- 1 x pnp
papers with weights of 20 - 1,200 g/m2, metal-laminated sheets and films up to 0.4 mm thick, self-adhesive films, sheet metals up to 0.3 mm thick, fine corrugated card
cylindrical M18
double sheet control
receiver for ultrasonic double sheet control
pulse operation with amplitude evaluation
400 kHz
7 mm in front of transmitter and receiver
20 - 30 V d.c., reverse polarity protection
± 10 %
≤ 35 mA
2 m PVC cable, 4 x 0.34 mm2
1.2 m PVC cable with 2-pin plug IP 20
double sheet output
pnp: Imax = 500 mA (UB-2V)
NCC, short-circuit-proof
pnp: Imax = 500 mA (UB-2V)
NCC, short-circuit-proof
6.5 ms in trigger mode, 24,5 ms in free-run mode
If the control input is pulled against +UB or -UB (UE < 0.1 x UB or UE > 0.9 x UB), then the dbk is deactivated; the switched output state before deactivation is frozen. The effect of the control input being triggered (0.3 x UB < UE < 0.7 x UB (IE ≤ 100 µs) or the control input being opened is for the dbk to start its measurements at a 6.5 ms response time (trigger mode).
The dbk continues to measure (free-run mode) at a 6.5 ms response time should it not again be deactivated. After 500 ms the response time in the free-run mode goes down to 24.5 ms and stays there.
The dbk continues to measure (free-run mode) at a 6.5 ms response time should it not again be deactivated. After 500 ms the response time in the free-run mode goes down to 24.5 ms and stays there.
control input
40 mm ± 3 mm
± 45° from the perpendicular to the sheet
brass sleeve, nickel-plated, plastic parts, PBT
polyurethane foam, epoxy resin with glass contents
15 Nm
IP 65
+5°C to +60°C
-40°C to +85°C
130 g
cuboidal receiver
different cable length
different cable length
not necessary
not necessary
1 x Duo-LED; green: working / red: double sheet
receiver for ultrasonic double sheet control