lcs+ Ultraschall-Abstandssensoren

lcs+

The lcs+ ultrasonic sensors come in a very compact square-shaped housing - with analogue or switching output + IO-Link.

Detection ranges:
  • Symbolische Darstellung eines Ultraschallsensor mit einer Tastweite von 3,4 m.3.4 m
  • Symbolische Darstellung eines Ultraschallsensor mit einer Tastweite von 6,0 m.6.0 m
Outputs:
  • Symbolische Darstellung 1 Push-Pull-Schaltausgang in pnp- und npn-Schaltungstechnik mit IO-Link-Schnittstelle
  • Symbolische Darstellung 2 Schaltausgänge
  • Symbolische Darstellung von einem Analogausgang
Cuboidal:

Highlights

  • Very compact housing dimensions only 62 mm x 62 mm x 37.2 mm
  • IO-Link interfacefor support of the new industry standard
  • Smart Sensor Profiles more transparency between IO-Link Devices
  • Synchronisation and multiplex mode for simultaneous operation of up to ten sensors in close quarters
  • 8 m maximum detection range
  • UL Listed to Canadian and US safety standards

Basics

  • 1 Push-Pull switching output, or 2 pnp switching outputs
  • Analogue output 4–20 mA and 0–10 V with automatic switching between current and voltage outputs
  • microsonic Teach-in by using button T1 and T2
  • 0.18 mm to 2.4 mm resolution
  • Temperature compensation
  • 9–30 V operating voltage
  • LinkControlfor configuration of sensors from a PC

Sensor matrix

The sensor matrix gives an overview of standard sensors from lcs+ family. Make your choice based on operating range and available outputs and click in the matrix.

The lcs+ ultrasonic sensors

have a block-like plastic housing with a base area of only 62 x 62 mm and four fastening bores.
The sensors are Listed to applicable UL Standards and requirements by UL for Canada and the US.

Two dual colour LEDs

show all operating statuses.

Using the two Teach-in buttons T1 and T2

the lcs+ sensors can be easily set (Teach-in).

Three output stages are available for selection:

Symbolische Darstellung 1 Push-Pull-Schaltausgang in pnp- und npn-Schaltungstechnik mit IO-Link-Schnittstelle1 Push-Pull switching output with pnp or npn switching technology with IO-Link interface
Symbolische Darstellung 2 Schaltausgänge2 pnp switching outputs
Symbolische Darstellung von einem Analogausgang1 analogue output 4–20 mA or 0–10 V

The Ics+ sensors with switching output have three operating modes:

  • Single switching point
  • Two-way reflective barrier
  • Window mode

Teach-in of a single switching point

  • Place object to be detected (1) at the desired distance
  • Push button T2 for about 3 seconds
  • Then push button T2 again for about 1 second
Teach-in of a switching point
Teach-in of a switching point
Teach-in of a two-way reflective barrier ultrasonic sensor
Teach-in of a two-way reflective barrier

Teach-in of a two-way reflective barrier

with a fixed mounted reflector

  • Push button T1 for about 3 seconds
  • Then push button T1 again for about 10 seconds

For setting the analogue output

  • Initially position the object to be detected to the sensor-close window limit (1)
  • Push button T1 for about 3 seconds
  • Then move the object to the sensor-distant window limit (2)
  • Then push button T1 again for about 1 second

For configuration of a window

with two switching points on a single switched output, the procedure is the same as setting the analogue.

Teach-in of an analogue characteristic or a window with two switching points
Synchronisation using pin 5
Synchronisation using pin 5

Easy to synchronise

If several lcs+ ultrasonic sensors are operated in one application, the can be synchronised via pin 5 to prevent.
If more than 10 sensors must be synchronised, this can be carried out with the SyncBox1 , which is available as an accessory. Synchronisation via pin 5 is also possible in IO-Link mode.

Analogue sensors

check the connected working resistance at the output and automatically switch to 4–20 mA current output or 0–10 V voltage output. 

NCC/NOC

and rising/falling analogue characteristics can also be set via the buttons.

LinkControl

permits comprehensive parameterisation of lcs+ ultrasonic sensors via the LinkControl adapter LCA-2 which connects the sensors to the PC.

Sensor über LCA-2 für die Programmierung am PC angeschlossen
Sensor connected to the PC via LCA-2 for programming

IO-Link

Ultrasonic sensors lcs+340/F/A and lcs+600/F/A have a Push-Pull switching output and support IO-Link in version 1.1 as well as the Smart Sensor profile.

You have special requirements?
Nothing as simple as that.

With us, you can easily find an individual solution. Let us talk about your application: +49 231 97 51 51-82.