dbk+4 ultrasonic double-sheet control

dbk+4/3CDD/M18 E+S

  • dbk+4/3CDD/M18 E+S

    Sensorbild

  • Scale drawing

  • pin assignment

    Pin assignment

sensor comparison

Page content as online catalogue (download)

download sensor as pdf

documentation (download)

user's manual

CAD files (download)

SAT STEP IGS IPT PDF

approvals and certificates (download)

EU-Declaration of conformity UKCA Declaration of Conformity

  • 2 x pnp
papers with weights of 20 - 2,000 g/m2, Washi, metal-laminated sheets and films up to 0.4 mm thick, self-adhesive films, sheet metals up to 0.3 mm thick, fine corrugated card, wafers, PCBs
cylindrical M18
double sheet control
distance between transmitter and receiver can be selected
cable connection
pulse operation with amplitude evaluation
400 kHz
7 mm in front of transmitter and receiver
20 - 30 V d.c., reverse polarity protection
± 10 %
≤ 50 mA
2 m PUR cable, 7 x 0.14 mm2
at the receiver: 1.2 m PUR cable, at the transmitter: 1 m PUR cable with M8 initiator plug
double sheet output
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
missing sheet output
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
< 500 µs in trigger mode, 2.5 ms in free-run mode
< 300 ms
< -UB+18 V: logic 1; > -UB+13 V or control input open: logic 0
control input
control input
control input
20 - 60 mm; optimal: 40 mm ± 3 mm
± 45° from the perpendicular to the sheet
brass sleeve, nickel-plated, plastic parts, PBT, PA
polyurethane foam, epoxy resin with glass contents
15 Nm
IP 65
+5°C to +60°C
-40°C to +85°C
130 g
90° angular head
swapped-out transmitter/receiver
single transmitter/receiver
control input
working range selection via control inputs
Teach-in via control inputs
LCA-2 with LinkControl
1 x Duo-LED; green: working / red: double sheet / flashing red: missing sheet
distance between transmitter and receiver can be selected
cable connection

accessories

Top