
6 80 8-bit UInteger ro Prozessdatenlänge Eingang Kommunikation: Information zu Breite und Eigenschaften der Prozesseingangsdaten (Prozessdaten vom Gerät zum Master).
7 72 8-bit UInteger ro Prozessdatenlänge Ausgang Kommunikation: Information zu Breite der Prozessausgangsdaten (Prozessdaten vom Master zum Gerät).
8 64 8-bit UInteger ro Hersteller-ID 1 Identifikation: Höchstes Oktett der Herstellerkennung. Zusammen mit dem Parameter Hersteller-ID 2 ergibt dies den 16-Bit-Wert der von der IO-Link-Gemeinschaft vergebenen eindeutigen Herstellerkennung.
9 56 8-bit UInteger ro Hersteller-ID 2 Identifikation: Niedrigstes Oktett der Herstellerkennung. Zusammen mit dem Parameter Hersteller-ID 1 ergibt dies den 16-Bit-Wert der von der IO-Link-Gemeinschaft vergebenen eindeutigen Herstellerkennung.
10 48 8-bit UInteger ro Geräte-ID 1 Identifikation: Höchstes Oktett der Gerätekennung. Zusammen mit den Parametern Geräte-ID 2 und 3 ergibt dies den 24-Bit-Wert der herstellerspezifischen Gerätekennung.
11 40 8-bit UInteger ro Geräte-ID 2 Identifikation: Mittleres Oktett der Gerätekennung. Zusammen mit den Parametern Geräte-ID 1 und 3 ergibt dies den 24-Bit-Wert der herstellerspezifischen Gerätekennung.
12 32 8-bit UInteger ro Geräte-ID 3 Identifikation: Niedrigstes Oktett der Gerätekennung. Zusammen mit den Parametern Geräte-ID 1 und 2 ergibt dies den 24-Bit-Wert der herstellerspezifischen Gerätekennung.
13 24 8-bit UInteger ro Reserviert
14 16 8-bit UInteger ro Reserviert
15 8 8-bit UInteger ro Reserviert
16 0 8-bit UInteger wo X Systembefehl Anwendung: Befehlsschnittstelle für Geräte ohne ISDU-Unterstützung. Gültigkeit und Ausführung von Befehlen werden nicht bestätigt.

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "Systembefehl" index=2 id=V_SystemCommand

description: Befehlsschnittstelle für Anwendungen. Eine positive Rückmeldung zeigt die vollständige und korrekte Ausführung der angeforderten Funktion an.
data type: 8-bit UInteger
allowed values: 126 = Locator Start, 127 = Locator Stop, 128 = Gerät rücksetzen, 129 = Anwendung rücksetzen, 130 = Werkseinstellung setzen, 131 = Back-to-box, 161 = Teach SP Start, 162 = Teach SP Stop, 169 = Teach Abbrechen, 170 = Messwertaufzeichnung manuell Triggern, 171 = Messwertaufzeichnung zurücksetzen, 172 = Zähler zurücksetzen, 173 = Teach-in Sender/Empfänger Abstand, 228 = Diagnosedaten zurücksetzen
access rights: wo
modifies other variables

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Gerätezugriffssperren" index=12 id=V_DeviceAccessLocks

description: Der Zugriff auf die Geräteparameter kann über entsprechende Flags im Parameter eingeschränkt werden.
data type: 16-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Entsperrt, true = Gesperrt Parameterschreibzugriff Diese Sperre verhindert den Schreibzugriff auf alle Schreib-/Leseparameter des Geräts mit Ausnahme des Parameters 'Gerätezugriffssperren'.
2 1 Boolean false = Entsperrt, true = Gesperrt Datenhaltung Diese Sperre verhindert den Schreibzugriff auf die Geräteparameter über die Datenhaltungsmechanismen.
3 2 Boolean false = Entsperrt, true = Gesperrt Lokale Parametrierung Diese Sperre verhindert, dass die Geräteeinstellungen über die lokalen Bedienelemente am Gerät geändert werden.
4 3 Boolean false = Entsperrt, true = Gesperrt Lokale Benutzerschnittstelle Die Sperre verhindert den Zugriff auf Geräteeinstellungen und -anzeigen über eine lokale Benutzerschnittstelle am Gerät. Die Benutzerschnittstelle ist deaktiviert.
Octet 0
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 1
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4 3 2 1

Standard Variable "Herstellername" index=16 id=V_VendorName

description: Herstellername, der einer Herstellerkennung zugeordnet ist.
data type: 64-octet String UTF-8
default value: "microsonic GmbH"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Herstellertext" index=17 id=V_VendorText

description: Zusätzliche Informationen zum Hersteller.
data type: 64-octet String UTF-8
default value: "Unser Herz schallt ultra"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Produktname" index=18 id=V_ProductName

description: Vollständiger Produktname.
data type: 64-octet String UTF-8
default value: "dbk+4/Empf/3CFF/M18"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Produkt-ID" index=19 id=V_ProductID

description: Herstellerspezifische Produkt- oder Typidentifikation (z. B. Artikelnummer oder Bestellnummer).
data type: 64-octet String UTF-8
default value: "16551"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Produkttext" index=20 id=V_ProductText

description: Zusätzliche Produktinformationen zum Gerät.
data type: 64-octet String UTF-8
default value: "Ultrasonic sensor"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Seriennummer" index=21 id=V_SerialNumber

description: Eindeutige, herstellerspezifische Kennung des einzelnen Geräts.
data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Hardwarerevision" index=22 id=V_HardwareRevision

description: Eindeutige, herstellerspezifische Kennung der Hardwarerevision des einzelnen Geräts.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Firmwarerevision" index=23 id=V_FirmwareRevision

description: Eindeutige, herstellerspezifische Kennung der Firmwarerevision des einzelnen Geräts.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Anwendungsspezifisches Kennzeichen" index=24 id=V_ApplicationSpecificTag

description: Möglichkeit ein Gerät mit benutzer- oder anwendungsspezifischen Informationen zu kennzeichnen.
data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Fehlerzähler" index=32 id=V_ErrorCount

description: Anzahl der aufgetretenen Fehler in der technologiespezifischen Anwendung seit dem letzten Einschalten oder Neustart.
data type: 16-bit UInteger
access rights: ro
dynamic

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Standard Variable "Gerätestatus" index=36 id=V_DeviceStatus

description: Anzeige des aktuellen Geräte- und Diagnosezustands.
data type: 8-bit UInteger
allowed values: 0 = Gerät ist OK, 1 = Wartung erforderlich, 2 = Außerhalb der Spezifikation, 3 = Funktionsprüfung, 4 = Ausfall
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Ausführlicher Gerätestatus" index=37 id=V_DetailedDeviceStatus

description: Liste aller aktuell anstehender Ereignisse des Geräts.
data type: Array[10] of 3-octet OctetString (subindex access not supported)
access rights: ro
dynamic

octet 0 1 2 3 4 5 6 7
bit offset 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176
subindex 1 1 1 2 2 2 3 3

octet 8 9 10 11 12 13 14 15
bit offset 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112
subindex 3 4 4 4 5 5 5 6

octet 16 17 18 19 20 21 22 23
bit offset 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48
subindex 6 6 7 7 7 8 8 8

octet 24 25 26 27 28 29  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 9 9 9 10 10 10  

Standard Variable "PD-Eingang" index=40 id=V_ProcessDataInput

description: Letzte gültige Prozesseingangsdaten des Geräts.
data type: see ProcessDataIn!
access rights: ro
dynamic

Standard Variable "PD-Ausgang" index=41 id=V_ProcessDataOutput

description: Letzte zum Gerät geschriebenen, gültigen Prozessausgangsdaten.
data type: see ProcessDataOut!
access rights: ro
dynamic

Variable "Funktionskennzeichen" index=25 id=V_CP_FunctionTag

description: Möglichkeit ein Gerät mit funktionsspezifischen Informationen zu kennzeichnen.
data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Ortskennzeichen" index=26 id=V_CP_LocationTag

description: Möglichkeit ein Gerät mit ortsspezifischen Informationen zu kennzeichnen.
data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Produkt-URI" index=27 id=V_CP_ProductURI

description: Stellt eine eindeutige Instanzidentifikation gemäß DIN-SPEC 91406 dar.
data type: 100-octet String US_ASCII
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 799 - 792 791 - 784 783 - 776 775 - 768 767 - 760 759 - 752 751 - 744 743 - 736

octet 8 9 10 11 12 13 14 15
bit offset 735 - 728 727 - 720 719 - 712 711 - 704 703 - 696 695 - 688 687 - 680 679 - 672

octet 16 17 18 19 20 21 22 23
bit offset 671 - 664 663 - 656 655 - 648 647 - 640 639 - 632 631 - 624 623 - 616 615 - 608

octet 24 25 26 27 28 29 30 31
bit offset 607 - 600 599 - 592 591 - 584 583 - 576 575 - 568 567 - 560 559 - 552 551 - 544

octet 32 33 34 35 36 37 38 39
bit offset 543 - 536 535 - 528 527 - 520 519 - 512 511 - 504 503 - 496 495 - 488 487 - 480

octet 40 41 42 43 44 45 46 47
bit offset 479 - 472 471 - 464 463 - 456 455 - 448 447 - 440 439 - 432 431 - 424 423 - 416

octet 48 49 50 51 52 53 54 55
bit offset 415 - 408 407 - 400 399 - 392 391 - 384 383 - 376 375 - 368 367 - 360 359 - 352

octet 56 57 58 59 60 61 62 63
bit offset 351 - 344 343 - 336 335 - 328 327 - 320 319 - 312 311 - 304 303 - 296 295 - 288

octet 64 65 66 67 68 69 70 71
bit offset 287 - 280 279 - 272 271 - 264 263 - 256 255 - 248 247 - 240 239 - 232 231 - 224

octet 72 73 74 75 76 77 78 79
bit offset 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176 175 - 168 167 - 160

octet 80 81 82 83 84 85 86 87
bit offset 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96

octet 88 89 90 91 92 93 94 95
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32

octet 96 97 98 99  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Messkonfiguration" index=200 id=V_Messkonfig

data type: 32-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 24 8-bit UInteger 20..60 40 Montageabstand Montageabstand in ganzzahligen mm zwischen Sender und Empfänger.
3 8 8-bit UInteger 0 = Standardleistung, 1 = Geringe Leistung 0 Sendeleistung Geringe Leistung des Senders nur für sehr dünne Materialien.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 / / / / / / 3 / / / / / /  
element bit 7 - 0   7 - 0    

Variable "Ein- und Ausschaltverzögerung" index=221 id=V_Delay

description: Einstellung in ms, wie lange der gleiche Zustand anliegen muss für einen Wechsel des Auswertezustands; Die Messzyklus-Zeit bestimmt die Schrittweite.
data type: 24-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 8-bit UInteger 0..100 20 Ausschaltverzögerung Doppelbogen Auschaltverzögerung für Doppelbogen in ms mit 2 ms Schrittweite.
2 8 8-bit UInteger 0..15 0 Einschaltverzögerung Fehlbogen Einschaltverzögerung für Fehlbogen in ms mit 2 ms Schrittweite.
3 0 8-bit UInteger 0..15 4 Einschaltverzögerung Doppelbogen Einschaltverzögerung für Doppelbogen in ms mit 2 ms Schrittweite.

octet 0 1 2  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 1 2 3  
element bit 7 - 0 7 - 0 7 - 0  

Variable "Ausgangskonfiguration" index=300 id=V_SchnittstellenAusgang

data type: 56-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 48 8-bit UInteger 1 = Doppelbogen , 4 = Einzelbogen, 5 = Fehlbogen, 6 = Übersteuerung 5 Ausgangsfunktion D1 Ausgangsfunktion für Schaltausgang D1.
2 40 8-bit UInteger 1 = Doppelbogen , 4 = Einzelbogen, 5 = Fehlbogen, 6 = Übersteuerung 1 Ausgangsfunktion D2 Ausgangsfunktion für Schaltausgang D2.
3 32 2-bit UInteger 3 Reserviert Reserviert.
4 24 2-bit UInteger 0 = High active, 1 = Low active 1 Ausgangslogik D1 Funktion Öffner/Schließer für D1.
5 16 2-bit UInteger 0 = High active, 1 = Low active 1 Ausgangslogik D2 Funktion Öffner/Schließer für D2.
Octet 0
bit offset 55 54 53 52 51 50 49 48
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 1
bit offset 47 46 45 44 43 42 41 40
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 39 38 37 36 35 34 33 32
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 3
element bit             1 0
Octet 3
bit offset 31 30 29 28 27 26 25 24
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 4
element bit             1 0
Octet 4
bit offset 23 22 21 20 19 18 17 16
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 5
element bit             1 0
Octet 5
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 6
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /

Variable "Eingangskonfiguration" index=301 id=V_SchnittstellenEingang

data type: 24-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 8-bit UInteger 0 Reserviert Reserviert.
2 8 8-bit UInteger 0 Reserviert Reserviert.
3 0 8-bit UInteger 1 = PNP erkennend, 2 = NPN erkennend 1 Eingangscharakteristik Eingangsbeschaltung der Steuereingänge C1-C3: +Ub aktiv (pnp-ansteuerbar) oder -UB aktiv (npn-ansteuerbar).

octet 0 1 2  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 1 2 3  
element bit 7 - 0 7 - 0 7 - 0  

Variable "Trigger und Synchronisation" index=350 id=V_SyncMux

data type: 32-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 24 8-bit UInteger 0 = Freilauf, 1 = Synchronisation, 2 = ext. Trigger-Pin, 3 = IO-Link Kommunikation 0 Trigger Kanal Der Trigger Kanal steuert den Messzyklus.
2 16 8-bit UInteger 0 = flankengetriggert, steigende Flanke, 1 = flankengetriggert, fallende Flanke, 3 = Pegel getriggert, High-aktiv, 4 = Pegel getriggert, Low-aktiv 0 Trigger Modus Auswahl des Trigger-Modus, z.B. für Messung im Schuppenstrom an der Bogendruckmaschine.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 2 / / / / / / / / / / / /  
element bit 7 - 0 7 - 0      

Variable "Teach-In" index=370 id=V_BedienungEingabe

data type: 8-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = inaktiv, 1 = aktiv 1 Modus

octet 0  
bit offset 7 - 0  
subindex 1  
element bit 7 - 0  

Variable "LED" index=371 id=V_BedienungAusgabe

data type: 8-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 0 = inaktiv, 1 = aktiv, 4 = FindMe! 1 Modus

octet 0  
bit offset 7 - 0  
subindex 1  
element bit 7 - 0  

Variable "Teach-in Konfiguration" index=400 id=V_TeachinKonfig

description: Der Teach-in-Prozess ermittelt die Eigenschaften des Materials in einen Zahlenwert.
data type: 32-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 24 8-bit UInteger 0 = aus, 4 = Materialbeschaffenheit 4 Typ Auswahl des auszuführenden Teach-In Typs über die Systemkommandos Start, Stop und Abbruch.
2 16 8-bit UInteger 5..80 20 Offset Vorgegebener Offsets zur Brechnung der Schaltschwelle für Doppelbogen.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 2 / / / / / / / / / / / /  
element bit 7 - 0 7 - 0      

Variable "Teach-in Ergebnis" index=401 id=V_SSP_TI_TeachResult

data type: 8-bit Record (subindex access not supported)
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 4-bit UInteger 0 = Untätig, 1 = Materialbeschaffenheit erfolgreich, 2 = Montageabstand erfolgreich, 4 = Warte auf Kommando, 5 = In Arbeit, 7 = Materialbeschaffenheit Fehler, 8 = Montageabstand Fehler 0 Teach-in Status
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 1
element bit         3 2 1 0

Variable "Rezeptspeicher-Konfiguration" index=500 id=V_Rezeptspeicher_Konfig

description: Im Rezeptspeicher können für Standard- und geringe Leistung jeweils vier unterschiedliche Materialien abgelegt werden. Der aktive Speicher wird über den Konfigurationsparameter ausgewählt.
data type: 8-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 1 = Rezept 1 (Standard), 2 = Rezept 2 (Dick), 3 = Rezept 3 (Dünn), 4 = Rezept 4 (Teach-in), 21 = Rezeptauswahl über Steuereingänge, 22 = Rezeptauswahl IO-Link PDO 21 Teach-in Rezeptspeicher Direktauswahl eines Rezepts oder Auswahl der Quelle für die Bestimmung des aktiven Rezepts.

octet 0  
bit offset 7 - 0  
subindex 1  
element bit 7 - 0  

Variable "Rezept" index=510 id=V_RezeptspeicherHV_Rezept1

description: Rezept für Messungen mit Standardleistung.
data type: 192-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 184 8-bit UInteger CRC Checksumme des Rezepts. Bei manuellen Veränderungen wird ein Event als Warnung ausgegeben.
2 80 13-octet OctetString Reserviert Reserviert.
3 64 12-bit UInteger 0..4095 Reserviert Reserviert.
4 48 12-bit UInteger 0..4095 Reserviert Reserviert.
5 32 12-bit UInteger 0..4095 Schwellwert Doppelbogen Untere Schaltschwelle für Ausgabe Doppelbogen erkannt.
6 31 Boolean false = inaktiv, true = aktiv Ein- und Ausschaltverzögerung Flag zum Aktivieren oder Deaktivieren aller Ein- und Ausschaltverzögerungen.
7 30 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
8 29 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
9 28 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
10 24 4-bit UInteger 2 = Doppelbogen Auswertungstyp Auswertungstyp.
11 8 12-bit UInteger 0..4095 Verstärkung Verstärkungsfaktor des Analogverstärkers.
12 0 4-bit UInteger 1..15 Sendelänge Länge des Sendeimpulses in Einzelschwingungen.
Octet 0
bit offset 191 190 189 188 187 186 185 184
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 1
bit offset 183 182 181 180 179 178 177 176
subindex 2
Octet 2
bit offset 175 174 173 172 171 170 169 168
subindex 2
Octet 3
bit offset 167 166 165 164 163 162 161 160
subindex 2
Octet 4
bit offset 159 158 157 156 155 154 153 152
subindex 2
Octet 5
bit offset 151 150 149 148 147 146 145 144
subindex 2
Octet 6
bit offset 143 142 141 140 139 138 137 136
subindex 2
Octet 7
bit offset 135 134 133 132 131 130 129 128
subindex 2
Octet 8
bit offset 127 126 125 124 123 122 121 120
subindex 2
Octet 9
bit offset 119 118 117 116 115 114 113 112
subindex 2
Octet 10
bit offset 111 110 109 108 107 106 105 104
subindex 2
Octet 11
bit offset 103 102 101 100 99 98 97 96
subindex 2
Octet 12
bit offset 95 94 93 92 91 90 89 88
subindex 2
Octet 13
bit offset 87 86 85 84 83 82 81 80
subindex 2
Octet 14
bit offset 79 78 77 76 75 74 73 72
subindex / / / / / / / / / / / / / / / / / / / / / / / / 3
element bit         11 10 9 8
Octet 15
bit offset 71 70 69 68 67 66 65 64
subindex 3
element bit 7 6 5 4 3 2 1 0
Octet 16
bit offset 63 62 61 60 59 58 57 56
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4
element bit         11 10 9 8
Octet 17
bit offset 55 54 53 52 51 50 49 48
subindex 4
element bit 7 6 5 4 3 2 1 0
Octet 18
bit offset 47 46 45 44 43 42 41 40
subindex / / / / / / / / / / / / / / / / / / / / / / / / 5
element bit         11 10 9 8
Octet 19
bit offset 39 38 37 36 35 34 33 32
subindex 5
element bit 7 6 5 4 3 2 1 0
Octet 20
bit offset 31 30 29 28 27 26 25 24
subindex 6 7 8 9 10
element bit         3 2 1 0
Octet 21
bit offset 23 22 21 20 19 18 17 16
subindex / / / / / / / / / / / / / / / / / / / / / / / / 11
element bit         11 10 9 8
Octet 22
bit offset 15 14 13 12 11 10 9 8
subindex 11
element bit 7 6 5 4 3 2 1 0
Octet 23
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 12
element bit         3 2 1 0

Variable "Rezept" index=511 id=V_RezeptspeicherHV_Rezept2

description: Rezept für Messungen mit Standardleistung.
data type: 192-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 184 8-bit UInteger CRC Checksumme des Rezepts. Bei manuellen Veränderungen wird ein Event als Warnung ausgegeben.
2 80 13-octet OctetString Reserviert Reserviert.
3 64 12-bit UInteger 0..4095 Reserviert Reserviert.
4 48 12-bit UInteger 0..4095 Reserviert Reserviert.
5 32 12-bit UInteger 0..4095 Schwellwert Doppelbogen Untere Schaltschwelle für Ausgabe Doppelbogen erkannt.
6 31 Boolean false = inaktiv, true = aktiv Ein- und Ausschaltverzögerung Flag zum Aktivieren oder Deaktivieren aller Ein- und Ausschaltverzögerungen.
7 30 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
8 29 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
9 28 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
10 24 4-bit UInteger 2 = Doppelbogen Auswertungstyp Auswertungstyp.
11 8 12-bit UInteger 0..4095 Verstärkung Verstärkungsfaktor des Analogverstärkers.
12 0 4-bit UInteger 1..15 Sendelänge Länge des Sendeimpulses in Einzelschwingungen.
Octet 0
bit offset 191 190 189 188 187 186 185 184
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 1
bit offset 183 182 181 180 179 178 177 176
subindex 2
Octet 2
bit offset 175 174 173 172 171 170 169 168
subindex 2
Octet 3
bit offset 167 166 165 164 163 162 161 160
subindex 2
Octet 4
bit offset 159 158 157 156 155 154 153 152
subindex 2
Octet 5
bit offset 151 150 149 148 147 146 145 144
subindex 2
Octet 6
bit offset 143 142 141 140 139 138 137 136
subindex 2
Octet 7
bit offset 135 134 133 132 131 130 129 128
subindex 2
Octet 8
bit offset 127 126 125 124 123 122 121 120
subindex 2
Octet 9
bit offset 119 118 117 116 115 114 113 112
subindex 2
Octet 10
bit offset 111 110 109 108 107 106 105 104
subindex 2
Octet 11
bit offset 103 102 101 100 99 98 97 96
subindex 2
Octet 12
bit offset 95 94 93 92 91 90 89 88
subindex 2
Octet 13
bit offset 87 86 85 84 83 82 81 80
subindex 2
Octet 14
bit offset 79 78 77 76 75 74 73 72
subindex / / / / / / / / / / / / / / / / / / / / / / / / 3
element bit         11 10 9 8
Octet 15
bit offset 71 70 69 68 67 66 65 64
subindex 3
element bit 7 6 5 4 3 2 1 0
Octet 16
bit offset 63 62 61 60 59 58 57 56
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4
element bit         11 10 9 8
Octet 17
bit offset 55 54 53 52 51 50 49 48
subindex 4
element bit 7 6 5 4 3 2 1 0
Octet 18
bit offset 47 46 45 44 43 42 41 40
subindex / / / / / / / / / / / / / / / / / / / / / / / / 5
element bit         11 10 9 8
Octet 19
bit offset 39 38 37 36 35 34 33 32
subindex 5
element bit 7 6 5 4 3 2 1 0
Octet 20
bit offset 31 30 29 28 27 26 25 24
subindex 6 7 8 9 10
element bit         3 2 1 0
Octet 21
bit offset 23 22 21 20 19 18 17 16
subindex / / / / / / / / / / / / / / / / / / / / / / / / 11
element bit         11 10 9 8
Octet 22
bit offset 15 14 13 12 11 10 9 8
subindex 11
element bit 7 6 5 4 3 2 1 0
Octet 23
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 12
element bit         3 2 1 0

Variable "Rezept" index=512 id=V_RezeptspeicherHV_Rezept3

description: Rezept für Messungen mit Standardleistung.
data type: 192-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 184 8-bit UInteger CRC Checksumme des Rezepts. Bei manuellen Veränderungen wird ein Event als Warnung ausgegeben.
2 80 13-octet OctetString Reserviert Reserviert.
3 64 12-bit UInteger 0..4095 Reserviert Reserviert.
4 48 12-bit UInteger 0..4095 Reserviert Reserviert.
5 32 12-bit UInteger 0..4095 Schwellwert Doppelbogen Untere Schaltschwelle für Ausgabe Doppelbogen erkannt.
6 31 Boolean false = inaktiv, true = aktiv Ein- und Ausschaltverzögerung Flag zum Aktivieren oder Deaktivieren aller Ein- und Ausschaltverzögerungen.
7 30 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
8 29 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
9 28 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
10 24 4-bit UInteger 2 = Doppelbogen Auswertungstyp Auswertungstyp.
11 8 12-bit UInteger 0..4095 Verstärkung Verstärkungsfaktor des Analogverstärkers.
12 0 4-bit UInteger 1..15 Sendelänge Länge des Sendeimpulses in Einzelschwingungen.
Octet 0
bit offset 191 190 189 188 187 186 185 184
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 1
bit offset 183 182 181 180 179 178 177 176
subindex 2
Octet 2
bit offset 175 174 173 172 171 170 169 168
subindex 2
Octet 3
bit offset 167 166 165 164 163 162 161 160
subindex 2
Octet 4
bit offset 159 158 157 156 155 154 153 152
subindex 2
Octet 5
bit offset 151 150 149 148 147 146 145 144
subindex 2
Octet 6
bit offset 143 142 141 140 139 138 137 136
subindex 2
Octet 7
bit offset 135 134 133 132 131 130 129 128
subindex 2
Octet 8
bit offset 127 126 125 124 123 122 121 120
subindex 2
Octet 9
bit offset 119 118 117 116 115 114 113 112
subindex 2
Octet 10
bit offset 111 110 109 108 107 106 105 104
subindex 2
Octet 11
bit offset 103 102 101 100 99 98 97 96
subindex 2
Octet 12
bit offset 95 94 93 92 91 90 89 88
subindex 2
Octet 13
bit offset 87 86 85 84 83 82 81 80
subindex 2
Octet 14
bit offset 79 78 77 76 75 74 73 72
subindex / / / / / / / / / / / / / / / / / / / / / / / / 3
element bit         11 10 9 8
Octet 15
bit offset 71 70 69 68 67 66 65 64
subindex 3
element bit 7 6 5 4 3 2 1 0
Octet 16
bit offset 63 62 61 60 59 58 57 56
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4
element bit         11 10 9 8
Octet 17
bit offset 55 54 53 52 51 50 49 48
subindex 4
element bit 7 6 5 4 3 2 1 0
Octet 18
bit offset 47 46 45 44 43 42 41 40
subindex / / / / / / / / / / / / / / / / / / / / / / / / 5
element bit         11 10 9 8
Octet 19
bit offset 39 38 37 36 35 34 33 32
subindex 5
element bit 7 6 5 4 3 2 1 0
Octet 20
bit offset 31 30 29 28 27 26 25 24
subindex 6 7 8 9 10
element bit         3 2 1 0
Octet 21
bit offset 23 22 21 20 19 18 17 16
subindex / / / / / / / / / / / / / / / / / / / / / / / / 11
element bit         11 10 9 8
Octet 22
bit offset 15 14 13 12 11 10 9 8
subindex 11
element bit 7 6 5 4 3 2 1 0
Octet 23
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 12
element bit         3 2 1 0

Variable "Rezept" index=513 id=V_RezeptspeicherHV_Rezept4

description: Rezept für Messungen mit Standardleistung.
data type: 192-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 184 8-bit UInteger CRC Checksumme des Rezepts. Bei manuellen Veränderungen wird ein Event als Warnung ausgegeben.
2 80 13-octet OctetString Reserviert Reserviert.
3 64 12-bit UInteger 0..4095 Reserviert Reserviert.
4 48 12-bit UInteger 0..4095 Reserviert Reserviert.
5 32 12-bit UInteger 0..4095 Schwellwert Doppelbogen Untere Schaltschwelle für Ausgabe Doppelbogen erkannt.
6 31 Boolean false = inaktiv, true = aktiv Ein- und Ausschaltverzögerung Flag zum Aktivieren oder Deaktivieren aller Ein- und Ausschaltverzögerungen.
7 30 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
8 29 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
9 28 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
10 24 4-bit UInteger 2 = Doppelbogen Auswertungstyp Auswertungstyp.
11 8 12-bit UInteger 0..4095 Verstärkung Verstärkungsfaktor des Analogverstärkers.
12 0 4-bit UInteger 1..15 Sendelänge Länge des Sendeimpulses in Einzelschwingungen.
Octet 0
bit offset 191 190 189 188 187 186 185 184
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 1
bit offset 183 182 181 180 179 178 177 176
subindex 2
Octet 2
bit offset 175 174 173 172 171 170 169 168
subindex 2
Octet 3
bit offset 167 166 165 164 163 162 161 160
subindex 2
Octet 4
bit offset 159 158 157 156 155 154 153 152
subindex 2
Octet 5
bit offset 151 150 149 148 147 146 145 144
subindex 2
Octet 6
bit offset 143 142 141 140 139 138 137 136
subindex 2
Octet 7
bit offset 135 134 133 132 131 130 129 128
subindex 2
Octet 8
bit offset 127 126 125 124 123 122 121 120
subindex 2
Octet 9
bit offset 119 118 117 116 115 114 113 112
subindex 2
Octet 10
bit offset 111 110 109 108 107 106 105 104
subindex 2
Octet 11
bit offset 103 102 101 100 99 98 97 96
subindex 2
Octet 12
bit offset 95 94 93 92 91 90 89 88
subindex 2
Octet 13
bit offset 87 86 85 84 83 82 81 80
subindex 2
Octet 14
bit offset 79 78 77 76 75 74 73 72
subindex / / / / / / / / / / / / / / / / / / / / / / / / 3
element bit         11 10 9 8
Octet 15
bit offset 71 70 69 68 67 66 65 64
subindex 3
element bit 7 6 5 4 3 2 1 0
Octet 16
bit offset 63 62 61 60 59 58 57 56
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4
element bit         11 10 9 8
Octet 17
bit offset 55 54 53 52 51 50 49 48
subindex 4
element bit 7 6 5 4 3 2 1 0
Octet 18
bit offset 47 46 45 44 43 42 41 40
subindex / / / / / / / / / / / / / / / / / / / / / / / / 5
element bit         11 10 9 8
Octet 19
bit offset 39 38 37 36 35 34 33 32
subindex 5
element bit 7 6 5 4 3 2 1 0
Octet 20
bit offset 31 30 29 28 27 26 25 24
subindex 6 7 8 9 10
element bit         3 2 1 0
Octet 21
bit offset 23 22 21 20 19 18 17 16
subindex / / / / / / / / / / / / / / / / / / / / / / / / 11
element bit         11 10 9 8
Octet 22
bit offset 15 14 13 12 11 10 9 8
subindex 11
element bit 7 6 5 4 3 2 1 0
Octet 23
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 12
element bit         3 2 1 0

Variable "Rezept" index=530 id=V_RezeptspeicherLV_Rezept1

description: Rezept für Messungen mit geringer Leistung.
data type: 192-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 184 8-bit UInteger CRC Checksumme des Rezepts. Bei manuellen Veränderungen wird ein Event als Warnung ausgegeben.
2 80 13-octet OctetString Reserviert Reserviert.
3 64 12-bit UInteger 0..4095 Reserviert Reserviert.
4 48 12-bit UInteger 0..4095 Reserviert Reserviert.
5 32 12-bit UInteger 0..4095 Schwellwert Doppelbogen Untere Schaltschwelle für Ausgabe Doppelbogen erkannt.
6 31 Boolean false = inaktiv, true = aktiv Ein- und Ausschaltverzögerung Flag zum Aktivieren oder Deaktivieren aller Ein- und Ausschaltverzögerungen.
7 30 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
8 29 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
9 28 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
10 24 4-bit UInteger 2 = Doppelbogen Auswertungstyp Auswertungstyp.
11 8 12-bit UInteger 0..4095 Verstärkung Verstärkungsfaktor des Analogverstärkers.
12 0 4-bit UInteger 1..15 Sendelänge Länge des Sendeimpulses in Einzelschwingungen.
Octet 0
bit offset 191 190 189 188 187 186 185 184
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 1
bit offset 183 182 181 180 179 178 177 176
subindex 2
Octet 2
bit offset 175 174 173 172 171 170 169 168
subindex 2
Octet 3
bit offset 167 166 165 164 163 162 161 160
subindex 2
Octet 4
bit offset 159 158 157 156 155 154 153 152
subindex 2
Octet 5
bit offset 151 150 149 148 147 146 145 144
subindex 2
Octet 6
bit offset 143 142 141 140 139 138 137 136
subindex 2
Octet 7
bit offset 135 134 133 132 131 130 129 128
subindex 2
Octet 8
bit offset 127 126 125 124 123 122 121 120
subindex 2
Octet 9
bit offset 119 118 117 116 115 114 113 112
subindex 2
Octet 10
bit offset 111 110 109 108 107 106 105 104
subindex 2
Octet 11
bit offset 103 102 101 100 99 98 97 96
subindex 2
Octet 12
bit offset 95 94 93 92 91 90 89 88
subindex 2
Octet 13
bit offset 87 86 85 84 83 82 81 80
subindex 2
Octet 14
bit offset 79 78 77 76 75 74 73 72
subindex / / / / / / / / / / / / / / / / / / / / / / / / 3
element bit         11 10 9 8
Octet 15
bit offset 71 70 69 68 67 66 65 64
subindex 3
element bit 7 6 5 4 3 2 1 0
Octet 16
bit offset 63 62 61 60 59 58 57 56
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4
element bit         11 10 9 8
Octet 17
bit offset 55 54 53 52 51 50 49 48
subindex 4
element bit 7 6 5 4 3 2 1 0
Octet 18
bit offset 47 46 45 44 43 42 41 40
subindex / / / / / / / / / / / / / / / / / / / / / / / / 5
element bit         11 10 9 8
Octet 19
bit offset 39 38 37 36 35 34 33 32
subindex 5
element bit 7 6 5 4 3 2 1 0
Octet 20
bit offset 31 30 29 28 27 26 25 24
subindex 6 7 8 9 10
element bit         3 2 1 0
Octet 21
bit offset 23 22 21 20 19 18 17 16
subindex / / / / / / / / / / / / / / / / / / / / / / / / 11
element bit         11 10 9 8
Octet 22
bit offset 15 14 13 12 11 10 9 8
subindex 11
element bit 7 6 5 4 3 2 1 0
Octet 23
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 12
element bit         3 2 1 0

Variable "Rezept" index=531 id=V_RezeptspeicherLV_Rezept2

description: Rezept für Messungen mit geringer Leistung.
data type: 192-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 184 8-bit UInteger CRC Checksumme des Rezepts. Bei manuellen Veränderungen wird ein Event als Warnung ausgegeben.
2 80 13-octet OctetString Reserviert Reserviert.
3 64 12-bit UInteger 0..4095 Reserviert Reserviert.
4 48 12-bit UInteger 0..4095 Reserviert Reserviert.
5 32 12-bit UInteger 0..4095 Schwellwert Doppelbogen Untere Schaltschwelle für Ausgabe Doppelbogen erkannt.
6 31 Boolean false = inaktiv, true = aktiv Ein- und Ausschaltverzögerung Flag zum Aktivieren oder Deaktivieren aller Ein- und Ausschaltverzögerungen.
7 30 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
8 29 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
9 28 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
10 24 4-bit UInteger 2 = Doppelbogen Auswertungstyp Auswertungstyp.
11 8 12-bit UInteger 0..4095 Verstärkung Verstärkungsfaktor des Analogverstärkers.
12 0 4-bit UInteger 1..15 Sendelänge Länge des Sendeimpulses in Einzelschwingungen.
Octet 0
bit offset 191 190 189 188 187 186 185 184
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 1
bit offset 183 182 181 180 179 178 177 176
subindex 2
Octet 2
bit offset 175 174 173 172 171 170 169 168
subindex 2
Octet 3
bit offset 167 166 165 164 163 162 161 160
subindex 2
Octet 4
bit offset 159 158 157 156 155 154 153 152
subindex 2
Octet 5
bit offset 151 150 149 148 147 146 145 144
subindex 2
Octet 6
bit offset 143 142 141 140 139 138 137 136
subindex 2
Octet 7
bit offset 135 134 133 132 131 130 129 128
subindex 2
Octet 8
bit offset 127 126 125 124 123 122 121 120
subindex 2
Octet 9
bit offset 119 118 117 116 115 114 113 112
subindex 2
Octet 10
bit offset 111 110 109 108 107 106 105 104
subindex 2
Octet 11
bit offset 103 102 101 100 99 98 97 96
subindex 2
Octet 12
bit offset 95 94 93 92 91 90 89 88
subindex 2
Octet 13
bit offset 87 86 85 84 83 82 81 80
subindex 2
Octet 14
bit offset 79 78 77 76 75 74 73 72
subindex / / / / / / / / / / / / / / / / / / / / / / / / 3
element bit         11 10 9 8
Octet 15
bit offset 71 70 69 68 67 66 65 64
subindex 3
element bit 7 6 5 4 3 2 1 0
Octet 16
bit offset 63 62 61 60 59 58 57 56
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4
element bit         11 10 9 8
Octet 17
bit offset 55 54 53 52 51 50 49 48
subindex 4
element bit 7 6 5 4 3 2 1 0
Octet 18
bit offset 47 46 45 44 43 42 41 40
subindex / / / / / / / / / / / / / / / / / / / / / / / / 5
element bit         11 10 9 8
Octet 19
bit offset 39 38 37 36 35 34 33 32
subindex 5
element bit 7 6 5 4 3 2 1 0
Octet 20
bit offset 31 30 29 28 27 26 25 24
subindex 6 7 8 9 10
element bit         3 2 1 0
Octet 21
bit offset 23 22 21 20 19 18 17 16
subindex / / / / / / / / / / / / / / / / / / / / / / / / 11
element bit         11 10 9 8
Octet 22
bit offset 15 14 13 12 11 10 9 8
subindex 11
element bit 7 6 5 4 3 2 1 0
Octet 23
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 12
element bit         3 2 1 0

Variable "Rezept" index=532 id=V_RezeptspeicherLV_Rezept3

description: Rezept für Messungen mit geringer Leistung.
data type: 192-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 184 8-bit UInteger CRC Checksumme des Rezepts. Bei manuellen Veränderungen wird ein Event als Warnung ausgegeben.
2 80 13-octet OctetString Reserviert Reserviert.
3 64 12-bit UInteger 0..4095 Reserviert Reserviert.
4 48 12-bit UInteger 0..4095 Reserviert Reserviert.
5 32 12-bit UInteger 0..4095 Schwellwert Doppelbogen Untere Schaltschwelle für Ausgabe Doppelbogen erkannt.
6 31 Boolean false = inaktiv, true = aktiv Ein- und Ausschaltverzögerung Flag zum Aktivieren oder Deaktivieren aller Ein- und Ausschaltverzögerungen.
7 30 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
8 29 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
9 28 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
10 24 4-bit UInteger 2 = Doppelbogen Auswertungstyp Auswertungstyp.
11 8 12-bit UInteger 0..4095 Verstärkung Verstärkungsfaktor des Analogverstärkers.
12 0 4-bit UInteger 1..15 Sendelänge Länge des Sendeimpulses in Einzelschwingungen.
Octet 0
bit offset 191 190 189 188 187 186 185 184
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 1
bit offset 183 182 181 180 179 178 177 176
subindex 2
Octet 2
bit offset 175 174 173 172 171 170 169 168
subindex 2
Octet 3
bit offset 167 166 165 164 163 162 161 160
subindex 2
Octet 4
bit offset 159 158 157 156 155 154 153 152
subindex 2
Octet 5
bit offset 151 150 149 148 147 146 145 144
subindex 2
Octet 6
bit offset 143 142 141 140 139 138 137 136
subindex 2
Octet 7
bit offset 135 134 133 132 131 130 129 128
subindex 2
Octet 8
bit offset 127 126 125 124 123 122 121 120
subindex 2
Octet 9
bit offset 119 118 117 116 115 114 113 112
subindex 2
Octet 10
bit offset 111 110 109 108 107 106 105 104
subindex 2
Octet 11
bit offset 103 102 101 100 99 98 97 96
subindex 2
Octet 12
bit offset 95 94 93 92 91 90 89 88
subindex 2
Octet 13
bit offset 87 86 85 84 83 82 81 80
subindex 2
Octet 14
bit offset 79 78 77 76 75 74 73 72
subindex / / / / / / / / / / / / / / / / / / / / / / / / 3
element bit         11 10 9 8
Octet 15
bit offset 71 70 69 68 67 66 65 64
subindex 3
element bit 7 6 5 4 3 2 1 0
Octet 16
bit offset 63 62 61 60 59 58 57 56
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4
element bit         11 10 9 8
Octet 17
bit offset 55 54 53 52 51 50 49 48
subindex 4
element bit 7 6 5 4 3 2 1 0
Octet 18
bit offset 47 46 45 44 43 42 41 40
subindex / / / / / / / / / / / / / / / / / / / / / / / / 5
element bit         11 10 9 8
Octet 19
bit offset 39 38 37 36 35 34 33 32
subindex 5
element bit 7 6 5 4 3 2 1 0
Octet 20
bit offset 31 30 29 28 27 26 25 24
subindex 6 7 8 9 10
element bit         3 2 1 0
Octet 21
bit offset 23 22 21 20 19 18 17 16
subindex / / / / / / / / / / / / / / / / / / / / / / / / 11
element bit         11 10 9 8
Octet 22
bit offset 15 14 13 12 11 10 9 8
subindex 11
element bit 7 6 5 4 3 2 1 0
Octet 23
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 12
element bit         3 2 1 0

Variable "Rezept" index=533 id=V_RezeptspeicherLV_Rezept4

description: Rezept für Messungen mit geringer Leistung.
data type: 192-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 184 8-bit UInteger CRC Checksumme des Rezepts. Bei manuellen Veränderungen wird ein Event als Warnung ausgegeben.
2 80 13-octet OctetString Reserviert Reserviert.
3 64 12-bit UInteger 0..4095 Reserviert Reserviert.
4 48 12-bit UInteger 0..4095 Reserviert Reserviert.
5 32 12-bit UInteger 0..4095 Schwellwert Doppelbogen Untere Schaltschwelle für Ausgabe Doppelbogen erkannt.
6 31 Boolean false = inaktiv, true = aktiv Ein- und Ausschaltverzögerung Flag zum Aktivieren oder Deaktivieren aller Ein- und Ausschaltverzögerungen.
7 30 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
8 29 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
9 28 Boolean false = inaktiv, true = aktiv Reserviert Reserviert.
10 24 4-bit UInteger 2 = Doppelbogen Auswertungstyp Auswertungstyp.
11 8 12-bit UInteger 0..4095 Verstärkung Verstärkungsfaktor des Analogverstärkers.
12 0 4-bit UInteger 1..15 Sendelänge Länge des Sendeimpulses in Einzelschwingungen.
Octet 0
bit offset 191 190 189 188 187 186 185 184
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 1
bit offset 183 182 181 180 179 178 177 176
subindex 2
Octet 2
bit offset 175 174 173 172 171 170 169 168
subindex 2
Octet 3
bit offset 167 166 165 164 163 162 161 160
subindex 2
Octet 4
bit offset 159 158 157 156 155 154 153 152
subindex 2
Octet 5
bit offset 151 150 149 148 147 146 145 144
subindex 2
Octet 6
bit offset 143 142 141 140 139 138 137 136
subindex 2
Octet 7
bit offset 135 134 133 132 131 130 129 128
subindex 2
Octet 8
bit offset 127 126 125 124 123 122 121 120
subindex 2
Octet 9
bit offset 119 118 117 116 115 114 113 112
subindex 2
Octet 10
bit offset 111 110 109 108 107 106 105 104
subindex 2
Octet 11
bit offset 103 102 101 100 99 98 97 96
subindex 2
Octet 12
bit offset 95 94 93 92 91 90 89 88
subindex 2
Octet 13
bit offset 87 86 85 84 83 82 81 80
subindex 2
Octet 14
bit offset 79 78 77 76 75 74 73 72
subindex / / / / / / / / / / / / / / / / / / / / / / / / 3
element bit         11 10 9 8
Octet 15
bit offset 71 70 69 68 67 66 65 64
subindex 3
element bit 7 6 5 4 3 2 1 0
Octet 16
bit offset 63 62 61 60 59 58 57 56
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4
element bit         11 10 9 8
Octet 17
bit offset 55 54 53 52 51 50 49 48
subindex 4
element bit 7 6 5 4 3 2 1 0
Octet 18
bit offset 47 46 45 44 43 42 41 40
subindex / / / / / / / / / / / / / / / / / / / / / / / / 5
element bit         11 10 9 8
Octet 19
bit offset 39 38 37 36 35 34 33 32
subindex 5
element bit 7 6 5 4 3 2 1 0
Octet 20
bit offset 31 30 29 28 27 26 25 24
subindex 6 7 8 9 10
element bit         3 2 1 0
Octet 21
bit offset 23 22 21 20 19 18 17 16
subindex / / / / / / / / / / / / / / / / / / / / / / / / 11
element bit         11 10 9 8
Octet 22
bit offset 15 14 13 12 11 10 9 8
subindex 11
element bit 7 6 5 4 3 2 1 0
Octet 23
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 12
element bit         3 2 1 0

Variable "Temperatur" index=2000 id=V_VENDOR_Temperature

description: Diagnosedaten der über die gesamte Laufzeit und aktuell aufgetretenen Temperaturen.
data type: 80-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 64 16-bit Integer -400..1050 0 Aktuelle Temperatur Aktuelle interne Sensortemperatur.
2 48 16-bit Integer 0 Max. Sensortemperatur allzeit Größte gemessene Sensortemperatur.
3 32 16-bit Integer 0 Min. Sensortemperatur allzeit Kleinste gemessene Sensortemperatur.
4 16 16-bit Integer 0 Max. Sensortemperatur seit letztem Reset Größte gemessene Sensortemperatur seit Reset.
5 0 16-bit Integer 0 Min. Sensortemperatur seit letztem Reset Kleinste gemessene Sensortemperatur seit Reset.

octet 0 1 2 3 4 5 6 7
bit offset 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16
subindex 1 1 2 2 3 3 4 4
element bit 15 - 8 7 - 0 15 - 8 7 - 0 15 - 8 7 - 0 15 - 8 7 - 0

octet 8 9  
bit offset 15 - 8 7 - 0  
subindex 5 5  
element bit 15 - 8 7 - 0  

Variable "Zykluszeiten" index=2001 id=V_DiagZeit

description: Zykluszeiten des Sensors.
data type: 32-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer 0 SIO-Modus Messzykluszeit in 10 µs im Freilauf Modus.
2 0 16-bit Integer 0 IO-Link IO-Link Cycletime in 10 µs.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 2 2  
element bit 15 - 8 7 - 0 15 - 8 7 - 0  

Variable "Teach-in" index=2002 id=V_DiagTeachin

description: Diagnosedaten zur zuletzt durchgeführten Teach-in Prozedur.
data type: 16-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 8 8-bit UInteger 0 = Standby, 1 = Läuft, 2 = Erfolgreich, 3 = Abbruch, 4 = Fehler, 5 = Fehler: Material, 6 = Fehler: Werte, 7 = Fehler: Fehlbogen 0 Status Erweiterte Rückmeldung der Teach-in Prozedur.

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 1 / / / / / /  
element bit 7 - 0    

Variable "Diagnose Laufzeit" index=2003 id=V_DiagLaufzeit

description: Diagnosedaten über die gesamte Laufzeit des Sensors.
data type: 144-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 112 32-bit UInteger 0 Betriebszeitzähler Gesamtbetriebszeit des Sensors in Minuten.
2 80 32-bit UInteger 0 Betriebszeitzähler seit Reset Betriebszeit des Sensors seit Reset in Minuten.
3 48 32-bit UInteger 0 Bootzyklen Anzahl aller Sensorstartzyklen.
4 16 32-bit UInteger 0 EEProm Schreibzyklen Anzahl aller Schreibzyklen auf das EEPROM.
5 0 16-bit UInteger 0 Fehleranzahl Anzahl aller ausgegebenen Fehlermeldungen.

octet 0 1 2 3 4 5 6 7
bit offset 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16
subindex 3 3 3 3 4 4 4 4
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17  
bit offset 15 - 8 7 - 0  
subindex 5 5  
element bit 15 - 8 7 - 0  

Variable "Diagnose Messung" index=2004 id=V_DiagMessung

description: Diagnosedaten zur Messung.
data type: 16-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 16-bit UInteger 0 Material Inhomogenität Beschreibt die Inhomogenität des abzutastenden Materials. Je höher der Zahlenwert, um so inhomogener die (akustischen) Materialeigenschaften.

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 1 1  
element bit 15 - 8 7 - 0  

Variable "Fehlerhistorie" index=2005 id=V_DiagFehlerHistorie

description: Auflistung der letzten 32 Fehler über die gesamte Laufzeit des Sensors.
data type: 1536-bit Record (subindex access not supported)
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 32-bit UInteger 0 Zeitpunkt[0] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
2 0 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[0] Fehlerbeschreibung.
3 64 32-bit UInteger 0 Zeitpunkt[1] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
4 48 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[1] Fehlerbeschreibung.
5 112 32-bit UInteger 0 Zeitpunkt[2] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
6 96 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[2] Fehlerbeschreibung.
7 160 32-bit UInteger 0 Zeitpunkt[3] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
8 144 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[3] Fehlerbeschreibung.
9 208 32-bit UInteger 0 Zeitpunkt[4] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
10 192 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[4] Fehlerbeschreibung.
11 256 32-bit UInteger 0 Zeitpunkt[5] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
12 240 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[5] Fehlerbeschreibung.
13 304 32-bit UInteger 0 Zeitpunkt[6] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
14 288 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[6] Fehlerbeschreibung.
15 352 32-bit UInteger 0 Zeitpunkt[7] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
16 336 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[7] Fehlerbeschreibung.
17 400 32-bit UInteger 0 Zeitpunkt[8] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
18 384 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[8] Fehlerbeschreibung.
19 448 32-bit UInteger 0 Zeitpunkt[9] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
20 432 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[9] Fehlerbeschreibung.
21 496 32-bit UInteger 0 Zeitpunkt[10] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
22 480 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[10] Fehlerbeschreibung.
23 544 32-bit UInteger 0 Zeitpunkt[11] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
24 528 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[11] Fehlerbeschreibung.
25 592 32-bit UInteger 0 Zeitpunkt[12] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
26 576 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[12] Fehlerbeschreibung.
27 640 32-bit UInteger 0 Zeitpunkt[13] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
28 624 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[13] Fehlerbeschreibung.
29 688 32-bit UInteger 0 Zeitpunkt[14] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
30 672 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[14] Fehlerbeschreibung.
31 736 32-bit UInteger 0 Zeitpunkt[15] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
32 720 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[15] Fehlerbeschreibung.
33 784 32-bit UInteger 0 Zeitpunkt[16] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
34 768 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[16] Fehlerbeschreibung.
35 832 32-bit UInteger 0 Zeitpunkt[17] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
36 816 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[17] Fehlerbeschreibung.
37 880 32-bit UInteger 0 Zeitpunkt[18] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
38 864 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[18] Fehlerbeschreibung.
39 928 32-bit UInteger 0 Zeitpunkt[19] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
40 912 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[19] Fehlerbeschreibung.
41 976 32-bit UInteger 0 Zeitpunkt[20] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
42 960 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[20] Fehlerbeschreibung.
43 1024 32-bit UInteger 0 Zeitpunkt[21] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
44 1008 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[21] Fehlerbeschreibung.
45 1072 32-bit UInteger 0 Zeitpunkt[22] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
46 1056 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[22] Fehlerbeschreibung.
47 1120 32-bit UInteger 0 Zeitpunkt[23] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
48 1104 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[23] Fehlerbeschreibung.
49 1168 32-bit UInteger 0 Zeitpunkt[24] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
50 1152 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[24] Fehlerbeschreibung.
51 1216 32-bit UInteger 0 Zeitpunkt[25] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
52 1200 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[25] Fehlerbeschreibung.
53 1264 32-bit UInteger 0 Zeitpunkt[26] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
54 1248 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[26] Fehlerbeschreibung.
55 1312 32-bit UInteger 0 Zeitpunkt[27] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
56 1296 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[27] Fehlerbeschreibung.
57 1360 32-bit UInteger 0 Zeitpunkt[28] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
58 1344 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[28] Fehlerbeschreibung.
59 1408 32-bit UInteger 0 Zeitpunkt[29] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
60 1392 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[29] Fehlerbeschreibung.
61 1456 32-bit UInteger 0 Zeitpunkt[30] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
62 1440 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[30] Fehlerbeschreibung.
63 1504 32-bit UInteger 0 Zeitpunkt[31] Wert des Betriebszeitzählers zum Zeitpunkt des Auftreten des Fehlers.
64 1488 16-bit UInteger 0 = Leer, 16384 = Übertemperatur, 20736 = Versorgungsspannung zu gering, 30480 = Kurzschluss 0 Beschreibung[31] Fehlerbeschreibung.

octet 0 1 2 3 4 5 6 7
bit offset 1535 - 1528 1527 - 1520 1519 - 1512 1511 - 1504 1503 - 1496 1495 - 1488 1487 - 1480 1479 - 1472
subindex 63 63 63 63 64 64 61 61
element bit 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16

octet 8 9 10 11 12 13 14 15
bit offset 1471 - 1464 1463 - 1456 1455 - 1448 1447 - 1440 1439 - 1432 1431 - 1424 1423 - 1416 1415 - 1408
subindex 61 61 62 62 59 59 59 59
element bit 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 16 17 18 19 20 21 22 23
bit offset 1407 - 1400 1399 - 1392 1391 - 1384 1383 - 1376 1375 - 1368 1367 - 1360 1359 - 1352 1351 - 1344
subindex 60 60 57 57 57 57 58 58
element bit 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0

octet 24 25 26 27 28 29 30 31
bit offset 1343 - 1336 1335 - 1328 1327 - 1320 1319 - 1312 1311 - 1304 1303 - 1296 1295 - 1288 1287 - 1280
subindex 55 55 55 55 56 56 53 53
element bit 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16

octet 32 33 34 35 36 37 38 39
bit offset 1279 - 1272 1271 - 1264 1263 - 1256 1255 - 1248 1247 - 1240 1239 - 1232 1231 - 1224 1223 - 1216
subindex 53 53 54 54 51 51 51 51
element bit 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 40 41 42 43 44 45 46 47
bit offset 1215 - 1208 1207 - 1200 1199 - 1192 1191 - 1184 1183 - 1176 1175 - 1168 1167 - 1160 1159 - 1152
subindex 52 52 49 49 49 49 50 50
element bit 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0

octet 48 49 50 51 52 53 54 55
bit offset 1151 - 1144 1143 - 1136 1135 - 1128 1127 - 1120 1119 - 1112 1111 - 1104 1103 - 1096 1095 - 1088
subindex 47 47 47 47 48 48 45 45
element bit 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16

octet 56 57 58 59 60 61 62 63
bit offset 1087 - 1080 1079 - 1072 1071 - 1064 1063 - 1056 1055 - 1048 1047 - 1040 1039 - 1032 1031 - 1024
subindex 45 45 46 46 43 43 43 43
element bit 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 64 65 66 67 68 69 70 71
bit offset 1023 - 1016 1015 - 1008 1007 - 1000 999 - 992 991 - 984 983 - 976 975 - 968 967 - 960
subindex 44 44 41 41 41 41 42 42
element bit 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0

octet 72 73 74 75 76 77 78 79
bit offset 959 - 952 951 - 944 943 - 936 935 - 928 927 - 920 919 - 912 911 - 904 903 - 896
subindex 39 39 39 39 40 40 37 37
element bit 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16

octet 80 81 82 83 84 85 86 87
bit offset 895 - 888 887 - 880 879 - 872 871 - 864 863 - 856 855 - 848 847 - 840 839 - 832
subindex 37 37 38 38 35 35 35 35
element bit 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 88 89 90 91 92 93 94 95
bit offset 831 - 824 823 - 816 815 - 808 807 - 800 799 - 792 791 - 784 783 - 776 775 - 768
subindex 36 36 33 33 33 33 34 34
element bit 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0

octet 96 97 98 99 100 101 102 103
bit offset 767 - 760 759 - 752 751 - 744 743 - 736 735 - 728 727 - 720 719 - 712 711 - 704
subindex 31 31 31 31 32 32 29 29
element bit 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16

octet 104 105 106 107 108 109 110 111
bit offset 703 - 696 695 - 688 687 - 680 679 - 672 671 - 664 663 - 656 655 - 648 647 - 640
subindex 29 29 30 30 27 27 27 27
element bit 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 112 113 114 115 116 117 118 119
bit offset 639 - 632 631 - 624 623 - 616 615 - 608 607 - 600 599 - 592 591 - 584 583 - 576
subindex 28 28 25 25 25 25 26 26
element bit 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0

octet 120 121 122 123 124 125 126 127
bit offset 575 - 568 567 - 560 559 - 552 551 - 544 543 - 536 535 - 528 527 - 520 519 - 512
subindex 23 23 23 23 24 24 21 21
element bit 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16

octet 128 129 130 131 132 133 134 135
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448
subindex 21 21 22 22 19 19 19 19
element bit 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 136 137 138 139 140 141 142 143
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384
subindex 20 20 17 17 17 17 18 18
element bit 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0

octet 144 145 146 147 148 149 150 151
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320
subindex 15 15 15 15 16 16 13 13
element bit 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16

octet 152 153 154 155 156 157 158 159
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256
subindex 13 13 14 14 11 11 11 11
element bit 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 160 161 162 163 164 165 166 167
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192
subindex 12 12 9 9 9 9 10 10
element bit 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0

octet 168 169 170 171 172 173 174 175
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128
subindex 7 7 7 7 8 8 5 5
element bit 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16

octet 176 177 178 179 180 181 182 183
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 5 5 6 6 3 3 3 3
element bit 15 - 8 7 - 0 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 184 185 186 187 188 189 190 191
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 4 4 1 1 1 1 2 2
element bit 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0 15 - 8 7 - 0

Variable "Zählwerk" index=2006 id=V_DiagCounter

description: Flüchtiges Zählwerk zur Auswertung der aufgetretenen Zustände seit Zuschalten der Versorgungsspannung.
data type: 128-bit Record
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 96 32-bit UInteger 0 Einzelbogen Anzahl aufgetretener Zustandswechsel zum Zustand Einzelbogen seit Zuschalten der Versorgungspannung.
2 64 32-bit UInteger 0 Doppelbogen Anzahl aufgetretener Zustandswechsel zum Zustand Doppelbogen seit Zuschalten der Versorgungspannung.
3 32 32-bit UInteger 0 Übersteuerung Anzahl aufgetretener Zustandswechsel zum Zustand Übersteuerung seit Zuschalten der Versorgungspannung.
4 0 32-bit UInteger 0 Fehlbogen Anzahl aufgetretener Zustandswechsel zum Zustand Fehlbogen seit Zuschalten der Versorgungspannung.

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 3 3 3 3 4 4 4 4
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Aktueller Sensorzustand" index=2007 id=V_DiagZusammenfassung

description: Diagnosedaten zum aktuellen Sensorzustand.
data type: 56-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 40 16-bit UInteger 0 Messwert Aktueller Messwert des internen Signalverstärkers.
2 32 8-bit UInteger 0 = Low, 1 = High 0 Ausgang D1 Aktueller Schaltzustand von Schaltausgang D1.
3 24 8-bit UInteger 0 = Low, 1 = High 0 Ausgang D2 Aktueller Schaltzustand von Schaltausgang D2.
4 16 8-bit UInteger 0 = n.c., 1 = Low, 2 = High 0 Eingang C1 Aktueller Signalpegel an Steuereingang C1.
5 8 8-bit UInteger 0 = n.c., 1 = Low, 2 = High 0 Eingang C2 Aktueller Signalpegel an Steuereingang C2.
6 0 8-bit UInteger 0 = n.c., 1 = Low, 2 = High 0 Eingang C3 Aktueller Signalpegel an Steuereingang C3.

octet 0 1 2 3 4 5 6  
bit offset 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 2 3 4 5 6  
element bit 15 - 8 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0  

Variable "Messwertaufzeichnung Konfiguration" index=2020 id=V_HistogrammConfig

description: Konfiguration der Messwertaufzeichnung.
data type: 40-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 8-bit UInteger 0 = inaktiv, 1 = Messdaten ab einem Trigger aufzeichnen 0 Modus Messwertaufzeichnung ein-/ausschalten.
2 24 8-bit UInteger 0 = inaktiv, 1 = Doppelbogen, 2 = IO-Link Systemkommando Trigger 0 Trigger Auswahl der Triggerquelle.
3 16 8-bit UInteger 0 = inaktiv, 1 = aktiv 0 Event senden Flag für Event senden, wenn die Messwerteaufzeichnung abgeschlossen ist.
4 0 16-bit Integer 1..999 100 Post-Trigger Länge der Aufzeichnung nach Triggerereignis.

octet 0 1 2 3 4  
bit offset 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 2 3 4 4  
element bit 7 - 0 7 - 0 7 - 0 15 - 8 7 - 0  

Variable "Messwertaufzeichnung Kopf" index=2021 id=V_HistogrammPufferHeader

description: Metadaten zu den gespeicherten Elementen im Ringpuffer.
data type: 16-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 16-bit Integer 0..1000 0 Zeiger Ringpuffer Startpunkt der Messwertaufzeichnung im Ringpuffer.

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 1 1  
element bit 15 - 8 7 - 0  

Variable "Messwertaufzeichnung Ringpuffer 1" index=2022 id=V_HistogrammPuffer1

description: Dieses Element enthält die Elemente 0...99 des Ringpuffers der Messwertaufzeichnung.
data type: 200-octet OctetString
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 1599 - 1592 1591 - 1584 1583 - 1576 1575 - 1568 1567 - 1560 1559 - 1552 1551 - 1544 1543 - 1536

octet 8 9 10 11 12 13 14 15
bit offset 1535 - 1528 1527 - 1520 1519 - 1512 1511 - 1504 1503 - 1496 1495 - 1488 1487 - 1480 1479 - 1472

octet 16 17 18 19 20 21 22 23
bit offset 1471 - 1464 1463 - 1456 1455 - 1448 1447 - 1440 1439 - 1432 1431 - 1424 1423 - 1416 1415 - 1408

octet 24 25 26 27 28 29 30 31
bit offset 1407 - 1400 1399 - 1392 1391 - 1384 1383 - 1376 1375 - 1368 1367 - 1360 1359 - 1352 1351 - 1344

octet 32 33 34 35 36 37 38 39
bit offset 1343 - 1336 1335 - 1328 1327 - 1320 1319 - 1312 1311 - 1304 1303 - 1296 1295 - 1288 1287 - 1280

octet 40 41 42 43 44 45 46 47
bit offset 1279 - 1272 1271 - 1264 1263 - 1256 1255 - 1248 1247 - 1240 1239 - 1232 1231 - 1224 1223 - 1216

octet 48 49 50 51 52 53 54 55
bit offset 1215 - 1208 1207 - 1200 1199 - 1192 1191 - 1184 1183 - 1176 1175 - 1168 1167 - 1160 1159 - 1152

octet 56 57 58 59 60 61 62 63
bit offset 1151 - 1144 1143 - 1136 1135 - 1128 1127 - 1120 1119 - 1112 1111 - 1104 1103 - 1096 1095 - 1088

octet 64 65 66 67 68 69 70 71
bit offset 1087 - 1080 1079 - 1072 1071 - 1064 1063 - 1056 1055 - 1048 1047 - 1040 1039 - 1032 1031 - 1024

octet 72 73 74 75 76 77 78 79
bit offset 1023 - 1016 1015 - 1008 1007 - 1000 999 - 992 991 - 984 983 - 976 975 - 968 967 - 960

octet 80 81 82 83 84 85 86 87
bit offset 959 - 952 951 - 944 943 - 936 935 - 928 927 - 920 919 - 912 911 - 904 903 - 896

octet 88 89 90 91 92 93 94 95
bit offset 895 - 888 887 - 880 879 - 872 871 - 864 863 - 856 855 - 848 847 - 840 839 - 832

octet 96 97 98 99 100 101 102 103
bit offset 831 - 824 823 - 816 815 - 808 807 - 800 799 - 792 791 - 784 783 - 776 775 - 768

octet 104 105 106 107 108 109 110 111
bit offset 767 - 760 759 - 752 751 - 744 743 - 736 735 - 728 727 - 720 719 - 712 711 - 704

octet 112 113 114 115 116 117 118 119
bit offset 703 - 696 695 - 688 687 - 680 679 - 672 671 - 664 663 - 656 655 - 648 647 - 640

octet 120 121 122 123 124 125 126 127
bit offset 639 - 632 631 - 624 623 - 616 615 - 608 607 - 600 599 - 592 591 - 584 583 - 576

octet 128 129 130 131 132 133 134 135
bit offset 575 - 568 567 - 560 559 - 552 551 - 544 543 - 536 535 - 528 527 - 520 519 - 512

octet 136 137 138 139 140 141 142 143
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 144 145 146 147 148 149 150 151
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 152 153 154 155 156 157 158 159
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 160 161 162 163 164 165 166 167
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 168 169 170 171 172 173 174 175
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 176 177 178 179 180 181 182 183
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 184 185 186 187 188 189 190 191
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 192 193 194 195 196 197 198 199
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Messwertaufzeichnung Ringpuffer 2" index=2023 id=V_HistogrammPuffer2

description: Dieses Element enthält die Elemente 100...199 des Ringpuffers der Messwertaufzeichnung.
data type: 200-octet OctetString
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 1599 - 1592 1591 - 1584 1583 - 1576 1575 - 1568 1567 - 1560 1559 - 1552 1551 - 1544 1543 - 1536

octet 8 9 10 11 12 13 14 15
bit offset 1535 - 1528 1527 - 1520 1519 - 1512 1511 - 1504 1503 - 1496 1495 - 1488 1487 - 1480 1479 - 1472

octet 16 17 18 19 20 21 22 23
bit offset 1471 - 1464 1463 - 1456 1455 - 1448 1447 - 1440 1439 - 1432 1431 - 1424 1423 - 1416 1415 - 1408

octet 24 25 26 27 28 29 30 31
bit offset 1407 - 1400 1399 - 1392 1391 - 1384 1383 - 1376 1375 - 1368 1367 - 1360 1359 - 1352 1351 - 1344

octet 32 33 34 35 36 37 38 39
bit offset 1343 - 1336 1335 - 1328 1327 - 1320 1319 - 1312 1311 - 1304 1303 - 1296 1295 - 1288 1287 - 1280

octet 40 41 42 43 44 45 46 47
bit offset 1279 - 1272 1271 - 1264 1263 - 1256 1255 - 1248 1247 - 1240 1239 - 1232 1231 - 1224 1223 - 1216

octet 48 49 50 51 52 53 54 55
bit offset 1215 - 1208 1207 - 1200 1199 - 1192 1191 - 1184 1183 - 1176 1175 - 1168 1167 - 1160 1159 - 1152

octet 56 57 58 59 60 61 62 63
bit offset 1151 - 1144 1143 - 1136 1135 - 1128 1127 - 1120 1119 - 1112 1111 - 1104 1103 - 1096 1095 - 1088

octet 64 65 66 67 68 69 70 71
bit offset 1087 - 1080 1079 - 1072 1071 - 1064 1063 - 1056 1055 - 1048 1047 - 1040 1039 - 1032 1031 - 1024

octet 72 73 74 75 76 77 78 79
bit offset 1023 - 1016 1015 - 1008 1007 - 1000 999 - 992 991 - 984 983 - 976 975 - 968 967 - 960

octet 80 81 82 83 84 85 86 87
bit offset 959 - 952 951 - 944 943 - 936 935 - 928 927 - 920 919 - 912 911 - 904 903 - 896

octet 88 89 90 91 92 93 94 95
bit offset 895 - 888 887 - 880 879 - 872 871 - 864 863 - 856 855 - 848 847 - 840 839 - 832

octet 96 97 98 99 100 101 102 103
bit offset 831 - 824 823 - 816 815 - 808 807 - 800 799 - 792 791 - 784 783 - 776 775 - 768

octet 104 105 106 107 108 109 110 111
bit offset 767 - 760 759 - 752 751 - 744 743 - 736 735 - 728 727 - 720 719 - 712 711 - 704

octet 112 113 114 115 116 117 118 119
bit offset 703 - 696 695 - 688 687 - 680 679 - 672 671 - 664 663 - 656 655 - 648 647 - 640

octet 120 121 122 123 124 125 126 127
bit offset 639 - 632 631 - 624 623 - 616 615 - 608 607 - 600 599 - 592 591 - 584 583 - 576

octet 128 129 130 131 132 133 134 135
bit offset 575 - 568 567 - 560 559 - 552 551 - 544 543 - 536 535 - 528 527 - 520 519 - 512

octet 136 137 138 139 140 141 142 143
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 144 145 146 147 148 149 150 151
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 152 153 154 155 156 157 158 159
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 160 161 162 163 164 165 166 167
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 168 169 170 171 172 173 174 175
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 176 177 178 179 180 181 182 183
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 184 185 186 187 188 189 190 191
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 192 193 194 195 196 197 198 199
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Messwertaufzeichnung Ringpuffer 3" index=2024 id=V_HistogrammPuffer3

description: Dieses Element enthält die Elemente 200...299 des Ringpuffers der Messwertaufzeichnung.
data type: 200-octet OctetString
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 1599 - 1592 1591 - 1584 1583 - 1576 1575 - 1568 1567 - 1560 1559 - 1552 1551 - 1544 1543 - 1536

octet 8 9 10 11 12 13 14 15
bit offset 1535 - 1528 1527 - 1520 1519 - 1512 1511 - 1504 1503 - 1496 1495 - 1488 1487 - 1480 1479 - 1472

octet 16 17 18 19 20 21 22 23
bit offset 1471 - 1464 1463 - 1456 1455 - 1448 1447 - 1440 1439 - 1432 1431 - 1424 1423 - 1416 1415 - 1408

octet 24 25 26 27 28 29 30 31
bit offset 1407 - 1400 1399 - 1392 1391 - 1384 1383 - 1376 1375 - 1368 1367 - 1360 1359 - 1352 1351 - 1344

octet 32 33 34 35 36 37 38 39
bit offset 1343 - 1336 1335 - 1328 1327 - 1320 1319 - 1312 1311 - 1304 1303 - 1296 1295 - 1288 1287 - 1280

octet 40 41 42 43 44 45 46 47
bit offset 1279 - 1272 1271 - 1264 1263 - 1256 1255 - 1248 1247 - 1240 1239 - 1232 1231 - 1224 1223 - 1216

octet 48 49 50 51 52 53 54 55
bit offset 1215 - 1208 1207 - 1200 1199 - 1192 1191 - 1184 1183 - 1176 1175 - 1168 1167 - 1160 1159 - 1152

octet 56 57 58 59 60 61 62 63
bit offset 1151 - 1144 1143 - 1136 1135 - 1128 1127 - 1120 1119 - 1112 1111 - 1104 1103 - 1096 1095 - 1088

octet 64 65 66 67 68 69 70 71
bit offset 1087 - 1080 1079 - 1072 1071 - 1064 1063 - 1056 1055 - 1048 1047 - 1040 1039 - 1032 1031 - 1024

octet 72 73 74 75 76 77 78 79
bit offset 1023 - 1016 1015 - 1008 1007 - 1000 999 - 992 991 - 984 983 - 976 975 - 968 967 - 960

octet 80 81 82 83 84 85 86 87
bit offset 959 - 952 951 - 944 943 - 936 935 - 928 927 - 920 919 - 912 911 - 904 903 - 896

octet 88 89 90 91 92 93 94 95
bit offset 895 - 888 887 - 880 879 - 872 871 - 864 863 - 856 855 - 848 847 - 840 839 - 832

octet 96 97 98 99 100 101 102 103
bit offset 831 - 824 823 - 816 815 - 808 807 - 800 799 - 792 791 - 784 783 - 776 775 - 768

octet 104 105 106 107 108 109 110 111
bit offset 767 - 760 759 - 752 751 - 744 743 - 736 735 - 728 727 - 720 719 - 712 711 - 704

octet 112 113 114 115 116 117 118 119
bit offset 703 - 696 695 - 688 687 - 680 679 - 672 671 - 664 663 - 656 655 - 648 647 - 640

octet 120 121 122 123 124 125 126 127
bit offset 639 - 632 631 - 624 623 - 616 615 - 608 607 - 600 599 - 592 591 - 584 583 - 576

octet 128 129 130 131 132 133 134 135
bit offset 575 - 568 567 - 560 559 - 552 551 - 544 543 - 536 535 - 528 527 - 520 519 - 512

octet 136 137 138 139 140 141 142 143
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 144 145 146 147 148 149 150 151
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 152 153 154 155 156 157 158 159
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 160 161 162 163 164 165 166 167
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 168 169 170 171 172 173 174 175
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 176 177 178 179 180 181 182 183
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 184 185 186 187 188 189 190 191
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 192 193 194 195 196 197 198 199
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Messwertaufzeichnung Ringpuffer 4" index=2025 id=V_HistogrammPuffer4

description: Dieses Element enthält die Elemente 300...399 des Ringpuffers der Messwertaufzeichnung.
data type: 200-octet OctetString
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 1599 - 1592 1591 - 1584 1583 - 1576 1575 - 1568 1567 - 1560 1559 - 1552 1551 - 1544 1543 - 1536

octet 8 9 10 11 12 13 14 15
bit offset 1535 - 1528 1527 - 1520 1519 - 1512 1511 - 1504 1503 - 1496 1495 - 1488 1487 - 1480 1479 - 1472

octet 16 17 18 19 20 21 22 23
bit offset 1471 - 1464 1463 - 1456 1455 - 1448 1447 - 1440 1439 - 1432 1431 - 1424 1423 - 1416 1415 - 1408

octet 24 25 26 27 28 29 30 31
bit offset 1407 - 1400 1399 - 1392 1391 - 1384 1383 - 1376 1375 - 1368 1367 - 1360 1359 - 1352 1351 - 1344

octet 32 33 34 35 36 37 38 39
bit offset 1343 - 1336 1335 - 1328 1327 - 1320 1319 - 1312 1311 - 1304 1303 - 1296 1295 - 1288 1287 - 1280

octet 40 41 42 43 44 45 46 47
bit offset 1279 - 1272 1271 - 1264 1263 - 1256 1255 - 1248 1247 - 1240 1239 - 1232 1231 - 1224 1223 - 1216

octet 48 49 50 51 52 53 54 55
bit offset 1215 - 1208 1207 - 1200 1199 - 1192 1191 - 1184 1183 - 1176 1175 - 1168 1167 - 1160 1159 - 1152

octet 56 57 58 59 60 61 62 63
bit offset 1151 - 1144 1143 - 1136 1135 - 1128 1127 - 1120 1119 - 1112 1111 - 1104 1103 - 1096 1095 - 1088

octet 64 65 66 67 68 69 70 71
bit offset 1087 - 1080 1079 - 1072 1071 - 1064 1063 - 1056 1055 - 1048 1047 - 1040 1039 - 1032 1031 - 1024

octet 72 73 74 75 76 77 78 79
bit offset 1023 - 1016 1015 - 1008 1007 - 1000 999 - 992 991 - 984 983 - 976 975 - 968 967 - 960

octet 80 81 82 83 84 85 86 87
bit offset 959 - 952 951 - 944 943 - 936 935 - 928 927 - 920 919 - 912 911 - 904 903 - 896

octet 88 89 90 91 92 93 94 95
bit offset 895 - 888 887 - 880 879 - 872 871 - 864 863 - 856 855 - 848 847 - 840 839 - 832

octet 96 97 98 99 100 101 102 103
bit offset 831 - 824 823 - 816 815 - 808 807 - 800 799 - 792 791 - 784 783 - 776 775 - 768

octet 104 105 106 107 108 109 110 111
bit offset 767 - 760 759 - 752 751 - 744 743 - 736 735 - 728 727 - 720 719 - 712 711 - 704

octet 112 113 114 115 116 117 118 119
bit offset 703 - 696 695 - 688 687 - 680 679 - 672 671 - 664 663 - 656 655 - 648 647 - 640

octet 120 121 122 123 124 125 126 127
bit offset 639 - 632 631 - 624 623 - 616 615 - 608 607 - 600 599 - 592 591 - 584 583 - 576

octet 128 129 130 131 132 133 134 135
bit offset 575 - 568 567 - 560 559 - 552 551 - 544 543 - 536 535 - 528 527 - 520 519 - 512

octet 136 137 138 139 140 141 142 143
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 144 145 146 147 148 149 150 151
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 152 153 154 155 156 157 158 159
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 160 161 162 163 164 165 166 167
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 168 169 170 171 172 173 174 175
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 176 177 178 179 180 181 182 183
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 184 185 186 187 188 189 190 191
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 192 193 194 195 196 197 198 199
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Messwertaufzeichnung Ringpuffer 5" index=2026 id=V_HistogrammPuffer5

description: Dieses Element enthält die Elemente 400...499 des Ringpuffers der Messwertaufzeichnung.
data type: 200-octet OctetString
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 1599 - 1592 1591 - 1584 1583 - 1576 1575 - 1568 1567 - 1560 1559 - 1552 1551 - 1544 1543 - 1536

octet 8 9 10 11 12 13 14 15
bit offset 1535 - 1528 1527 - 1520 1519 - 1512 1511 - 1504 1503 - 1496 1495 - 1488 1487 - 1480 1479 - 1472

octet 16 17 18 19 20 21 22 23
bit offset 1471 - 1464 1463 - 1456 1455 - 1448 1447 - 1440 1439 - 1432 1431 - 1424 1423 - 1416 1415 - 1408

octet 24 25 26 27 28 29 30 31
bit offset 1407 - 1400 1399 - 1392 1391 - 1384 1383 - 1376 1375 - 1368 1367 - 1360 1359 - 1352 1351 - 1344

octet 32 33 34 35 36 37 38 39
bit offset 1343 - 1336 1335 - 1328 1327 - 1320 1319 - 1312 1311 - 1304 1303 - 1296 1295 - 1288 1287 - 1280

octet 40 41 42 43 44 45 46 47
bit offset 1279 - 1272 1271 - 1264 1263 - 1256 1255 - 1248 1247 - 1240 1239 - 1232 1231 - 1224 1223 - 1216

octet 48 49 50 51 52 53 54 55
bit offset 1215 - 1208 1207 - 1200 1199 - 1192 1191 - 1184 1183 - 1176 1175 - 1168 1167 - 1160 1159 - 1152

octet 56 57 58 59 60 61 62 63
bit offset 1151 - 1144 1143 - 1136 1135 - 1128 1127 - 1120 1119 - 1112 1111 - 1104 1103 - 1096 1095 - 1088

octet 64 65 66 67 68 69 70 71
bit offset 1087 - 1080 1079 - 1072 1071 - 1064 1063 - 1056 1055 - 1048 1047 - 1040 1039 - 1032 1031 - 1024

octet 72 73 74 75 76 77 78 79
bit offset 1023 - 1016 1015 - 1008 1007 - 1000 999 - 992 991 - 984 983 - 976 975 - 968 967 - 960

octet 80 81 82 83 84 85 86 87
bit offset 959 - 952 951 - 944 943 - 936 935 - 928 927 - 920 919 - 912 911 - 904 903 - 896

octet 88 89 90 91 92 93 94 95
bit offset 895 - 888 887 - 880 879 - 872 871 - 864 863 - 856 855 - 848 847 - 840 839 - 832

octet 96 97 98 99 100 101 102 103
bit offset 831 - 824 823 - 816 815 - 808 807 - 800 799 - 792 791 - 784 783 - 776 775 - 768

octet 104 105 106 107 108 109 110 111
bit offset 767 - 760 759 - 752 751 - 744 743 - 736 735 - 728 727 - 720 719 - 712 711 - 704

octet 112 113 114 115 116 117 118 119
bit offset 703 - 696 695 - 688 687 - 680 679 - 672 671 - 664 663 - 656 655 - 648 647 - 640

octet 120 121 122 123 124 125 126 127
bit offset 639 - 632 631 - 624 623 - 616 615 - 608 607 - 600 599 - 592 591 - 584 583 - 576

octet 128 129 130 131 132 133 134 135
bit offset 575 - 568 567 - 560 559 - 552 551 - 544 543 - 536 535 - 528 527 - 520 519 - 512

octet 136 137 138 139 140 141 142 143
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 144 145 146 147 148 149 150 151
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 152 153 154 155 156 157 158 159
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 160 161 162 163 164 165 166 167
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 168 169 170 171 172 173 174 175
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 176 177 178 179 180 181 182 183
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 184 185 186 187 188 189 190 191
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 192 193 194 195 196 197 198 199
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Messwertaufzeichnung Ringpuffer 6" index=2027 id=V_HistogrammPuffer6

description: Dieses Element enthält die Elemente 500...599 des Ringpuffers der Messwertaufzeichnung.
data type: 200-octet OctetString
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 1599 - 1592 1591 - 1584 1583 - 1576 1575 - 1568 1567 - 1560 1559 - 1552 1551 - 1544 1543 - 1536

octet 8 9 10 11 12 13 14 15
bit offset 1535 - 1528 1527 - 1520 1519 - 1512 1511 - 1504 1503 - 1496 1495 - 1488 1487 - 1480 1479 - 1472

octet 16 17 18 19 20 21 22 23
bit offset 1471 - 1464 1463 - 1456 1455 - 1448 1447 - 1440 1439 - 1432 1431 - 1424 1423 - 1416 1415 - 1408

octet 24 25 26 27 28 29 30 31
bit offset 1407 - 1400 1399 - 1392 1391 - 1384 1383 - 1376 1375 - 1368 1367 - 1360 1359 - 1352 1351 - 1344

octet 32 33 34 35 36 37 38 39
bit offset 1343 - 1336 1335 - 1328 1327 - 1320 1319 - 1312 1311 - 1304 1303 - 1296 1295 - 1288 1287 - 1280

octet 40 41 42 43 44 45 46 47
bit offset 1279 - 1272 1271 - 1264 1263 - 1256 1255 - 1248 1247 - 1240 1239 - 1232 1231 - 1224 1223 - 1216

octet 48 49 50 51 52 53 54 55
bit offset 1215 - 1208 1207 - 1200 1199 - 1192 1191 - 1184 1183 - 1176 1175 - 1168 1167 - 1160 1159 - 1152

octet 56 57 58 59 60 61 62 63
bit offset 1151 - 1144 1143 - 1136 1135 - 1128 1127 - 1120 1119 - 1112 1111 - 1104 1103 - 1096 1095 - 1088

octet 64 65 66 67 68 69 70 71
bit offset 1087 - 1080 1079 - 1072 1071 - 1064 1063 - 1056 1055 - 1048 1047 - 1040 1039 - 1032 1031 - 1024

octet 72 73 74 75 76 77 78 79
bit offset 1023 - 1016 1015 - 1008 1007 - 1000 999 - 992 991 - 984 983 - 976 975 - 968 967 - 960

octet 80 81 82 83 84 85 86 87
bit offset 959 - 952 951 - 944 943 - 936 935 - 928 927 - 920 919 - 912 911 - 904 903 - 896

octet 88 89 90 91 92 93 94 95
bit offset 895 - 888 887 - 880 879 - 872 871 - 864 863 - 856 855 - 848 847 - 840 839 - 832

octet 96 97 98 99 100 101 102 103
bit offset 831 - 824 823 - 816 815 - 808 807 - 800 799 - 792 791 - 784 783 - 776 775 - 768

octet 104 105 106 107 108 109 110 111
bit offset 767 - 760 759 - 752 751 - 744 743 - 736 735 - 728 727 - 720 719 - 712 711 - 704

octet 112 113 114 115 116 117 118 119
bit offset 703 - 696 695 - 688 687 - 680 679 - 672 671 - 664 663 - 656 655 - 648 647 - 640

octet 120 121 122 123 124 125 126 127
bit offset 639 - 632 631 - 624 623 - 616 615 - 608 607 - 600 599 - 592 591 - 584 583 - 576

octet 128 129 130 131 132 133 134 135
bit offset 575 - 568 567 - 560 559 - 552 551 - 544 543 - 536 535 - 528 527 - 520 519 - 512

octet 136 137 138 139 140 141 142 143
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 144 145 146 147 148 149 150 151
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 152 153 154 155 156 157 158 159
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 160 161 162 163 164 165 166 167
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 168 169 170 171 172 173 174 175
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 176 177 178 179 180 181 182 183
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 184 185 186 187 188 189 190 191
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 192 193 194 195 196 197 198 199
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Messwertaufzeichnung Ringpuffer 7" index=2028 id=V_HistogrammPuffer7

description: Dieses Element enthält die Elemente 600...699 des Ringpuffers der Messwertaufzeichnung.
data type: 200-octet OctetString
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 1599 - 1592 1591 - 1584 1583 - 1576 1575 - 1568 1567 - 1560 1559 - 1552 1551 - 1544 1543 - 1536

octet 8 9 10 11 12 13 14 15
bit offset 1535 - 1528 1527 - 1520 1519 - 1512 1511 - 1504 1503 - 1496 1495 - 1488 1487 - 1480 1479 - 1472

octet 16 17 18 19 20 21 22 23
bit offset 1471 - 1464 1463 - 1456 1455 - 1448 1447 - 1440 1439 - 1432 1431 - 1424 1423 - 1416 1415 - 1408

octet 24 25 26 27 28 29 30 31
bit offset 1407 - 1400 1399 - 1392 1391 - 1384 1383 - 1376 1375 - 1368 1367 - 1360 1359 - 1352 1351 - 1344

octet 32 33 34 35 36 37 38 39
bit offset 1343 - 1336 1335 - 1328 1327 - 1320 1319 - 1312 1311 - 1304 1303 - 1296 1295 - 1288 1287 - 1280

octet 40 41 42 43 44 45 46 47
bit offset 1279 - 1272 1271 - 1264 1263 - 1256 1255 - 1248 1247 - 1240 1239 - 1232 1231 - 1224 1223 - 1216

octet 48 49 50 51 52 53 54 55
bit offset 1215 - 1208 1207 - 1200 1199 - 1192 1191 - 1184 1183 - 1176 1175 - 1168 1167 - 1160 1159 - 1152

octet 56 57 58 59 60 61 62 63
bit offset 1151 - 1144 1143 - 1136 1135 - 1128 1127 - 1120 1119 - 1112 1111 - 1104 1103 - 1096 1095 - 1088

octet 64 65 66 67 68 69 70 71
bit offset 1087 - 1080 1079 - 1072 1071 - 1064 1063 - 1056 1055 - 1048 1047 - 1040 1039 - 1032 1031 - 1024

octet 72 73 74 75 76 77 78 79
bit offset 1023 - 1016 1015 - 1008 1007 - 1000 999 - 992 991 - 984 983 - 976 975 - 968 967 - 960

octet 80 81 82 83 84 85 86 87
bit offset 959 - 952 951 - 944 943 - 936 935 - 928 927 - 920 919 - 912 911 - 904 903 - 896

octet 88 89 90 91 92 93 94 95
bit offset 895 - 888 887 - 880 879 - 872 871 - 864 863 - 856 855 - 848 847 - 840 839 - 832

octet 96 97 98 99 100 101 102 103
bit offset 831 - 824 823 - 816 815 - 808 807 - 800 799 - 792 791 - 784 783 - 776 775 - 768

octet 104 105 106 107 108 109 110 111
bit offset 767 - 760 759 - 752 751 - 744 743 - 736 735 - 728 727 - 720 719 - 712 711 - 704

octet 112 113 114 115 116 117 118 119
bit offset 703 - 696 695 - 688 687 - 680 679 - 672 671 - 664 663 - 656 655 - 648 647 - 640

octet 120 121 122 123 124 125 126 127
bit offset 639 - 632 631 - 624 623 - 616 615 - 608 607 - 600 599 - 592 591 - 584 583 - 576

octet 128 129 130 131 132 133 134 135
bit offset 575 - 568 567 - 560 559 - 552 551 - 544 543 - 536 535 - 528 527 - 520 519 - 512

octet 136 137 138 139 140 141 142 143
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 144 145 146 147 148 149 150 151
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 152 153 154 155 156 157 158 159
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 160 161 162 163 164 165 166 167
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 168 169 170 171 172 173 174 175
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 176 177 178 179 180 181 182 183
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 184 185 186 187 188 189 190 191
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 192 193 194 195 196 197 198 199
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Messwertaufzeichnung Ringpuffer 8" index=2029 id=V_HistogrammPuffer8

description: Dieses Element enthält die Elemente 700...799 des Ringpuffers der Messwertaufzeichnung.
data type: 200-octet OctetString
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 1599 - 1592 1591 - 1584 1583 - 1576 1575 - 1568 1567 - 1560 1559 - 1552 1551 - 1544 1543 - 1536

octet 8 9 10 11 12 13 14 15
bit offset 1535 - 1528 1527 - 1520 1519 - 1512 1511 - 1504 1503 - 1496 1495 - 1488 1487 - 1480 1479 - 1472

octet 16 17 18 19 20 21 22 23
bit offset 1471 - 1464 1463 - 1456 1455 - 1448 1447 - 1440 1439 - 1432 1431 - 1424 1423 - 1416 1415 - 1408

octet 24 25 26 27 28 29 30 31
bit offset 1407 - 1400 1399 - 1392 1391 - 1384 1383 - 1376 1375 - 1368 1367 - 1360 1359 - 1352 1351 - 1344

octet 32 33 34 35 36 37 38 39
bit offset 1343 - 1336 1335 - 1328 1327 - 1320 1319 - 1312 1311 - 1304 1303 - 1296 1295 - 1288 1287 - 1280

octet 40 41 42 43 44 45 46 47
bit offset 1279 - 1272 1271 - 1264 1263 - 1256 1255 - 1248 1247 - 1240 1239 - 1232 1231 - 1224 1223 - 1216

octet 48 49 50 51 52 53 54 55
bit offset 1215 - 1208 1207 - 1200 1199 - 1192 1191 - 1184 1183 - 1176 1175 - 1168 1167 - 1160 1159 - 1152

octet 56 57 58 59 60 61 62 63
bit offset 1151 - 1144 1143 - 1136 1135 - 1128 1127 - 1120 1119 - 1112 1111 - 1104 1103 - 1096 1095 - 1088

octet 64 65 66 67 68 69 70 71
bit offset 1087 - 1080 1079 - 1072 1071 - 1064 1063 - 1056 1055 - 1048 1047 - 1040 1039 - 1032 1031 - 1024

octet 72 73 74 75 76 77 78 79
bit offset 1023 - 1016 1015 - 1008 1007 - 1000 999 - 992 991 - 984 983 - 976 975 - 968 967 - 960

octet 80 81 82 83 84 85 86 87
bit offset 959 - 952 951 - 944 943 - 936 935 - 928 927 - 920 919 - 912 911 - 904 903 - 896

octet 88 89 90 91 92 93 94 95
bit offset 895 - 888 887 - 880 879 - 872 871 - 864 863 - 856 855 - 848 847 - 840 839 - 832

octet 96 97 98 99 100 101 102 103
bit offset 831 - 824 823 - 816 815 - 808 807 - 800 799 - 792 791 - 784 783 - 776 775 - 768

octet 104 105 106 107 108 109 110 111
bit offset 767 - 760 759 - 752 751 - 744 743 - 736 735 - 728 727 - 720 719 - 712 711 - 704

octet 112 113 114 115 116 117 118 119
bit offset 703 - 696 695 - 688 687 - 680 679 - 672 671 - 664 663 - 656 655 - 648 647 - 640

octet 120 121 122 123 124 125 126 127
bit offset 639 - 632 631 - 624 623 - 616 615 - 608 607 - 600 599 - 592 591 - 584 583 - 576

octet 128 129 130 131 132 133 134 135
bit offset 575 - 568 567 - 560 559 - 552 551 - 544 543 - 536 535 - 528 527 - 520 519 - 512

octet 136 137 138 139 140 141 142 143
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 144 145 146 147 148 149 150 151
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 152 153 154 155 156 157 158 159
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 160 161 162 163 164 165 166 167
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 168 169 170 171 172 173 174 175
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 176 177 178 179 180 181 182 183
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 184 185 186 187 188 189 190 191
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 192 193 194 195 196 197 198 199
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Messwertaufzeichnung Ringpuffer 9" index=2030 id=V_HistogrammPuffer9

description: Dieses Element enthält die Elemente 80...899 des Ringpuffers der Messwertaufzeichnung.
data type: 200-octet OctetString
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 1599 - 1592 1591 - 1584 1583 - 1576 1575 - 1568 1567 - 1560 1559 - 1552 1551 - 1544 1543 - 1536

octet 8 9 10 11 12 13 14 15
bit offset 1535 - 1528 1527 - 1520 1519 - 1512 1511 - 1504 1503 - 1496 1495 - 1488 1487 - 1480 1479 - 1472

octet 16 17 18 19 20 21 22 23
bit offset 1471 - 1464 1463 - 1456 1455 - 1448 1447 - 1440 1439 - 1432 1431 - 1424 1423 - 1416 1415 - 1408

octet 24 25 26 27 28 29 30 31
bit offset 1407 - 1400 1399 - 1392 1391 - 1384 1383 - 1376 1375 - 1368 1367 - 1360 1359 - 1352 1351 - 1344

octet 32 33 34 35 36 37 38 39
bit offset 1343 - 1336 1335 - 1328 1327 - 1320 1319 - 1312 1311 - 1304 1303 - 1296 1295 - 1288 1287 - 1280

octet 40 41 42 43 44 45 46 47
bit offset 1279 - 1272 1271 - 1264 1263 - 1256 1255 - 1248 1247 - 1240 1239 - 1232 1231 - 1224 1223 - 1216

octet 48 49 50 51 52 53 54 55
bit offset 1215 - 1208 1207 - 1200 1199 - 1192 1191 - 1184 1183 - 1176 1175 - 1168 1167 - 1160 1159 - 1152

octet 56 57 58 59 60 61 62 63
bit offset 1151 - 1144 1143 - 1136 1135 - 1128 1127 - 1120 1119 - 1112 1111 - 1104 1103 - 1096 1095 - 1088

octet 64 65 66 67 68 69 70 71
bit offset 1087 - 1080 1079 - 1072 1071 - 1064 1063 - 1056 1055 - 1048 1047 - 1040 1039 - 1032 1031 - 1024

octet 72 73 74 75 76 77 78 79
bit offset 1023 - 1016 1015 - 1008 1007 - 1000 999 - 992 991 - 984 983 - 976 975 - 968 967 - 960

octet 80 81 82 83 84 85 86 87
bit offset 959 - 952 951 - 944 943 - 936 935 - 928 927 - 920 919 - 912 911 - 904 903 - 896

octet 88 89 90 91 92 93 94 95
bit offset 895 - 888 887 - 880 879 - 872 871 - 864 863 - 856 855 - 848 847 - 840 839 - 832

octet 96 97 98 99 100 101 102 103
bit offset 831 - 824 823 - 816 815 - 808 807 - 800 799 - 792 791 - 784 783 - 776 775 - 768

octet 104 105 106 107 108 109 110 111
bit offset 767 - 760 759 - 752 751 - 744 743 - 736 735 - 728 727 - 720 719 - 712 711 - 704

octet 112 113 114 115 116 117 118 119
bit offset 703 - 696 695 - 688 687 - 680 679 - 672 671 - 664 663 - 656 655 - 648 647 - 640

octet 120 121 122 123 124 125 126 127
bit offset 639 - 632 631 - 624 623 - 616 615 - 608 607 - 600 599 - 592 591 - 584 583 - 576

octet 128 129 130 131 132 133 134 135
bit offset 575 - 568 567 - 560 559 - 552 551 - 544 543 - 536 535 - 528 527 - 520 519 - 512

octet 136 137 138 139 140 141 142 143
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 144 145 146 147 148 149 150 151
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 152 153 154 155 156 157 158 159
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 160 161 162 163 164 165 166 167
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 168 169 170 171 172 173 174 175
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 176 177 178 179 180 181 182 183
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 184 185 186 187 188 189 190 191
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 192 193 194 195 196 197 198 199
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Messwertaufzeichnung Ringpuffer 10" index=2031 id=V_HistogrammPuffer10

description: Dieses Element enthält die Elemente 900...999 des Ringpuffers der Messwertaufzeichnung.
data type: 200-octet OctetString
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 1599 - 1592 1591 - 1584 1583 - 1576 1575 - 1568 1567 - 1560 1559 - 1552 1551 - 1544 1543 - 1536

octet 8 9 10 11 12 13 14 15
bit offset 1535 - 1528 1527 - 1520 1519 - 1512 1511 - 1504 1503 - 1496 1495 - 1488 1487 - 1480 1479 - 1472

octet 16 17 18 19 20 21 22 23
bit offset 1471 - 1464 1463 - 1456 1455 - 1448 1447 - 1440 1439 - 1432 1431 - 1424 1423 - 1416 1415 - 1408

octet 24 25 26 27 28 29 30 31
bit offset 1407 - 1400 1399 - 1392 1391 - 1384 1383 - 1376 1375 - 1368 1367 - 1360 1359 - 1352 1351 - 1344

octet 32 33 34 35 36 37 38 39
bit offset 1343 - 1336 1335 - 1328 1327 - 1320 1319 - 1312 1311 - 1304 1303 - 1296 1295 - 1288 1287 - 1280

octet 40 41 42 43 44 45 46 47
bit offset 1279 - 1272 1271 - 1264 1263 - 1256 1255 - 1248 1247 - 1240 1239 - 1232 1231 - 1224 1223 - 1216

octet 48 49 50 51 52 53 54 55
bit offset 1215 - 1208 1207 - 1200 1199 - 1192 1191 - 1184 1183 - 1176 1175 - 1168 1167 - 1160 1159 - 1152

octet 56 57 58 59 60 61 62 63
bit offset 1151 - 1144 1143 - 1136 1135 - 1128 1127 - 1120 1119 - 1112 1111 - 1104 1103 - 1096 1095 - 1088

octet 64 65 66 67 68 69 70 71
bit offset 1087 - 1080 1079 - 1072 1071 - 1064 1063 - 1056 1055 - 1048 1047 - 1040 1039 - 1032 1031 - 1024

octet 72 73 74 75 76 77 78 79
bit offset 1023 - 1016 1015 - 1008 1007 - 1000 999 - 992 991 - 984 983 - 976 975 - 968 967 - 960

octet 80 81 82 83 84 85 86 87
bit offset 959 - 952 951 - 944 943 - 936 935 - 928 927 - 920 919 - 912 911 - 904 903 - 896

octet 88 89 90 91 92 93 94 95
bit offset 895 - 888 887 - 880 879 - 872 871 - 864 863 - 856 855 - 848 847 - 840 839 - 832

octet 96 97 98 99 100 101 102 103
bit offset 831 - 824 823 - 816 815 - 808 807 - 800 799 - 792 791 - 784 783 - 776 775 - 768

octet 104 105 106 107 108 109 110 111
bit offset 767 - 760 759 - 752 751 - 744 743 - 736 735 - 728 727 - 720 719 - 712 711 - 704

octet 112 113 114 115 116 117 118 119
bit offset 703 - 696 695 - 688 687 - 680 679 - 672 671 - 664 663 - 656 655 - 648 647 - 640

octet 120 121 122 123 124 125 126 127
bit offset 639 - 632 631 - 624 623 - 616 615 - 608 607 - 600 599 - 592 591 - 584 583 - 576

octet 128 129 130 131 132 133 134 135
bit offset 575 - 568 567 - 560 559 - 552 551 - 544 543 - 536 535 - 528 527 - 520 519 - 512

octet 136 137 138 139 140 141 142 143
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 144 145 146 147 148 149 150 151
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 152 153 154 155 156 157 158 159
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 160 161 162 163 164 165 166 167
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 168 169 170 171 172 173 174 175
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 176 177 178 179 180 181 182 183
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 184 185 186 187 188 189 190 191
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 192 193 194 195 196 197 198 199
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Messdatenkanalbeschreibung" index=16512 id=V_SSP_MDC_Descriptor

description: Beschreibt die Charakteristik des Messdatenkanals.
data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer Unterer Grenzwert Unterer Grenzwert des Messbereiches.
2 24 32-bit Integer Oberer Grenzwert Oberer Grenzwert des Messbereiches.
3 8 16-bit UInteger 1001 = °C, 1005 = °, 1010 = m, 1034 = m³, 1061 = m/s, 1076 = m/s², 1077 = Hz, 1085 = rpm, 1088 = kg, 1120 = N, 1126 = Nm, 1130 = Pa, 1164 = cSt, 1186 = W, 1209 = A, 1240 = V, 1299 = S/m, 1322 = kg/s, 1342 = %, 1349 = m³/h, 1383 = dB, 1422 = pH, 1423 = ppm, 1675 = B/s, 1684 = bit/s, 1689 = dBm, 1691 = °/s, 1692 = °/s², 1694 = bit, 1997 = none 1697 Einheitencode Zeigt den eindeutigen Code für die physische Einheit an.
4 0 8-bit Integer Skala Zeigt den Multiplikator für den Messwert - 10exp(Skala).

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Events

CodeTypeNameDescription
16384 (0x4000)ErrorTemperaturfehlerÜberlast
16912 (0x4210)WarningZulässige Gerätetemperatur überschrittenWärmequellen beseitigen
16928 (0x4220)WarningZulässige Gerätetemperatur unterschrittenGerät isolieren
20736 (0x5100)ErrorAllgemeiner Fehler der VersorgungsspannungVerfügbarkeit prüfen
30480 (0x7710)ErrorKurzschlussInstallation prüfen
36000 (0x8ca0)NotificationManueller Teach-in fehlgeschlagenDer manuelle Teach-in Prozess war fehlerhaft.
36001 (0x8ca1)NotificationManueller Teach-in erfolgreichDer manuelle Teach-in Prozess war erfolgreich.
36003 (0x8ca3)WarningManueller Teach-in wird durchgeführtDer Sensor kann nicht konfiguriert werden, weil ein Teach-in Vorgang per Taste oder Pin 5 aktiv ist.
36004 (0x8ca4)WarningDatensatz zur Materialeinstellung stimmt nicht mit dem Sensor übereinDer Materialeinstellungsdatensatz stimmt nicht mit dem Sensor überein. Bitte führen Sie ein Teach-in durch.
36010 (0x8caa)NotificationHistorien Event ausgelöstDas Historien Event wurde ausgelöst. Der Ringpuffer ist bereit.

Process Data Formatting

Formatting for Process Data id=PI_SSP_PDI32_MDC32
Subindex 1: * 1 + 0 Dec.0
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5:

Formatting for Process Data id=PO_SSP_PDO8_CSC
Subindex 1:
Subindex 4:

Operator Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag, ro
V_CP_FunctionTag, ro
V_CP_LocationTag, ro
V_CP_ProductURI

Parameters Menu
Messung
V_Messkonfig.Montageabstand * 1 + 0 mm, ro Dec.0
V_Messkonfig.Sendeleistung, ro
V_Delay.Ausschaltverzögerung Doppelbogen ms, ro
V_Delay.Einschaltverzögerung Fehlbogen ms, ro
V_Delay.Einschaltverzögerung Doppelbogen ms, ro
Schnittstellen
V_SchnittstellenAusgang.Ausgangsfunktion D1, ro
V_SchnittstellenAusgang.Ausgangsfunktion D2, ro
V_SchnittstellenAusgang.Ausgangslogik D1, ro
V_SchnittstellenAusgang.Ausgangslogik D2, ro
V_SchnittstellenEingang.Eingangscharakteristik, ro
Trigger und Synchronisation
V_SyncMux.Trigger Kanal, ro
V_SyncMux.Trigger Modus, ro
Bedienoberfläche
V_BedienungEingabe.Modus, ro
V_BedienungAusgabe.Modus, ro
Rezeptspeicher-Konfiguration
V_Rezeptspeicher_Konfig.Teach-in Rezeptspeicher, ro
Rezeptspeicher 1
V_RezeptspeicherHV_Rezept1.Sendelänge, ro
V_RezeptspeicherHV_Rezept1.Verstärkung, ro
V_RezeptspeicherHV_Rezept1.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept1.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept1.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept1.CRC, ro
Rezeptspeicher 2
V_RezeptspeicherHV_Rezept2.Sendelänge, ro
V_RezeptspeicherHV_Rezept2.Verstärkung, ro
V_RezeptspeicherHV_Rezept2.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept2.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept2.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept2.CRC, ro
Rezeptspeicher 3
V_RezeptspeicherHV_Rezept3.Sendelänge, ro
V_RezeptspeicherHV_Rezept3.Verstärkung, ro
V_RezeptspeicherHV_Rezept3.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept3.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept3.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept3.CRC, ro
Rezeptspeicher 4
V_RezeptspeicherHV_Rezept4.Sendelänge, ro
V_RezeptspeicherHV_Rezept4.Verstärkung, ro
V_RezeptspeicherHV_Rezept4.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept4.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept4.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept4.CRC, ro
Rezeptspeicher LP 1
V_RezeptspeicherLV_Rezept1.Sendelänge, ro
V_RezeptspeicherLV_Rezept1.Verstärkung, ro
V_RezeptspeicherLV_Rezept1.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept1.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept1.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept1.CRC, ro
Rezeptspeicher LP 2
V_RezeptspeicherLV_Rezept2.Sendelänge, ro
V_RezeptspeicherLV_Rezept2.Verstärkung, ro
V_RezeptspeicherLV_Rezept2.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept2.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept2.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept2.CRC, ro
Rezeptspeicher LP 3
V_RezeptspeicherLV_Rezept3.Sendelänge, ro
V_RezeptspeicherLV_Rezept3.Verstärkung, ro
V_RezeptspeicherLV_Rezept3.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept3.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept3.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept3.CRC, ro
Rezeptspeicher LP 4
V_RezeptspeicherLV_Rezept4.Sendelänge, ro
V_RezeptspeicherLV_Rezept4.Verstärkung, ro
V_RezeptspeicherLV_Rezept4.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept4.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept4.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept4.CRC, ro

Observation Menu
Fehlerhistorie
V_DiagLaufzeit.Fehleranzahl, ro
detaillierte Fehlerhistorie
V_DiagFehlerHistorie.Zeitpunkt[0] min, ro
V_DiagFehlerHistorie.Beschreibung[0], ro
V_DiagFehlerHistorie.Zeitpunkt[1] min, ro
V_DiagFehlerHistorie.Beschreibung[1], ro
V_DiagFehlerHistorie.Zeitpunkt[2] min, ro
V_DiagFehlerHistorie.Beschreibung[2], ro
V_DiagFehlerHistorie.Zeitpunkt[3] min, ro
V_DiagFehlerHistorie.Beschreibung[3], ro
V_DiagFehlerHistorie.Zeitpunkt[4] min, ro
V_DiagFehlerHistorie.Beschreibung[4], ro
V_DiagFehlerHistorie.Zeitpunkt[5] min, ro
V_DiagFehlerHistorie.Beschreibung[5], ro
V_DiagFehlerHistorie.Zeitpunkt[6] min, ro
V_DiagFehlerHistorie.Beschreibung[6], ro
V_DiagFehlerHistorie.Zeitpunkt[7] min, ro
V_DiagFehlerHistorie.Beschreibung[7], ro
V_DiagFehlerHistorie.Zeitpunkt[8] min, ro
V_DiagFehlerHistorie.Beschreibung[8], ro
V_DiagFehlerHistorie.Zeitpunkt[9] min, ro
V_DiagFehlerHistorie.Beschreibung[9], ro
V_DiagFehlerHistorie.Zeitpunkt[10] min, ro
V_DiagFehlerHistorie.Beschreibung[10], ro
V_DiagFehlerHistorie.Zeitpunkt[11] min, ro
V_DiagFehlerHistorie.Beschreibung[11], ro
V_DiagFehlerHistorie.Zeitpunkt[12] min, ro
V_DiagFehlerHistorie.Beschreibung[12], ro
V_DiagFehlerHistorie.Zeitpunkt[13] min, ro
V_DiagFehlerHistorie.Beschreibung[13], ro
V_DiagFehlerHistorie.Zeitpunkt[14] min, ro
V_DiagFehlerHistorie.Beschreibung[14], ro
V_DiagFehlerHistorie.Zeitpunkt[15] min, ro
V_DiagFehlerHistorie.Beschreibung[15], ro
V_DiagFehlerHistorie.Zeitpunkt[16] min, ro
V_DiagFehlerHistorie.Beschreibung[16], ro
V_DiagFehlerHistorie.Zeitpunkt[17] min, ro
V_DiagFehlerHistorie.Beschreibung[17], ro
V_DiagFehlerHistorie.Zeitpunkt[18] min, ro
V_DiagFehlerHistorie.Beschreibung[18], ro
V_DiagFehlerHistorie.Zeitpunkt[19] min, ro
V_DiagFehlerHistorie.Beschreibung[19], ro
V_DiagFehlerHistorie.Zeitpunkt[20] min, ro
V_DiagFehlerHistorie.Beschreibung[20], ro
V_DiagFehlerHistorie.Zeitpunkt[21] min, ro
V_DiagFehlerHistorie.Beschreibung[21], ro
V_DiagFehlerHistorie.Zeitpunkt[22] min, ro
V_DiagFehlerHistorie.Beschreibung[22], ro
V_DiagFehlerHistorie.Zeitpunkt[23] min, ro
V_DiagFehlerHistorie.Beschreibung[23], ro
V_DiagFehlerHistorie.Zeitpunkt[24] min, ro
V_DiagFehlerHistorie.Beschreibung[24], ro
V_DiagFehlerHistorie.Zeitpunkt[25] min, ro
V_DiagFehlerHistorie.Beschreibung[25], ro
V_DiagFehlerHistorie.Zeitpunkt[26] min, ro
V_DiagFehlerHistorie.Beschreibung[26], ro
V_DiagFehlerHistorie.Zeitpunkt[27] min, ro
V_DiagFehlerHistorie.Beschreibung[27], ro
V_DiagFehlerHistorie.Zeitpunkt[28] min, ro
V_DiagFehlerHistorie.Beschreibung[28], ro
V_DiagFehlerHistorie.Zeitpunkt[29] min, ro
V_DiagFehlerHistorie.Beschreibung[29], ro
V_DiagFehlerHistorie.Zeitpunkt[30] min, ro
V_DiagFehlerHistorie.Beschreibung[30], ro
V_DiagFehlerHistorie.Zeitpunkt[31] min, ro
V_DiagFehlerHistorie.Beschreibung[31], ro
Messung
V_Messkonfig.Montageabstand * 1 + 0 mm, ro Dec.0
V_Messkonfig.Sendeleistung, ro
V_Delay.Ausschaltverzögerung Doppelbogen ms, ro
V_Delay.Einschaltverzögerung Fehlbogen ms, ro
V_Delay.Einschaltverzögerung Doppelbogen ms, ro
Schnittstellen
V_SchnittstellenAusgang.Ausgangsfunktion D1, ro
V_SchnittstellenAusgang.Ausgangsfunktion D2, ro
V_SchnittstellenAusgang.Ausgangslogik D1, ro
V_SchnittstellenAusgang.Ausgangslogik D2, ro
V_SchnittstellenEingang.Eingangscharakteristik, ro
Trigger und Synchronisation
V_SyncMux.Trigger Kanal, ro
V_SyncMux.Trigger Modus, ro
Bedienoberfläche
V_BedienungEingabe.Modus, ro
V_BedienungAusgabe.Modus, ro
Diagnose
V_DiagMessung.Material Inhomogenität * 0.1 + 0 %, ro Dec.1
V_DiagTeachin.Status, ro
V_DiagZeit.SIO-Modus * 0.01 + 0 ms, ro Dec.2
V_DiagZeit.IO-Link * 0.01 + 0 ms, ro Dec.2
V_VENDOR_Temperature.Aktuelle Temperatur * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Max. Sensortemperatur allzeit * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Min. Sensortemperatur allzeit * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Max. Sensortemperatur seit letztem Reset * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Min. Sensortemperatur seit letztem Reset * 0.1 + 0 °C, ro Dec.1
V_DiagLaufzeit.Betriebszeitzähler * 0.01666667 + 0 h, ro Dec.2
V_DiagLaufzeit.Betriebszeitzähler seit Reset * 0.01666667 + 0 h, ro Dec.2
V_DiagLaufzeit.Bootzyklen, ro
V_DiagLaufzeit.EEProm Schreibzyklen, ro
V_DiagCounter.Einzelbogen, ro
V_DiagCounter.Doppelbogen, ro
V_DiagCounter.Übersteuerung, ro
V_DiagCounter.Fehlbogen, ro
Rezeptspeicher-Konfiguration
V_Rezeptspeicher_Konfig.Teach-in Rezeptspeicher, ro
Rezeptspeicher 1
V_RezeptspeicherHV_Rezept1.Sendelänge, ro
V_RezeptspeicherHV_Rezept1.Verstärkung, ro
V_RezeptspeicherHV_Rezept1.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept1.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept1.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept1.CRC, ro
Rezeptspeicher 2
V_RezeptspeicherHV_Rezept2.Sendelänge, ro
V_RezeptspeicherHV_Rezept2.Verstärkung, ro
V_RezeptspeicherHV_Rezept2.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept2.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept2.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept2.CRC, ro
Rezeptspeicher 3
V_RezeptspeicherHV_Rezept3.Sendelänge, ro
V_RezeptspeicherHV_Rezept3.Verstärkung, ro
V_RezeptspeicherHV_Rezept3.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept3.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept3.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept3.CRC, ro
Rezeptspeicher 4
V_RezeptspeicherHV_Rezept4.Sendelänge, ro
V_RezeptspeicherHV_Rezept4.Verstärkung, ro
V_RezeptspeicherHV_Rezept4.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept4.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept4.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept4.CRC, ro
Rezeptspeicher LP 1
V_RezeptspeicherLV_Rezept1.Sendelänge, ro
V_RezeptspeicherLV_Rezept1.Verstärkung, ro
V_RezeptspeicherLV_Rezept1.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept1.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept1.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept1.CRC, ro
Rezeptspeicher LP 2
V_RezeptspeicherLV_Rezept2.Sendelänge, ro
V_RezeptspeicherLV_Rezept2.Verstärkung, ro
V_RezeptspeicherLV_Rezept2.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept2.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept2.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept2.CRC, ro
Rezeptspeicher LP 3
V_RezeptspeicherLV_Rezept3.Sendelänge, ro
V_RezeptspeicherLV_Rezept3.Verstärkung, ro
V_RezeptspeicherLV_Rezept3.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept3.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept3.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept3.CRC, ro
Rezeptspeicher LP 4
V_RezeptspeicherLV_Rezept4.Sendelänge, ro
V_RezeptspeicherLV_Rezept4.Verstärkung, ro
V_RezeptspeicherLV_Rezept4.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept4.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept4.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept4.CRC, ro

Diagnosis Menu
Gerätestatusinformationen
V_DeviceStatus
V_DetailedDeviceStatus
V_ErrorCount
Servicefunktionen
V_SystemCommand, Button:=126
Description=Die visuellen Anzeigen des Geräts werden auf das Lokalisierungsanzeigemuster umgeschaltet, wodurch das Erkennen eines Geräts in einer Anwendung erleichtert wird.
V_SystemCommand, Button:=127
Description=Das Lokalisierungsanzeigemuster wird gestoppt. Die optischen Anzeigen des Geräts zeigen wieder die gerätespezifischen Betriebszustände an.
Messdatenkanalbeschreibung
V_SSP_MDC_Descriptor
Diagnose
V_DiagMessung.Material Inhomogenität * 0.1 + 0 %, ro Dec.1
V_DiagTeachin.Status, ro
V_DiagZeit.SIO-Modus * 0.01 + 0 ms, ro Dec.2
V_DiagZeit.IO-Link * 0.01 + 0 ms, ro Dec.2
V_VENDOR_Temperature.Aktuelle Temperatur * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Max. Sensortemperatur allzeit * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Min. Sensortemperatur allzeit * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Max. Sensortemperatur seit letztem Reset * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Min. Sensortemperatur seit letztem Reset * 0.1 + 0 °C, ro Dec.1
V_DiagLaufzeit.Betriebszeitzähler * 0.01666667 + 0 h, ro Dec.2
V_DiagLaufzeit.Betriebszeitzähler seit Reset * 0.01666667 + 0 h, ro Dec.2
V_DiagLaufzeit.Bootzyklen, ro
V_DiagLaufzeit.EEProm Schreibzyklen, ro
V_DiagCounter.Einzelbogen, ro
V_DiagCounter.Doppelbogen, ro
V_DiagCounter.Übersteuerung, ro
V_DiagCounter.Fehlbogen, ro
Diagnose
V_DiagZusammenfassung.Messwert, ro
V_DiagZusammenfassung.Ausgang D1, ro
V_DiagZusammenfassung.Ausgang D2, ro
V_DiagZusammenfassung.Eingang C1, ro
V_DiagZusammenfassung.Eingang C2, ro
V_DiagZusammenfassung.Eingang C3, ro
Messwertaufzeichnung
V_HistogrammConfig.Event senden, ro
V_HistogrammConfig.Trigger, ro
V_HistogrammConfig.Modus, ro
V_HistogrammConfig.Post-Trigger, ro
V_HistogrammPufferHeader.Zeiger Ringpuffer, ro
V_HistogrammPuffer1, ro
V_HistogrammPuffer2, ro
V_HistogrammPuffer3, ro
V_HistogrammPuffer4, ro
V_HistogrammPuffer5, ro
V_HistogrammPuffer6, ro
V_HistogrammPuffer7, ro
V_HistogrammPuffer8, ro
V_HistogrammPuffer9, ro
V_HistogrammPuffer10, ro

Maintenance Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag
V_CP_ProductURI

Parameters Menu
Servicefunktionen
V_SystemCommand, Button:=129
Description=Die Parameter der technologiespezifischen Anwendung werden auf Standardwerte gesetzt. Identifikationsparameter bleiben unverändert. Ein Upload in den Datenspeicher des Masters wird ausgeführt, sofern in der Portkonfiguration des Masters aktiviert.
V_SystemCommand, Button:=131
Description=Die Parameter des Geräts werden auf die Werkseinstellungen gesetzt und die Kommunikation wird bis zum nächsten Aus- und Einschalten gesperrt. Hinweis: Trennen Sie das Gerät direkt vom Master-Port!
Allgemeine Einstellungen
V_SystemCommand, Button:=128
Description=Ein Warmstart wird ausgelöst und das Gerät in einen Ausgangszustand versetzt. Die Kommunikation wird vom Gerät unterbrochen und dann vom Master neu gestartet.
V_SystemCommand, Button:=129
Description=Die Parameter der technologiespezifischen Anwendung werden auf Standardwerte gesetzt. Identifikationsparameter bleiben unverändert. Ein Upload in den Datenspeicher des Masters wird ausgeführt, sofern in der Portkonfiguration des Masters aktiviert.
V_SystemCommand, Button:=130
Description=Die Parameter des Geräts werden auf die Werkseinstellungen zurückgesetzt. Hinweis: Ein Download des Datenspeichers wird möglicherweise beim nächsten Aus- und Einschalten ausgeführt und die Werkseinstellungen überschrieben!
V_SystemCommand, Button:=131
Description=Die Parameter des Geräts werden auf die Werkseinstellungen gesetzt und die Kommunikation wird bis zum nächsten Aus- und Einschalten gesperrt. Hinweis: Trennen Sie das Gerät direkt vom Master-Port!
Device access locks
V_DeviceAccessLocks.Lokale Parametrierung, rw
V_DeviceAccessLocks.Lokale Benutzerschnittstelle, rw
Teach-in Kanal
V_SystemCommand, Button:=161
V_SystemCommand, Button:=162
V_SystemCommand, Button:=169
V_SSP_TI_TeachResult
V_TeachinKonfig.Typ, rw
V_TeachinKonfig.Offset * 1 + 0 %, rw Dec.1
Messung
V_Messkonfig.Montageabstand * 1 + 0 mm, rw Dec.0
V_Messkonfig.Sendeleistung, rw
V_SystemCommand, Button:=173
V_Delay.Ausschaltverzögerung Doppelbogen ms, rw
V_Delay.Einschaltverzögerung Fehlbogen ms, rw
V_Delay.Einschaltverzögerung Doppelbogen ms, rw
Schnittstellen
V_SchnittstellenAusgang.Ausgangsfunktion D1, rw
V_SchnittstellenAusgang.Ausgangsfunktion D2, rw
V_SchnittstellenAusgang.Ausgangslogik D1, rw
V_SchnittstellenAusgang.Ausgangslogik D2, rw
V_SchnittstellenEingang.Eingangscharakteristik, rw
Trigger und Synchronisation
V_SyncMux.Trigger Kanal, rw
V_SyncMux.Trigger Modus, rw
Bedienoberfläche
V_BedienungEingabe.Modus, rw
V_BedienungAusgabe.Modus, rw
Rezeptspeicher-Konfiguration
V_Rezeptspeicher_Konfig.Teach-in Rezeptspeicher, rw
Rezeptspeicher 1
V_RezeptspeicherHV_Rezept1.Sendelänge, rw
V_RezeptspeicherHV_Rezept1.Verstärkung, rw
V_RezeptspeicherHV_Rezept1.Auswertungstyp, rw
V_RezeptspeicherHV_Rezept1.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherHV_Rezept1.Schwellwert Doppelbogen, rw
V_RezeptspeicherHV_Rezept1.CRC, rw
Rezeptspeicher 2
V_RezeptspeicherHV_Rezept2.Sendelänge, rw
V_RezeptspeicherHV_Rezept2.Verstärkung, rw
V_RezeptspeicherHV_Rezept2.Auswertungstyp, rw
V_RezeptspeicherHV_Rezept2.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherHV_Rezept2.Schwellwert Doppelbogen, rw
V_RezeptspeicherHV_Rezept2.CRC, rw
Rezeptspeicher 3
V_RezeptspeicherHV_Rezept3.Sendelänge, rw
V_RezeptspeicherHV_Rezept3.Verstärkung, rw
V_RezeptspeicherHV_Rezept3.Auswertungstyp, rw
V_RezeptspeicherHV_Rezept3.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherHV_Rezept3.Schwellwert Doppelbogen, rw
V_RezeptspeicherHV_Rezept3.CRC, rw
Rezeptspeicher 4
V_RezeptspeicherHV_Rezept4.Sendelänge, rw
V_RezeptspeicherHV_Rezept4.Verstärkung, rw
V_RezeptspeicherHV_Rezept4.Auswertungstyp, rw
V_RezeptspeicherHV_Rezept4.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherHV_Rezept4.Schwellwert Doppelbogen, rw
V_RezeptspeicherHV_Rezept4.CRC, rw
Rezeptspeicher LP 1
V_RezeptspeicherLV_Rezept1.Sendelänge, rw
V_RezeptspeicherLV_Rezept1.Verstärkung, rw
V_RezeptspeicherLV_Rezept1.Auswertungstyp, rw
V_RezeptspeicherLV_Rezept1.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherLV_Rezept1.Schwellwert Doppelbogen, rw
V_RezeptspeicherLV_Rezept1.CRC, rw
Rezeptspeicher LP 2
V_RezeptspeicherLV_Rezept2.Sendelänge, rw
V_RezeptspeicherLV_Rezept2.Verstärkung, rw
V_RezeptspeicherLV_Rezept2.Auswertungstyp, rw
V_RezeptspeicherLV_Rezept2.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherLV_Rezept2.Schwellwert Doppelbogen, rw
V_RezeptspeicherLV_Rezept2.CRC, rw
Rezeptspeicher LP 3
V_RezeptspeicherLV_Rezept3.Sendelänge, rw
V_RezeptspeicherLV_Rezept3.Verstärkung, rw
V_RezeptspeicherLV_Rezept3.Auswertungstyp, rw
V_RezeptspeicherLV_Rezept3.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherLV_Rezept3.Schwellwert Doppelbogen, rw
V_RezeptspeicherLV_Rezept3.CRC, rw
Rezeptspeicher LP 4
V_RezeptspeicherLV_Rezept4.Sendelänge, rw
V_RezeptspeicherLV_Rezept4.Verstärkung, rw
V_RezeptspeicherLV_Rezept4.Auswertungstyp, rw
V_RezeptspeicherLV_Rezept4.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherLV_Rezept4.Schwellwert Doppelbogen, rw
V_RezeptspeicherLV_Rezept4.CRC, rw

Observation Menu
Fehlerhistorie
V_DiagLaufzeit.Fehleranzahl, ro
detaillierte Fehlerhistorie
V_DiagFehlerHistorie.Zeitpunkt[0] min, ro
V_DiagFehlerHistorie.Beschreibung[0], ro
V_DiagFehlerHistorie.Zeitpunkt[1] min, ro
V_DiagFehlerHistorie.Beschreibung[1], ro
V_DiagFehlerHistorie.Zeitpunkt[2] min, ro
V_DiagFehlerHistorie.Beschreibung[2], ro
V_DiagFehlerHistorie.Zeitpunkt[3] min, ro
V_DiagFehlerHistorie.Beschreibung[3], ro
V_DiagFehlerHistorie.Zeitpunkt[4] min, ro
V_DiagFehlerHistorie.Beschreibung[4], ro
V_DiagFehlerHistorie.Zeitpunkt[5] min, ro
V_DiagFehlerHistorie.Beschreibung[5], ro
V_DiagFehlerHistorie.Zeitpunkt[6] min, ro
V_DiagFehlerHistorie.Beschreibung[6], ro
V_DiagFehlerHistorie.Zeitpunkt[7] min, ro
V_DiagFehlerHistorie.Beschreibung[7], ro
V_DiagFehlerHistorie.Zeitpunkt[8] min, ro
V_DiagFehlerHistorie.Beschreibung[8], ro
V_DiagFehlerHistorie.Zeitpunkt[9] min, ro
V_DiagFehlerHistorie.Beschreibung[9], ro
V_DiagFehlerHistorie.Zeitpunkt[10] min, ro
V_DiagFehlerHistorie.Beschreibung[10], ro
V_DiagFehlerHistorie.Zeitpunkt[11] min, ro
V_DiagFehlerHistorie.Beschreibung[11], ro
V_DiagFehlerHistorie.Zeitpunkt[12] min, ro
V_DiagFehlerHistorie.Beschreibung[12], ro
V_DiagFehlerHistorie.Zeitpunkt[13] min, ro
V_DiagFehlerHistorie.Beschreibung[13], ro
V_DiagFehlerHistorie.Zeitpunkt[14] min, ro
V_DiagFehlerHistorie.Beschreibung[14], ro
V_DiagFehlerHistorie.Zeitpunkt[15] min, ro
V_DiagFehlerHistorie.Beschreibung[15], ro
V_DiagFehlerHistorie.Zeitpunkt[16] min, ro
V_DiagFehlerHistorie.Beschreibung[16], ro
V_DiagFehlerHistorie.Zeitpunkt[17] min, ro
V_DiagFehlerHistorie.Beschreibung[17], ro
V_DiagFehlerHistorie.Zeitpunkt[18] min, ro
V_DiagFehlerHistorie.Beschreibung[18], ro
V_DiagFehlerHistorie.Zeitpunkt[19] min, ro
V_DiagFehlerHistorie.Beschreibung[19], ro
V_DiagFehlerHistorie.Zeitpunkt[20] min, ro
V_DiagFehlerHistorie.Beschreibung[20], ro
V_DiagFehlerHistorie.Zeitpunkt[21] min, ro
V_DiagFehlerHistorie.Beschreibung[21], ro
V_DiagFehlerHistorie.Zeitpunkt[22] min, ro
V_DiagFehlerHistorie.Beschreibung[22], ro
V_DiagFehlerHistorie.Zeitpunkt[23] min, ro
V_DiagFehlerHistorie.Beschreibung[23], ro
V_DiagFehlerHistorie.Zeitpunkt[24] min, ro
V_DiagFehlerHistorie.Beschreibung[24], ro
V_DiagFehlerHistorie.Zeitpunkt[25] min, ro
V_DiagFehlerHistorie.Beschreibung[25], ro
V_DiagFehlerHistorie.Zeitpunkt[26] min, ro
V_DiagFehlerHistorie.Beschreibung[26], ro
V_DiagFehlerHistorie.Zeitpunkt[27] min, ro
V_DiagFehlerHistorie.Beschreibung[27], ro
V_DiagFehlerHistorie.Zeitpunkt[28] min, ro
V_DiagFehlerHistorie.Beschreibung[28], ro
V_DiagFehlerHistorie.Zeitpunkt[29] min, ro
V_DiagFehlerHistorie.Beschreibung[29], ro
V_DiagFehlerHistorie.Zeitpunkt[30] min, ro
V_DiagFehlerHistorie.Beschreibung[30], ro
V_DiagFehlerHistorie.Zeitpunkt[31] min, ro
V_DiagFehlerHistorie.Beschreibung[31], ro
Messung
V_Messkonfig.Montageabstand * 1 + 0 mm, ro Dec.0
V_Messkonfig.Sendeleistung, ro
V_Delay.Ausschaltverzögerung Doppelbogen ms, ro
V_Delay.Einschaltverzögerung Fehlbogen ms, ro
V_Delay.Einschaltverzögerung Doppelbogen ms, ro
Schnittstellen
V_SchnittstellenAusgang.Ausgangsfunktion D1, ro
V_SchnittstellenAusgang.Ausgangsfunktion D2, ro
V_SchnittstellenAusgang.Ausgangslogik D1, ro
V_SchnittstellenAusgang.Ausgangslogik D2, ro
V_SchnittstellenEingang.Eingangscharakteristik, ro
Trigger und Synchronisation
V_SyncMux.Trigger Kanal, ro
V_SyncMux.Trigger Modus, ro
Bedienoberfläche
V_BedienungEingabe.Modus, ro
V_BedienungAusgabe.Modus, ro
Diagnose
V_DiagMessung.Material Inhomogenität * 0.1 + 0 %, ro Dec.1
V_DiagTeachin.Status, ro
V_DiagZeit.SIO-Modus * 0.01 + 0 ms, ro Dec.2
V_DiagZeit.IO-Link * 0.01 + 0 ms, ro Dec.2
V_VENDOR_Temperature.Aktuelle Temperatur * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Max. Sensortemperatur allzeit * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Min. Sensortemperatur allzeit * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Max. Sensortemperatur seit letztem Reset * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Min. Sensortemperatur seit letztem Reset * 0.1 + 0 °C, ro Dec.1
V_DiagLaufzeit.Betriebszeitzähler * 0.01666667 + 0 h, ro Dec.2
V_DiagLaufzeit.Betriebszeitzähler seit Reset * 0.01666667 + 0 h, ro Dec.2
V_DiagLaufzeit.Bootzyklen, ro
V_DiagLaufzeit.EEProm Schreibzyklen, ro
V_DiagCounter.Einzelbogen, ro
V_DiagCounter.Doppelbogen, ro
V_DiagCounter.Übersteuerung, ro
V_DiagCounter.Fehlbogen, ro
Rezeptspeicher-Konfiguration
V_Rezeptspeicher_Konfig.Teach-in Rezeptspeicher, ro
Rezeptspeicher 1
V_RezeptspeicherHV_Rezept1.Sendelänge, ro
V_RezeptspeicherHV_Rezept1.Verstärkung, ro
V_RezeptspeicherHV_Rezept1.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept1.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept1.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept1.CRC, ro
Rezeptspeicher 2
V_RezeptspeicherHV_Rezept2.Sendelänge, ro
V_RezeptspeicherHV_Rezept2.Verstärkung, ro
V_RezeptspeicherHV_Rezept2.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept2.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept2.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept2.CRC, ro
Rezeptspeicher 3
V_RezeptspeicherHV_Rezept3.Sendelänge, ro
V_RezeptspeicherHV_Rezept3.Verstärkung, ro
V_RezeptspeicherHV_Rezept3.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept3.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept3.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept3.CRC, ro
Rezeptspeicher 4
V_RezeptspeicherHV_Rezept4.Sendelänge, ro
V_RezeptspeicherHV_Rezept4.Verstärkung, ro
V_RezeptspeicherHV_Rezept4.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept4.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept4.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept4.CRC, ro
Rezeptspeicher LP 1
V_RezeptspeicherLV_Rezept1.Sendelänge, ro
V_RezeptspeicherLV_Rezept1.Verstärkung, ro
V_RezeptspeicherLV_Rezept1.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept1.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept1.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept1.CRC, ro
Rezeptspeicher LP 2
V_RezeptspeicherLV_Rezept2.Sendelänge, ro
V_RezeptspeicherLV_Rezept2.Verstärkung, ro
V_RezeptspeicherLV_Rezept2.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept2.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept2.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept2.CRC, ro
Rezeptspeicher LP 3
V_RezeptspeicherLV_Rezept3.Sendelänge, ro
V_RezeptspeicherLV_Rezept3.Verstärkung, ro
V_RezeptspeicherLV_Rezept3.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept3.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept3.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept3.CRC, ro
Rezeptspeicher LP 4
V_RezeptspeicherLV_Rezept4.Sendelänge, ro
V_RezeptspeicherLV_Rezept4.Verstärkung, ro
V_RezeptspeicherLV_Rezept4.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept4.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept4.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept4.CRC, ro

Diagnosis Menu
Gerätestatusinformationen
V_DeviceStatus
V_DetailedDeviceStatus
V_ErrorCount
Servicefunktionen
V_SystemCommand, Button:=126
Description=Die visuellen Anzeigen des Geräts werden auf das Lokalisierungsanzeigemuster umgeschaltet, wodurch das Erkennen eines Geräts in einer Anwendung erleichtert wird.
V_SystemCommand, Button:=127
Description=Das Lokalisierungsanzeigemuster wird gestoppt. Die optischen Anzeigen des Geräts zeigen wieder die gerätespezifischen Betriebszustände an.
V_SystemCommand, Button:=131
Description=Die Parameter des Geräts werden auf die Werkseinstellungen gesetzt und die Kommunikation wird bis zum nächsten Aus- und Einschalten gesperrt. Hinweis: Trennen Sie das Gerät direkt vom Master-Port!
Messdatenkanalbeschreibung
V_SSP_MDC_Descriptor
Diagnose
V_DiagMessung.Material Inhomogenität * 0.1 + 0 %, ro Dec.1
V_DiagTeachin.Status, ro
V_DiagZeit.SIO-Modus * 0.01 + 0 ms, ro Dec.2
V_DiagZeit.IO-Link * 0.01 + 0 ms, ro Dec.2
V_VENDOR_Temperature.Aktuelle Temperatur * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Max. Sensortemperatur allzeit * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Min. Sensortemperatur allzeit * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Max. Sensortemperatur seit letztem Reset * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Min. Sensortemperatur seit letztem Reset * 0.1 + 0 °C, ro Dec.1
V_SystemCommand, Button:=228
V_DiagLaufzeit.Betriebszeitzähler * 0.01666667 + 0 h, ro Dec.2
V_DiagLaufzeit.Betriebszeitzähler seit Reset * 0.01666667 + 0 h, ro Dec.2
V_DiagLaufzeit.Bootzyklen, ro
V_DiagLaufzeit.EEProm Schreibzyklen, ro
V_DiagCounter.Einzelbogen, ro
V_DiagCounter.Doppelbogen, ro
V_DiagCounter.Übersteuerung, ro
V_DiagCounter.Fehlbogen, ro
V_SystemCommand, Button:=172
Diagnose
V_DiagZusammenfassung.Messwert, ro
V_DiagZusammenfassung.Ausgang D1, ro
V_DiagZusammenfassung.Ausgang D2, ro
V_DiagZusammenfassung.Eingang C1, ro
V_DiagZusammenfassung.Eingang C2, ro
V_DiagZusammenfassung.Eingang C3, ro
Messwertaufzeichnung
V_HistogrammConfig.Event senden, rw
V_HistogrammConfig.Trigger, rw
V_HistogrammConfig.Modus, rw
V_HistogrammConfig.Post-Trigger, rw
V_HistogrammPufferHeader.Zeiger Ringpuffer, ro
V_SystemCommand, Button:=170
V_SystemCommand, Button:=171
V_HistogrammPuffer1, ro
V_HistogrammPuffer2, ro
V_HistogrammPuffer3, ro
V_HistogrammPuffer4, ro
V_HistogrammPuffer5, ro
V_HistogrammPuffer6, ro
V_HistogrammPuffer7, ro
V_HistogrammPuffer8, ro
V_HistogrammPuffer9, ro
V_HistogrammPuffer10, ro

Commissioning Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag
V_CP_ProductURI

Parameters Menu
Servicefunktionen
V_SystemCommand, Button:=129
Description=Die Parameter der technologiespezifischen Anwendung werden auf Standardwerte gesetzt. Identifikationsparameter bleiben unverändert. Ein Upload in den Datenspeicher des Masters wird ausgeführt, sofern in der Portkonfiguration des Masters aktiviert.
V_SystemCommand, Button:=131
Description=Die Parameter des Geräts werden auf die Werkseinstellungen gesetzt und die Kommunikation wird bis zum nächsten Aus- und Einschalten gesperrt. Hinweis: Trennen Sie das Gerät direkt vom Master-Port!
Allgemeine Einstellungen
V_SystemCommand, Button:=128
Description=Ein Warmstart wird ausgelöst und das Gerät in einen Ausgangszustand versetzt. Die Kommunikation wird vom Gerät unterbrochen und dann vom Master neu gestartet.
V_SystemCommand, Button:=129
Description=Die Parameter der technologiespezifischen Anwendung werden auf Standardwerte gesetzt. Identifikationsparameter bleiben unverändert. Ein Upload in den Datenspeicher des Masters wird ausgeführt, sofern in der Portkonfiguration des Masters aktiviert.
V_SystemCommand, Button:=130
Description=Die Parameter des Geräts werden auf die Werkseinstellungen zurückgesetzt. Hinweis: Ein Download des Datenspeichers wird möglicherweise beim nächsten Aus- und Einschalten ausgeführt und die Werkseinstellungen überschrieben!
V_SystemCommand, Button:=131
Description=Die Parameter des Geräts werden auf die Werkseinstellungen gesetzt und die Kommunikation wird bis zum nächsten Aus- und Einschalten gesperrt. Hinweis: Trennen Sie das Gerät direkt vom Master-Port!
Device access locks
V_DeviceAccessLocks.Lokale Parametrierung, rw
V_DeviceAccessLocks.Lokale Benutzerschnittstelle, rw
Teach-in Kanal
V_SystemCommand, Button:=161
V_SystemCommand, Button:=162
V_SystemCommand, Button:=169
V_SSP_TI_TeachResult
V_TeachinKonfig.Typ, rw
V_TeachinKonfig.Offset * 1 + 0 %, rw Dec.1
Messung
V_Messkonfig.Montageabstand * 1 + 0 mm, rw Dec.0
V_Messkonfig.Sendeleistung, rw
V_SystemCommand, Button:=173
V_Delay.Ausschaltverzögerung Doppelbogen ms, rw
V_Delay.Einschaltverzögerung Fehlbogen ms, rw
V_Delay.Einschaltverzögerung Doppelbogen ms, rw
Schnittstellen
V_SchnittstellenAusgang.Ausgangsfunktion D1, rw
V_SchnittstellenAusgang.Ausgangsfunktion D2, rw
V_SchnittstellenAusgang.Ausgangslogik D1, rw
V_SchnittstellenAusgang.Ausgangslogik D2, rw
V_SchnittstellenEingang.Eingangscharakteristik, rw
Trigger und Synchronisation
V_SyncMux.Trigger Kanal, rw
V_SyncMux.Trigger Modus, rw
Bedienoberfläche
V_BedienungEingabe.Modus, rw
V_BedienungAusgabe.Modus, rw
Rezeptspeicher-Konfiguration
V_Rezeptspeicher_Konfig.Teach-in Rezeptspeicher, rw
Rezeptspeicher 1
V_RezeptspeicherHV_Rezept1.Sendelänge, rw
V_RezeptspeicherHV_Rezept1.Verstärkung, rw
V_RezeptspeicherHV_Rezept1.Auswertungstyp, rw
V_RezeptspeicherHV_Rezept1.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherHV_Rezept1.Schwellwert Doppelbogen, rw
V_RezeptspeicherHV_Rezept1.CRC, rw
Rezeptspeicher 2
V_RezeptspeicherHV_Rezept2.Sendelänge, rw
V_RezeptspeicherHV_Rezept2.Verstärkung, rw
V_RezeptspeicherHV_Rezept2.Auswertungstyp, rw
V_RezeptspeicherHV_Rezept2.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherHV_Rezept2.Schwellwert Doppelbogen, rw
V_RezeptspeicherHV_Rezept2.CRC, rw
Rezeptspeicher 3
V_RezeptspeicherHV_Rezept3.Sendelänge, rw
V_RezeptspeicherHV_Rezept3.Verstärkung, rw
V_RezeptspeicherHV_Rezept3.Auswertungstyp, rw
V_RezeptspeicherHV_Rezept3.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherHV_Rezept3.Schwellwert Doppelbogen, rw
V_RezeptspeicherHV_Rezept3.CRC, rw
Rezeptspeicher 4
V_RezeptspeicherHV_Rezept4.Sendelänge, rw
V_RezeptspeicherHV_Rezept4.Verstärkung, rw
V_RezeptspeicherHV_Rezept4.Auswertungstyp, rw
V_RezeptspeicherHV_Rezept4.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherHV_Rezept4.Schwellwert Doppelbogen, rw
V_RezeptspeicherHV_Rezept4.CRC, rw
Rezeptspeicher LP 1
V_RezeptspeicherLV_Rezept1.Sendelänge, rw
V_RezeptspeicherLV_Rezept1.Verstärkung, rw
V_RezeptspeicherLV_Rezept1.Auswertungstyp, rw
V_RezeptspeicherLV_Rezept1.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherLV_Rezept1.Schwellwert Doppelbogen, rw
V_RezeptspeicherLV_Rezept1.CRC, rw
Rezeptspeicher LP 2
V_RezeptspeicherLV_Rezept2.Sendelänge, rw
V_RezeptspeicherLV_Rezept2.Verstärkung, rw
V_RezeptspeicherLV_Rezept2.Auswertungstyp, rw
V_RezeptspeicherLV_Rezept2.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherLV_Rezept2.Schwellwert Doppelbogen, rw
V_RezeptspeicherLV_Rezept2.CRC, rw
Rezeptspeicher LP 3
V_RezeptspeicherLV_Rezept3.Sendelänge, rw
V_RezeptspeicherLV_Rezept3.Verstärkung, rw
V_RezeptspeicherLV_Rezept3.Auswertungstyp, rw
V_RezeptspeicherLV_Rezept3.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherLV_Rezept3.Schwellwert Doppelbogen, rw
V_RezeptspeicherLV_Rezept3.CRC, rw
Rezeptspeicher LP 4
V_RezeptspeicherLV_Rezept4.Sendelänge, rw
V_RezeptspeicherLV_Rezept4.Verstärkung, rw
V_RezeptspeicherLV_Rezept4.Auswertungstyp, rw
V_RezeptspeicherLV_Rezept4.Ein- und Ausschaltverzögerung, rw
V_RezeptspeicherLV_Rezept4.Schwellwert Doppelbogen, rw
V_RezeptspeicherLV_Rezept4.CRC, rw

Observation Menu
Fehlerhistorie
V_DiagLaufzeit.Fehleranzahl, ro
detaillierte Fehlerhistorie
V_DiagFehlerHistorie.Zeitpunkt[0] min, ro
V_DiagFehlerHistorie.Beschreibung[0], ro
V_DiagFehlerHistorie.Zeitpunkt[1] min, ro
V_DiagFehlerHistorie.Beschreibung[1], ro
V_DiagFehlerHistorie.Zeitpunkt[2] min, ro
V_DiagFehlerHistorie.Beschreibung[2], ro
V_DiagFehlerHistorie.Zeitpunkt[3] min, ro
V_DiagFehlerHistorie.Beschreibung[3], ro
V_DiagFehlerHistorie.Zeitpunkt[4] min, ro
V_DiagFehlerHistorie.Beschreibung[4], ro
V_DiagFehlerHistorie.Zeitpunkt[5] min, ro
V_DiagFehlerHistorie.Beschreibung[5], ro
V_DiagFehlerHistorie.Zeitpunkt[6] min, ro
V_DiagFehlerHistorie.Beschreibung[6], ro
V_DiagFehlerHistorie.Zeitpunkt[7] min, ro
V_DiagFehlerHistorie.Beschreibung[7], ro
V_DiagFehlerHistorie.Zeitpunkt[8] min, ro
V_DiagFehlerHistorie.Beschreibung[8], ro
V_DiagFehlerHistorie.Zeitpunkt[9] min, ro
V_DiagFehlerHistorie.Beschreibung[9], ro
V_DiagFehlerHistorie.Zeitpunkt[10] min, ro
V_DiagFehlerHistorie.Beschreibung[10], ro
V_DiagFehlerHistorie.Zeitpunkt[11] min, ro
V_DiagFehlerHistorie.Beschreibung[11], ro
V_DiagFehlerHistorie.Zeitpunkt[12] min, ro
V_DiagFehlerHistorie.Beschreibung[12], ro
V_DiagFehlerHistorie.Zeitpunkt[13] min, ro
V_DiagFehlerHistorie.Beschreibung[13], ro
V_DiagFehlerHistorie.Zeitpunkt[14] min, ro
V_DiagFehlerHistorie.Beschreibung[14], ro
V_DiagFehlerHistorie.Zeitpunkt[15] min, ro
V_DiagFehlerHistorie.Beschreibung[15], ro
V_DiagFehlerHistorie.Zeitpunkt[16] min, ro
V_DiagFehlerHistorie.Beschreibung[16], ro
V_DiagFehlerHistorie.Zeitpunkt[17] min, ro
V_DiagFehlerHistorie.Beschreibung[17], ro
V_DiagFehlerHistorie.Zeitpunkt[18] min, ro
V_DiagFehlerHistorie.Beschreibung[18], ro
V_DiagFehlerHistorie.Zeitpunkt[19] min, ro
V_DiagFehlerHistorie.Beschreibung[19], ro
V_DiagFehlerHistorie.Zeitpunkt[20] min, ro
V_DiagFehlerHistorie.Beschreibung[20], ro
V_DiagFehlerHistorie.Zeitpunkt[21] min, ro
V_DiagFehlerHistorie.Beschreibung[21], ro
V_DiagFehlerHistorie.Zeitpunkt[22] min, ro
V_DiagFehlerHistorie.Beschreibung[22], ro
V_DiagFehlerHistorie.Zeitpunkt[23] min, ro
V_DiagFehlerHistorie.Beschreibung[23], ro
V_DiagFehlerHistorie.Zeitpunkt[24] min, ro
V_DiagFehlerHistorie.Beschreibung[24], ro
V_DiagFehlerHistorie.Zeitpunkt[25] min, ro
V_DiagFehlerHistorie.Beschreibung[25], ro
V_DiagFehlerHistorie.Zeitpunkt[26] min, ro
V_DiagFehlerHistorie.Beschreibung[26], ro
V_DiagFehlerHistorie.Zeitpunkt[27] min, ro
V_DiagFehlerHistorie.Beschreibung[27], ro
V_DiagFehlerHistorie.Zeitpunkt[28] min, ro
V_DiagFehlerHistorie.Beschreibung[28], ro
V_DiagFehlerHistorie.Zeitpunkt[29] min, ro
V_DiagFehlerHistorie.Beschreibung[29], ro
V_DiagFehlerHistorie.Zeitpunkt[30] min, ro
V_DiagFehlerHistorie.Beschreibung[30], ro
V_DiagFehlerHistorie.Zeitpunkt[31] min, ro
V_DiagFehlerHistorie.Beschreibung[31], ro
Messung
V_Messkonfig.Montageabstand * 1 + 0 mm, ro Dec.0
V_Messkonfig.Sendeleistung, ro
V_Delay.Ausschaltverzögerung Doppelbogen ms, ro
V_Delay.Einschaltverzögerung Fehlbogen ms, ro
V_Delay.Einschaltverzögerung Doppelbogen ms, ro
Schnittstellen
V_SchnittstellenAusgang.Ausgangsfunktion D1, ro
V_SchnittstellenAusgang.Ausgangsfunktion D2, ro
V_SchnittstellenAusgang.Ausgangslogik D1, ro
V_SchnittstellenAusgang.Ausgangslogik D2, ro
V_SchnittstellenEingang.Eingangscharakteristik, ro
Trigger und Synchronisation
V_SyncMux.Trigger Kanal, ro
V_SyncMux.Trigger Modus, ro
Bedienoberfläche
V_BedienungEingabe.Modus, ro
V_BedienungAusgabe.Modus, ro
Diagnose
V_DiagMessung.Material Inhomogenität * 0.1 + 0 %, ro Dec.1
V_DiagTeachin.Status, ro
V_DiagZeit.SIO-Modus * 0.01 + 0 ms, ro Dec.2
V_DiagZeit.IO-Link * 0.01 + 0 ms, ro Dec.2
V_VENDOR_Temperature.Aktuelle Temperatur * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Max. Sensortemperatur allzeit * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Min. Sensortemperatur allzeit * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Max. Sensortemperatur seit letztem Reset * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Min. Sensortemperatur seit letztem Reset * 0.1 + 0 °C, ro Dec.1
V_DiagLaufzeit.Betriebszeitzähler * 0.01666667 + 0 h, ro Dec.2
V_DiagLaufzeit.Betriebszeitzähler seit Reset * 0.01666667 + 0 h, ro Dec.2
V_DiagLaufzeit.Bootzyklen, ro
V_DiagLaufzeit.EEProm Schreibzyklen, ro
V_DiagCounter.Einzelbogen, ro
V_DiagCounter.Doppelbogen, ro
V_DiagCounter.Übersteuerung, ro
V_DiagCounter.Fehlbogen, ro
Rezeptspeicher-Konfiguration
V_Rezeptspeicher_Konfig.Teach-in Rezeptspeicher, ro
Rezeptspeicher 1
V_RezeptspeicherHV_Rezept1.Sendelänge, ro
V_RezeptspeicherHV_Rezept1.Verstärkung, ro
V_RezeptspeicherHV_Rezept1.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept1.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept1.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept1.CRC, ro
Rezeptspeicher 2
V_RezeptspeicherHV_Rezept2.Sendelänge, ro
V_RezeptspeicherHV_Rezept2.Verstärkung, ro
V_RezeptspeicherHV_Rezept2.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept2.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept2.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept2.CRC, ro
Rezeptspeicher 3
V_RezeptspeicherHV_Rezept3.Sendelänge, ro
V_RezeptspeicherHV_Rezept3.Verstärkung, ro
V_RezeptspeicherHV_Rezept3.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept3.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept3.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept3.CRC, ro
Rezeptspeicher 4
V_RezeptspeicherHV_Rezept4.Sendelänge, ro
V_RezeptspeicherHV_Rezept4.Verstärkung, ro
V_RezeptspeicherHV_Rezept4.Auswertungstyp, ro
V_RezeptspeicherHV_Rezept4.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherHV_Rezept4.Schwellwert Doppelbogen, ro
V_RezeptspeicherHV_Rezept4.CRC, ro
Rezeptspeicher LP 1
V_RezeptspeicherLV_Rezept1.Sendelänge, ro
V_RezeptspeicherLV_Rezept1.Verstärkung, ro
V_RezeptspeicherLV_Rezept1.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept1.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept1.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept1.CRC, ro
Rezeptspeicher LP 2
V_RezeptspeicherLV_Rezept2.Sendelänge, ro
V_RezeptspeicherLV_Rezept2.Verstärkung, ro
V_RezeptspeicherLV_Rezept2.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept2.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept2.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept2.CRC, ro
Rezeptspeicher LP 3
V_RezeptspeicherLV_Rezept3.Sendelänge, ro
V_RezeptspeicherLV_Rezept3.Verstärkung, ro
V_RezeptspeicherLV_Rezept3.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept3.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept3.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept3.CRC, ro
Rezeptspeicher LP 4
V_RezeptspeicherLV_Rezept4.Sendelänge, ro
V_RezeptspeicherLV_Rezept4.Verstärkung, ro
V_RezeptspeicherLV_Rezept4.Auswertungstyp, ro
V_RezeptspeicherLV_Rezept4.Ein- und Ausschaltverzögerung, ro
V_RezeptspeicherLV_Rezept4.Schwellwert Doppelbogen, ro
V_RezeptspeicherLV_Rezept4.CRC, ro

Diagnosis Menu
Gerätestatusinformationen
V_DeviceStatus
V_DetailedDeviceStatus
V_ErrorCount
Servicefunktionen
V_SystemCommand, Button:=126
Description=Die visuellen Anzeigen des Geräts werden auf das Lokalisierungsanzeigemuster umgeschaltet, wodurch das Erkennen eines Geräts in einer Anwendung erleichtert wird.
V_SystemCommand, Button:=127
Description=Das Lokalisierungsanzeigemuster wird gestoppt. Die optischen Anzeigen des Geräts zeigen wieder die gerätespezifischen Betriebszustände an.
V_SystemCommand, Button:=131
Description=Die Parameter des Geräts werden auf die Werkseinstellungen gesetzt und die Kommunikation wird bis zum nächsten Aus- und Einschalten gesperrt. Hinweis: Trennen Sie das Gerät direkt vom Master-Port!
Messdatenkanalbeschreibung
V_SSP_MDC_Descriptor
Diagnose
V_DiagMessung.Material Inhomogenität * 0.1 + 0 %, ro Dec.1
V_DiagTeachin.Status, ro
V_DiagZeit.SIO-Modus * 0.01 + 0 ms, ro Dec.2
V_DiagZeit.IO-Link * 0.01 + 0 ms, ro Dec.2
V_VENDOR_Temperature.Aktuelle Temperatur * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Max. Sensortemperatur allzeit * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Min. Sensortemperatur allzeit * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Max. Sensortemperatur seit letztem Reset * 0.1 + 0 °C, ro Dec.1
V_VENDOR_Temperature.Min. Sensortemperatur seit letztem Reset * 0.1 + 0 °C, ro Dec.1
V_SystemCommand, Button:=228
V_DiagLaufzeit.Betriebszeitzähler * 0.01666667 + 0 h, ro Dec.2
V_DiagLaufzeit.Betriebszeitzähler seit Reset * 0.01666667 + 0 h, ro Dec.2
V_DiagLaufzeit.Bootzyklen, ro
V_DiagLaufzeit.EEProm Schreibzyklen, ro
V_DiagCounter.Einzelbogen, ro
V_DiagCounter.Doppelbogen, ro
V_DiagCounter.Übersteuerung, ro
V_DiagCounter.Fehlbogen, ro
V_SystemCommand, Button:=172
Diagnose
V_DiagZusammenfassung.Messwert, ro
V_DiagZusammenfassung.Ausgang D1, ro
V_DiagZusammenfassung.Ausgang D2, ro
V_DiagZusammenfassung.Eingang C1, ro
V_DiagZusammenfassung.Eingang C2, ro
V_DiagZusammenfassung.Eingang C3, ro
Messwertaufzeichnung
V_HistogrammConfig.Event senden, rw
V_HistogrammConfig.Trigger, rw
V_HistogrammConfig.Modus, rw
V_HistogrammConfig.Post-Trigger, rw
V_HistogrammPufferHeader.Zeiger Ringpuffer, ro
V_SystemCommand, Button:=170
V_SystemCommand, Button:=171
V_HistogrammPuffer1, ro
V_HistogrammPuffer2, ro
V_HistogrammPuffer3, ro
V_HistogrammPuffer4, ro
V_HistogrammPuffer5, ro
V_HistogrammPuffer6, ro
V_HistogrammPuffer7, ro
V_HistogrammPuffer8, ro
V_HistogrammPuffer9, ro
V_HistogrammPuffer10, ro

Note: This page shows the content of an IODD file transformed into HTML format. In the case of disparity between this and the XML view, the content of the XML file takes precedence.