sks-15/CF/A

IO-Link
Bild vom sks Ultraschallsensor
  • 1 x Push-Pull 1 x Push-Pull
  • 250 mm 250 mm
20 - 250 mm
a parallelepipedo
IO-Link
sensore di prossimità/tastatore a riflessione
barriera a riflessione
modalità finestra
kleinste quaderförmige Bauform
schlankes Schallfeld
IO-Link
Smart Sensor Profile
UL Listed

Specifico d'ultrasuoni

misurazione della durata dell'eco
380 kHz
20 mm
150 mm
250 mm
0,10 mm
± 0,15 %
± 1 % (compensazione interna della temperatura)

Dati elettrici

10 V fino a 30 V DC, protetto contro inversioni di polarità
± 10 %
≤ 30 mA
connettore circolare M8 a 4 poli

Uscite

uscita de commutazione
Push-Pull, UB-3 V, -UB+3 V,Imax = 100 mA
2,0 mm
25 Hz
32 ms
< 300 ms

Entrate

ingresso di controllo

Custodia

ABS
poliuretano espanso, resine epossidiche con fibre di vetro
IP 67
-25° C fino a +70° C
-40° C fino a +85° C
8 g

Dotazione/Caratteristiche speciali

no
1 tasto
Teach-in via push-button
IO-Link
no
no
1 x LED verde: in funzione, 1 x LED giallo: stato di commutazione
kleinste quaderförmige Bauform
schlankes Schallfeld
IO-Link
Smart Sensor Profile
UL Listed

IO-Link

sks-15/CF/A
13009
sì
COM2 (38,4 kBaud)
8 ms
32 Bit PDI
Bit 0: initial state Pin 4; Bit 8-15: scale (Int. 8); Bit 16-31: measured value (Int. 16)
Identification, switched output, filter, temperature compensation, operation
SP1 Teach-in, SP2 Teach-in, factory settings
sì
Versione IODD 1.1

Sensori compatibili

prev
next
Details zu KST4A-2/M8
KST4A-2/M8

KST4A-2/M8

cable, 4 contacts, female angled connector M8, cable length 2 m
Details zu KST4A-5/M8
KST4A-5/M8

KST4A-5/M8

cable, 4 contacts, female angled connector M8, cable length 5 m
Details zu KST4G-2/M8
KST4G-2/M8

KST4G-2/M8

cable, 4 contacts, female cable connector M8, cable length 2 m
Details zu KST4G-5/M8
KST4G-5/M8

KST4G-5/M8

cable, 4 contacts, female cable connector M8, cable length 5 m
Details zu SoundPipe sks1
SoundPipe sks1

SoundPipe sks1

SoundPipe for sks ultrasonic sensors. SoundPipe sks1 intensively bundles the sound field and allows measurements in drill holes and openings with small diameters. Push the SoundPipe down on the transducer until it is flush with the sensor housing. Avoid axial tensile force on the SoundPipe, otherwise the SoundPipe may dismantle from the sks sensor.