esf+1/CFF/Exp

IO-Link
Bild des esf+1 pro Ultraschall-Spleiß- und Etikettensensor mit 500 kHz
  • 2 x Push-Pull 2 x Push-Pull
叉型
IO-Link
标签/接头检测
Flat fork leg
Mounting adapter for 2 mounting positions
Swivelling M12 connector
IO-Link
Recipe management

技术数据 - 机械

6 mm
68 mm

超声波特性

脉冲操作带有振幅估算
200 kHz

电气数据

20 - 30 V d.c.,反极性保护
± 10 %
≤ 50 mA
5芯M12接插件

输出量

卷材中断
Push-Pull, UB-1 V, -UB+1 V, Imax = 100 mA
常开/常闭,可调节,短路保护
检测到标签/接头
Push-Pull, UB-1 V, -UB+1 V, Imax = 100 mA
常开/常闭,可调节,短路保护
≥ 425 µs
< 300 ms

输入

com端输入
自学习输入

外壳

PA-GF50
泡沫聚氨酯,玻璃填充的环氧树脂
IP 65
+5°C至 +60°C之间
-40°C 到 +85°C
60 g

技术特点/特性

1 push-button<br/>com input
Teach-in via push-button
Teach-in via com input on pin 5
LCA-2 with LinkControl
IO-Link
1 x LED grün: Power, 1 x LED gelb: Output, 1 x LED rot: Error
Flat fork leg
Mounting adapter for 2 mounting positions
Swivelling M12 connector
IO-Link
Recipe management

IO-Link

esf+1/CFF/Exp
16956
COM3 (230.4 kBaud)
600 µs
32 Bit PDI
Bit 0: initial state Pin 4; Bit 1: initial state Pin 2; Bit 2-7: evaluation; Bit 8-15: scale (Int. 8); Bit 16-31: measured value (Int. 16)
Identifikation, Messung, Auswertung, Schaltausgang, Betriebsart, Bedienung, Messwerthistorie, Diagnose, Rezeptspeicher, Zählwerke, Add-ons
SP Teach-in, Locator, Reset device, Reset application, Factory settings, Back-to-box, Measurement recording, Reset counters, Teach-in transmitter/receiver distance, Reset diagnostic data
IODD版本1.1.4

recently viewed

prev
next