pms ultrasone sensoren

pms-25/CF/A1

  • pms-25/CF/A1

    Sensorbild

  • Detection zone

  • Scale drawing

  • Aansluitbelegging

    Pin assignment

vergelijking sensoren

page content as online catalogue (download)

download sensor als pdf

documentatie (download)

gebruiksaanwijzing IODD library IO-Link accompanying sheet

CAD data (download)

SAT STEP IGS IPT PDF

approvals and certificates (download)

EU-Declaration of conformity ECOLAB EHEDG IO-Link declaration of conformity UKCA Declaration of Conformity

  • 1 x Push-Pull
  • 350 mm
30 - 350 mm
Innovative housing design in washdown
IO-Link
naderingsschakelaar/reflexsensor
reflectiebarrière
venstermodus
The pms ultrasonic sensor in stainless steel housing is designed according to EHEDG guidelines.
hohe Chemiebeständigkeit
Edelstahlausführung
IO-Link
UL Listed
Hygienic Design
ECOLAB
EHEDG (TYPE EL Class I AUX)
echo-looptijdmeting
320 kHz
30 mm
250 mm
350 mm
0,10 mm
± 0,15 %
± 1 % (temperatuurdrift intern gecompenseerd)
10 V tot 30 V DC, ompoolbeveiligd
± 10 %
≤ 40 mA
4-polige, ronde M8-connector
schakeluitgang
Push-Pull, UB-3 V, -UB+3 V,Imax = 100 mA
3 mm
25 Hz
32 ms
< 300 ms
com-ingang
synchronisatie-ingang
teach-in-ingang
pms-25/CF/A1
35100
ja
COM2 (38,4 kBaud)
8 ms
4 Byte
Bit 0: Q1 schakeltoestand; Bit 8-15: scale (Int. 8); Bit 16-31: measured value (Int. 16)
Identification, measuring configuration, switched output, filter, temperature compensation, operation
SP1 Teach-in, SP2 Teach-in, factory settings
ja
IODD Versie 1.1
roestvrij staal
met PTFE-folie bekleed, FKM-O-ring
IP 66, IP 67, IP 68
85°C
-25° C tot +70° C
-40° C tot +85° C
140 g
ja
com-ingang
Teach-in via com input on pin 2
LCA-2 with LinkControl
IO-Link
yes, via external clock generator
hohe Chemiebeständigkeit
Edelstahlausführung
IO-Link
UL Listed
Hygienic Design
ECOLAB
EHEDG (TYPE EL Class I AUX)

toebehoren