receiver für ultrasonic-double sheet control distance between transmitter and receiver can be selected
pulse operation with amplitude evaluation
400 kHz
7 mm in front of transmitter and receiver
papers with weights of 20 - 1,200 g/m2, metal-laminated sheets and films up to 0.4 mm thick, self-adhesive films, sheet metals up to 0.3 mm thick, fine corrugated card
only free-run mode: The dbk measures continuously. Should the control input stay unconnected or if it is set against -UB (UE < 5 V DC), the mounting gap between transmitter and receiver must be 40 mm. For a 60 mm mounting gap, the control input must be set at +UB (UE > 9 V DC) .
brass sleeve, nickel-plated, plastic parts, PBT
polyurethane foam, epoxy resin with glass contents
40 mm ± 3 mm resp. 60 mm ± 3 mm
± 45° from the perpendicular to the sheet
15 Nm
IP 65
+5°C to +60°C
-40°C to +85°C
130 g
not necessary
not necessary
1 x Duo-LED; green: working / red: double sheet / flashing green: missing sheet
receiver für ultrasonic-double sheet control distance between transmitter and receiver can be selected