Archive sensor
mic-101/IU/HV/M30E/ K4/2-10V R1

sensor image
detection zone
scale drawing

Downloads

Page content as online catalogue

Approvals and certificates

please inquire
  • 1 x analogue 1 x analogue
  • 2,000 mm 2,000 mm
200 - 2.000 mm
cylindrical M30
analogue distance measurements
archive sensor
stainless steel version
cable connection

Ultrasonic-Specific

echo propagation time measurement
200 kHz
200 mm
1.300 mm
2,000 mm
0.18 mm
± 0.15 %
± 1 % (temperature drift internally compensated)

Electrical Data

9 - 30 V d.c., reverse polarity protection
± 10 %
≤ 70 mA
4 m PVC cable, 5 x 0.25 mm2

outputs

analogue output
current: 4-20 mA / voltage: 2-10 V (at UB ≥ 15 V), short-circuit-proof
switchable rising/falling
110 ms
< 1,500 ms

Inputs

com input
synchronisation input

housing

stainless steel, plastic parts: PBT, TPU
polyurethane foam, epoxy resin with glass contents
IP 65
-20°C to +70°C
-40°C to +85°C
350 g

Technical Features/Characteristics

yes
2 push-buttons + LED display (TouchControl)<br/>com input
Teach-in and numeric configuration via TouchControl
LCA-2 with LinkControl
yes
yes
2 x three-colour LED
archive sensor
stainless steel version
cable connection