dbk+4/M12/3CFF/ M18 E+S

IO-Link
Bild von der dbk+4/CFFM Empfänger M12 M18 Ultraschall-Doppelbogenkontrolle

Downloads

Page content as online catalogue

Documentation

CAD Files

Approvals and certificates

  • 2 x Push-Pull 2 x Push-Pull
cylindrical M12 with a swapped-out ultrasonic transducer
IO-Link
Doppelbogenkontrolle
Papiere mit Grammaturen von 20 g/m2 bis 1.200 g/m2, Washi, metallkaschierte Bogen und Folien bis 0,2 mm Dicke, Selbstklebefolien, Bleche bis 0,3 mm
distance between transmitter and receiver can be selected
swapped-out ultrasonic transducer
M12
cable connection
IO-Link version 1.1

Technical Data - Mechanics

20 - 40 mm; optimal: 20 mm ± 3 mm
± 45° from the perpendicular to the sheet

Ultrasonic-Specific

pulse operation with amplitude evaluation
500 kHz
5 mm in front of transmitter and receiver

Electrical Data

18 - 30 V d.c., reverse polarity protection
± 10 %
≤ 50 mA
2 m PUR cable, 7 x 0.14 mm2
am Empfänger: 1,2 m PUR-Kabel, am Sender: 1 m PUR-Kabel, mit M8 Rundsteckverbinder; zum ausgelagerten Empfangswandler: 1,2 m PVC-Kabel

Outputs

double sheet output
Push-Pull, UB-1 V, -UB+1 V, Imax = 100 mA
NOC/NCC adjustable, short-circuit-proof
missing sheet output
Push-Pull, UB-1 V, -UB+1 V, Imax = 100 mA
NOC/NCC adjustable, short-circuit-proof
< 500 µs in trigger mode, 2.5 ms in free-run mode
< 300 ms

Inputs

control input
control input
control input<br /> com input<br /> sync input

Control

> 3/4 UB: logic 1; < 1/4 UB or control input open: logic 0

Housing

brass sleeve, nickel-plated, plastic parts, PBT, PA
polyurethane foam, epoxy resin with glass contents
IP 65
+5°C to +60°C
-40°C to +85°C
160 g
M18: 15 Nm, M12: 8 Nm

Technical Features/Characteristics

com input<br/>control input
working range selection via control inputs
Teach-in via control inputs
LCA-2 with LinkControl
IO-Link
yes
LEDs: green: working/single sheet / red: double sheet / flashing red: missing sheet / orange/green: overmodulation
distance between transmitter and receiver can be selected
swapped-out ultrasonic transducer
M12
cable connection
IO-Link version 1.1

IO-Link

dbk+4/M12/3CFF/M18
16556
yes
COM3 (230.4 kBaud)
2 ms
32 Bit PDI
Bit 0: initial state Pin 4; Bit 1: initial state Pin 2; Bit 2-7: evaluation; Bit 8-15: scale (Int. 8); Bit 16-31: measured value (Int. 16)
Identification, measurement, evaluation, switching output, operating mode, operation, measurement history, diagnostics, recipe memory, counters, add-ons
SP Teach-in, Locator, Reset device, Reset application, Factory settings, Back-to-box, Measurement recording, Reset counters, Teach-in transmitter/receiver distance, Reset diagnostic data
yes
IODD version 1.1.4

Accessories

Matching sensors

prev
next
Details zu dbk-Testbogen
dbk-Testbogen

dbk-Testbogen

test sheet for examining the mounting of the ultrasonic double sheet detector
Details zu BF-18
BF-18

BF-18

fastening clamp for sensors with M18 threaded sleeve
Details zu LCA-2
LCA-2

LCA-2

For the convenient setting of a large number of microsonic sensor families. The LinkControl-Adapter LCA-2 can be used to read, copy or write parameters. Additionally, you can connect it with a PC in order to configurate it via LinkControl Software.
Details zu LCA-2 Koffer
LCA-2 Koffer

LCA-2 Koffer

Set for convenient setting of a number of microsonic sensor families.<br/>Contents:<br/>LCA-2<br/>- Adaptor for sensors with cable connection (lcs) incl. cable clamps<br/>- Adapter for power supply incl. cable clamps<br/>- Power supply 90-240VAC/24VDC, 625 mA, with 2,5 m cable<br/>- four exchangeable AC-plugs for use in Europe, USA, Great Britain and Australia<br/>- USB - cable A-plug to B-plug<br/>- USB stick with LinkControl software<br/>- Manual (German / English)

Recently Viewed