dbk+5 ultrasonic double sheet control

dbk+5/3BEE/M18 E+S

  • dbk+5/3BEE/M18 E+S
  • Scale drawing

  • pin assignment

    Pin assignment

sensor comparison

Page content as online catalogue (download)

download sensor as pdf

documentation (download)

user's manual

CAD files (download)

SAT STEP IGS IPT PDF

approvals and certificates (download)

EU-Declaration of conformity

dbk+5/3BEE/M18 E+S
  • 2 x npn
papers with weights of 100 - 2,000 g/m2, plastic sheets and films up to 5 mm thick*, self-adhesive films, sheet metals up to 2 mm thick*, corrugated card, wafers, PCBs (*: material-dependent)
cylindrical M18
double sheet control
distance between transmitter and receiver can be selected
cable connection
pulse operation with amplitude evaluation
200 kHz
7 mm in front of transmitter and receiver
20 - 30 V d.c., reverse polarity protection
± 10 %
≤ 50 mA
2 m PUR cable, 7 x 0.14 mm2
at the receiver: 1.2 m PUR cable, at the transmitter: 1 m PUR cable with M8 initiator plug
double sheet output
npn: Imax = 200 mA (-UB+2V)
NOC/NCC adjustable, short-circuit-proof
missing sheet output
npn: Imax = 200 mA (-UB+2V)
NOC/NCC adjustable, short-circuit-proof
< 500 µs im Trigger-Mode, 5,5 ms im Free-Run‐Mode
< 750 ms
< -UB+18 V: logic 1; > -UB+13 V or control input open: logic 0
control input
control input
control input
30 - 70 mm; optimal: 50 mm ± 3 mm
± 45° from the perpendicular to the sheet
brass sleeve, nickel-plated, plastic parts, PBT, PA
polyurethane foam, epoxy resin with glass contents
15 Nm
IP 65
+5°C to +60°C
-40°C to +85°C
160 g
single transmitter/receiver
control input
Teach-in
LCA-2 with LinkCopy or LinkControl software
1 x Duo-LED; green: working / red: double sheet / flashing red: missing sheet
distance between transmitter and receiver can be selected
cable connection

accessories

Top