• archivsensoren_1046x850.jpg

archiv sensor  mic-601/IU/HV/M30E/ K5

  • mic-601/IU/HV/M30E/ K5
  • Detection zone

  • Scale drawing

  • pin assignment

    Pin assignment

sensor comparison

Page content as online catalogue (download)

documentation (download)

CAD files (download)

approvals and certificates (download)

mic-601/IU/HV/M30E/ K5
please ask about
  • 1 x analogue 4-20 mA + 0-10 V
  • 8,000 mm
800 - 6,000 mm
cylindrical M30
analogue distance measurements
archive sensor
stainless steel version
cable connection
echo propagation time measurement
80 kHz
800 mm
6,000 mm
8,000 mm
1 mm
± 0.15 %
± 1 % (temperature drift internally compensated)
12 - 30 V d.c., reverse polarity protection
± 10 %
≤ 70 mA
5 m PVC cable, 5 x 0.25 mm2
analogue output
current: 4-20 mA / voltage: 0-10 V (at UB ≥ 15 V), short-circuit-proof
switchable rising/falling
240 ms
< 1,500 ms
com input
stainless steel, plastic parts: PBT, TPU
polyurethane foam, epoxy resin with glass contents
IP 65
-20°C to +70°C
-40°C to +85°C
yes
2 push-buttons + LED display (TouchControl)
Teach-in and numeric configuration via TouchControl
LCA-2 with LinkControl
2 x three-colour LED
archive sensor
stainless steel version
cable connection
Top