esf-1/CDF/A

IO-Link
Bild vom esf-1 Ultraschall-Spleiß- und Etikettensensor
  • 1 x Push-Pull + 1 x pnp 1 x Push-Pull + 1 x pnp
fork-like
IO-Link
label/splice detection
sheeting with weights of < 20 g/m2 up to >> 400 g/m2, metal-laminated sheets and films up to 0.2 mm thick, self-adhesive films, labels on backing material
IO-Link
Smart Sensor Profile
UL Listed

Technical Data - Mechanics

6 mm
70 mm

Ultrasonic-Specific

pulse operation with amplitude evaluation
500 kHz

Electrical Data

20 - 30 V d.c., reverse polarity protection
± 10 %
≤ 50 mA
5-pin M12 initiator plug

outputs

switching output
label/splice detected
Push-Pull, UB-3 V, -UB+3 V,Imax = 100 mA
NOC/NCC adjustable, short-circuit-proof
switching output
label/splice detected
web break
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
300 µs up to 2,25 ms, dependent on the material
< 300 ms

Inputs

com input
synchronisation input
teach-in input

housing

aluminium anodized
polyurethane foam, epoxy resin with glass contents
IP 65
+5°C to +60°C
-40°C to +85°C
80 g
esf-1/15/CDF/A
larger fork width/depth

Technical Features/Characteristics

1 push-button<br/>com input
Teach-in and QuickTeach via push-button
Teach-in via com input on pin 5
LCA-2 with LinkControl
IO-Link
yes
1 x LED green: working, 1 x LED yellow: switch status Pin 4, 1 x LED red: switch status Pin 2
IO-Link
Smart Sensor Profile
UL Listed

IO-Link

esf-1/CDF/A
16950
yes
COM2 (38,4 kBaud)
4 ms
32 Bit PDI
Bit 0: initial state Pin 4; Bit 1: initial state Pin 2; Bit 2: web break; Bit 8-15: scale (Int. 8); Bit 16-31: measured value (Int. 16)
Identification, switched output, add-ons, temperature compensation, operation
SP1 Teach-in, SP2 Teach-in, factory settings
yes
IODD version 1.1

ACCESSORIES

prev
next
Details zu LCA-2
LCA-2

LCA-2

For the convenient setting of a large number of microsonic sensor families. The LinkControl-Adapter LCA-2 can be used to read, copy or write parameters. Additionally, you can connect it with a PC in order to configurate it via LinkControl Software.
Details zu LCA-2 Koffer
LCA-2 Koffer

LCA-2 Koffer

Set for convenient setting of a number of microsonic sensor families.
Contents:
LCA-2
- Adaptor for sensors with cable connection (lcs) incl. cable clamps
- Adapter for power supply incl. cable clamps
- Power supply 90-240VAC/24VDC, 625 mA, with 2,5 m cable
- four exchangeable AC-plugs for use in Europe, USA, Great Britain and Australia
- USB - cable A-plug to B-plug
- USB stick with LinkControl software
- Manual (German / English)
Details zu UF-90/M18
UF-90/M18

UF-90/M18

beam deflector for sensors with M18 threaded sleeve and ≤ 0.35 m detection range
Details zu UF-90/M30
UF-90/M30

UF-90/M30

beam detector for sensors with M30 threaded sleeve and ≤ 1.3 m detection range
Details zu BF-18
BF-18

BF-18

fastening clamp for sensors with M18 threaded sleeve
Details zu BF-30
BF-30

BF-30

fastening clamp for sensors with M30 threaded sleeve
Details zu MW-ZWS 2
MW-ZWS 2

MW-ZWS 2

mounting bracket for zws-7/-15/-24 sensors
Details zu MW-ZWS 3
MW-ZWS 3

MW-ZWS 3

mounting bracket for zws-7/-15/-24 sensors
Details zu MW-LCS 1
MW-LCS 1

MW-LCS 1

adapter plate for lcs sensors from 2007 year of manufacture - for using the fixing holes of the predecessor model
Details zu M18x1
M18x1

M18x1

fixing nut M18x1
Details zu KST5A-2/M12
KST5A-2/M12

KST5A-2/M12

cable, 5 contacts, female angled connector M12, cable length 2 m
Details zu KST5A-5/M12
KST5A-5/M12

KST5A-5/M12

cable, 5 contacts, female angled connector M12, cable length 5 m
Details zu KST5A-10/M12
KST5A-10/M12

KST5A-10/M12

cable, 5 contacts, female angled connector M12, cable length 10 m