• archivsensoren_1046x850.jpg

archiv sensor  dbk-4/Empf/CDD/ KU0,6/TB2

  • dbk-4/Empf/CDD/ KU0,6/TB2
  • pin assignment

    Pin assignment

sensor comparison

Page content as online catalogue (download)

documentation (download)

CAD files (download)

approvals and certificates (download)

EU-Declaration of conformity

dbk-4/Empf/CDD/ KU0,6/TB2
please ask about
  • 2 x pnp
papers with weights of 20 - 1,200 g/m2, metal-laminated sheets and films up to 0.4 mm thick, self-adhesive films, sheet metals up to 0.3 mm thick, fine corrugated card
special design
double sheet control
receiver for ultrasonic double sheet control
distance between transmitter and receiver can be selected
swapped-out ultrasonic transducer
special design
pulse operation with amplitude evaluation
400 kHz
7 mm in front of transmitter and receiver
20 - 30 V d.c., reverse polarity protection
± 10 %
≤ 45 mA
2 m PVC cable, 5 x 0.25 mm2
1 m PVC cable with 2-pin plug IP 20 to the transmitter, 0.6 m PV cable to the swapped out receiver
double sheet output
pnp: Imax = 500 mA (UB-2V)
NCC, short-circuit-proof
missing sheet output
pnp: Imax = 500 mA (UB-2V)
NCC, short-circuit-proof
2.5 ms or 6.5 ms in free-run mode
only free-run mode:
The dbk measures continuously. Should the control input stay unconnected or if it is set against -UB (UE < 5 V DC), the mounting gap between transmitter and receiver must be 40 mm.
For a 60 mm mounting gap, the control input must be set at +UB (UE > 9 V DC) .
control input
40 mm ± 3 mm resp. 60 mm ± 3 mm
± 45° from the perpendicular to the sheet
brass sleeve, nickel-plated, plastic parts, PBT
polyurethane foam, epoxy resin with glass contents
15 Nm
IP 65
+5°C to +60°C
-40°C to +85°C
175 g
not necessary
not necessary
1 x Duo-LED; green: working / red: double sheet / flashing green: missing sheet
receiver for ultrasonic double sheet control
distance between transmitter and receiver can be selected
swapped-out ultrasonic transducer
special design

accessories

Top