esf+1/CFF/Pro
Downloads
Page content as online catalogue
CAD Files
Approvals and certificates
IO-Link
-
2 x Push-Pull
fork-like
IO-Link
label/splice detection
label/splice detection
Flat fork leg
Mounting adapter for 2 mounting positions
Swivelling M12 connector
IO-Link
Recipe management
Measurement cycle time ≥ 150 µs to 2 ms (depending on material)
Mounting adapter for 2 mounting positions
Swivelling M12 connector
IO-Link
Recipe management
Measurement cycle time ≥ 150 µs to 2 ms (depending on material)
Technical Data - Mechanics
6 mm
68 mm
Ultrasonic-Specific
pulse operation with amplitude evaluation
500 kHz
Electrical Data
20 - 30 V d.c., reverse polarity protection
± 10 %
≤ 50 mA
5-pin M12 initiator plug
outputs
switching output
web break
Push-Pull, UB-1 V, -UB+1 V, Imax = 100 mA
NOC/NCC adjustable, short-circuit-proof
web break
Push-Pull, UB-1 V, -UB+1 V, Imax = 100 mA
NOC/NCC adjustable, short-circuit-proof
switching output
label/splice detected
Push-Pull, UB-1 V, -UB+1 V, Imax = 100 mA
NOC/NCC adjustable, short-circuit-proof
label/splice detected
Push-Pull, UB-1 V, -UB+1 V, Imax = 100 mA
NOC/NCC adjustable, short-circuit-proof
≥ 260 µs
< 300 ms
Inputs
com input
teach-in input
teach-in input
housing
PA-GF50
polyurethane foam, epoxy resin with glass contents
IP 65
+5°C to +60°C
-40°C to +85°C
60 g
Technical Features/Characteristics
1 push-button<br/>com input
Teach-in via push-button
Teach-in via com input on pin 5
LCA-2 with LinkControl
IO-Link
Teach-in via com input on pin 5
LCA-2 with LinkControl
IO-Link
yes
1 x LED grün: Power, 1 x LED gelb: Output, 1 x LED rot: Error
Flat fork leg
Mounting adapter for 2 mounting positions
Swivelling M12 connector
IO-Link
Recipe management
Measurement cycle time ≥ 150 µs to 2 ms (depending on material)
Mounting adapter for 2 mounting positions
Swivelling M12 connector
IO-Link
Recipe management
Measurement cycle time ≥ 150 µs to 2 ms (depending on material)
IO-Link
esf+1/CFF/Pro
16955
yes
COM3 (230.4 kBaud)
600 µs
32 Bit PDI
Bit 0: initial state Pin 4; Bit 1: initial state Pin 2; Bit 2-7: evaluation; Bit 8-15: scale (Int. 8); Bit 16-31: measured value (Int. 16)
Identifikation, Messung, Auswertung, Schaltausgang, Betriebsart, Bedienung, Messwerthistorie, Diagnose, Rezeptspeicher, Zählwerke, Add-ons
SP Teach-in, Locator, Reset device, Reset application, Factory settings, Back-to-box, Measurement recording, Reset counters, Teach-in transmitter/receiver distance, Reset diagnostic data
yes
IODD version 1.1.4