dbk+5/Empf/3BEE/M18
Downloads
Page content as online catalogue
Documentation
CAD Files
Approvals and certificates
-
2 x pnp
cylindrical M18
double sheet control
papers with weights of 100 - 2,000 g/m2, plastic sheets and films up to 5 mm thick*, self-adhesive films, sheet metals up to 2 mm thick*, corrugated card, wafers, PCBs (*: material-dependent)
receiver for ultrasonic double sheet control
distance between transmitter and receiver can be selected
cable connection
distance between transmitter and receiver can be selected
cable connection
Technical Data - Mechanics
30 - 70 mm; optimal: 50 mm ± 3 mm
± 45° from the perpendicular to the sheet
Ultrasonic-Specific
pulse operation with amplitude evaluation
200 kHz
7 mm in front of transmitter and receiver
Electrical Data
20 - 30 V d.c., reverse polarity protection
± 10 %
≤ 50 mA
2 m PUR cable, 7 x 0.14 mm2
1.2 m PUR cable with M8 initiator plug
outputs
double sheet output
npn: Imax = 200 mA (-UB+2V)
NOC/NCC adjustable, short-circuit-proof
npn: Imax = 200 mA (-UB+2V)
NOC/NCC adjustable, short-circuit-proof
missing sheet output
npn: Imax = 200 mA (-UB+2V)
NOC/NCC adjustable, short-circuit-proof
npn: Imax = 200 mA (-UB+2V)
NOC/NCC adjustable, short-circuit-proof
< 500 µs im Trigger-Mode, 5,5 ms im Free-Run‐Mode
< 750 ms
Inputs
control input
control input
control input
response times
until next edge in trigger mode, 5.5 ms in free-run mode
control
< -UB+18 V: logic 1; > -UB+13 V or control input open: logic 0
housing
brass sleeve, nickel-plated, plastic parts, PBT, PA
polyurethane foam, epoxy resin with glass contents
IP 65
+5°C to +60°C
-40°C to +85°C
15 Nm
Technical Features/Characteristics
control input
Teach-in
LCA-2 with LinkCopy or LinkControl software
LCA-2 with LinkCopy or LinkControl software
1 x Duo-LED; green: working / red: double sheet / flashing red: missing sheet
receiver for ultrasonic double sheet control
distance between transmitter and receiver can be selected
cable connection
distance between transmitter and receiver can be selected
cable connection