The design of the wash-down stainless steel housing with no crevices and dirt edges makes pms sensor perfectly suited to intensive cleaning and disinfection.
sheeting with weights of < 20 g/m2 up to >> 600 g/m2, metal-laminated sheets and films up to 0.6 mm thick, self-adhesive films, labels on backing material
cylindrical M18
label/splice detection
pulse operation with amplitude evaluation
400 kHz
7 mm in front of transmitter and receiver
20 - 30 V d.c., reverse polarity protection
± 10 %
≤ 50 mA
2 m PUR cable, 7 x 0.14 mm2
at the receiver: 1.2 m PUR cable, at the transmitter: 1 m PUR cable with M8 initiator plug