dbk+4/Empf/3BEE/M18

Bild von der dbk+4 Empfänger M18 Ultraschall-Doppelbogenkontrolle

Downloads

Page content as online catalogue

Documentation

  • 2 x npn 2 x npn
cylindrical M18
double sheet control
papers with weights of 20 - 2,000 g/m2, Washi, metal-laminated sheets and films up to 0.4 mm thick, self-adhesive films, sheet metals up to 0.3 mm thick, fine corrugated card, wafers, PCBs
receiver for ultrasonic double sheet control
distance between transmitter and receiver can be selected
cable connection

Technical Data - Mechanics

20 - 60 mm; optimal: 40 mm ± 3 mm
± 45° from the perpendicular to the sheet

Ultrasonic-Specific

pulse operation with amplitude evaluation
400 kHz
7 mm in front of transmitter and receiver

Electrical Data

20 - 30 V d.c., reverse polarity protection
± 10 %
≤ 50 mA
2 m PUR cable, 7 x 0.14 mm2
1.2 m PUR cable with M8 initiator plug

outputs

double sheet output
npn: Imax = 200 mA (-UB+2V)
NOC/NCC adjustable, short-circuit-proof
missing sheet output
npn: Imax = 200 mA (-UB+2V)
NOC/NCC adjustable, short-circuit-proof
< 500 µs in trigger mode, 2.5 ms in free-run mode
< 750 ms

Inputs

control input
control input
control input

response times

until next edge in trigger mode, 2.5 ms in free-run mode

control

< -UB+6 V: logic 1; > -UB+10 V or control input open: logic 0

housing

brass sleeve, nickel-plated, plastic parts, PBT, PA
polyurethane foam, epoxy resin with glass contents
IP 65
+5°C to +60°C
-40°C to +85°C
100 g
15 Nm
90°-Winkelkopf
ausgelagerter Sender/Empfänger

Technical Features/Characteristics

control input
working range selection via control inputs
Teach-in via control inputs
LCA-2 with LinkControl
1 x Duo-LED; green: working / red: double sheet / flashing red: missing sheet
receiver for ultrasonic double sheet control
distance between transmitter and receiver can be selected
cable connection

Accessories

ACCESSORIES

prev
next
Details zu LCA-2
LCA-2

LCA-2

For the convenient setting of a large number of microsonic sensor families. The LinkControl-Adapter LCA-2 can be used to read, copy or write parameters. Additionally, you can connect it with a PC in order to configurate it via LinkControl Software.
Details zu LCA-2 Koffer
LCA-2 Koffer

LCA-2 Koffer

Set for convenient setting of a number of microsonic sensor families.
Contents:
LCA-2
- Adaptor for sensors with cable connection (lcs) incl. cable clamps
- Adapter for power supply incl. cable clamps
- Power supply 90-240VAC/24VDC, 625 mA, with 2,5 m cable
- four exchangeable AC-plugs for use in Europe, USA, Great Britain and Australia
- USB - cable A-plug to B-plug
- USB stick with LinkControl software
- Manual (German / English)
Details zu UF-90/M18
UF-90/M18

UF-90/M18

beam deflector for sensors with M18 threaded sleeve and ≤ 0.35 m detection range
Details zu UF-90/M30
UF-90/M30

UF-90/M30

beam detector for sensors with M30 threaded sleeve and ≤ 1.3 m detection range
Details zu BF-18
BF-18

BF-18

fastening clamp for sensors with M18 threaded sleeve
Details zu BF-30
BF-30

BF-30

fastening clamp for sensors with M30 threaded sleeve
Details zu MW-ZWS 2
MW-ZWS 2

MW-ZWS 2

mounting bracket for zws-7/-15/-24 sensors
Details zu MW-ZWS 3
MW-ZWS 3

MW-ZWS 3

mounting bracket for zws-7/-15/-24 sensors
Details zu MW-LCS 1
MW-LCS 1

MW-LCS 1

adapter plate for lcs sensors from 2007 year of manufacture - for using the fixing holes of the predecessor model
Details zu M18x1
M18x1

M18x1

fixing nut M18x1
Details zu KST5A-2/M12
KST5A-2/M12

KST5A-2/M12

cable, 5 contacts, female angled connector M12, cable length 2 m
Details zu KST5A-5/M12
KST5A-5/M12

KST5A-5/M12

cable, 5 contacts, female angled connector M12, cable length 5 m
Details zu KST5A-10/M12
KST5A-10/M12

KST5A-10/M12

cable, 5 contacts, female angled connector M12, cable length 10 m

Recently Viewed