are determined with a thin round bar (10 or 27 mm dia. depending on type of sensor) and indicate the typical operating range of a sensor.
In order to obtain the blue areas,
a plate (500 x 500 mm) is introduced into the beam spread from the side. In doing so, the optimum angle between plate and sensor is always employed. This therefore indicates the maximum detection zone of the sensor. It is not possible to evaluate ultrasonic reflections outside the blue beam spread
A reflector with reflective properties inferior to those of the round bar can be detected in a zone that is smaller than that indicated by the red area. On the other hand, a reflector with better reflective properties will be detected in a zone with a size somewhere between that of the red and blue areas.
A sensor's blind zone determines its smallest permissible detection range. No objects or disturbing reflectors should be placed in the blind zone because this can lead to incorrect measurements.
The operating ranges
given in the diagrams specify the distance at which the ultrasonic sensor can measure common reflectors with sufficient operating reserve. The sensor can also be employed for distances up to its maximum range in the case of good reflectors. The maximum detection range is always greater than the operating range. The diagrams apply for 20 °C, a relative humidity of 50% and normal pressure.