Archive sensor
wms-301/RT/HV/M30

Downloads

Page content as online catalogue

Documentation

CAD Files

wms-340/RT
  • echo output echo output
  • 5,000 mm 5,000 mm
350 - 5.000 mm
cylindrical M30
sensor for evaluators
archive sensor

Ultrasonic-Specific

echo propagation time measurement
120 kHz
350 mm
3.400 mm
5,000 mm
± 0.15 %
temperature drift 0.17 %/K

Electrical Data

10 - 30 V d.c., reverse polarity protection
± 10 %
≤ 30 mA
4-pin M12 initiator plug

Outputs

signal output echo
pnp: Imax = 10 mA (signal output echo)

Inputs

signal input - transmitter
40 ms

Control

controlled by open collector (npn), IC ≥ 3 mA, UCE ≥ 30 V

Housing

brass sleeve, nickel-plated, plastic parts, PBT
polyurethane foam, epoxy resin with glass contents
IP 65
-20°C to +70°C
-40°C to +85°C
280 g
stainless steel
cable connection (on request)

Technical Features/Characteristics

no
no
no
yes
yes
no
archive sensor