Archive sensor
mic-25/IU/HV/M30 R1

sensor image
detection zone
scale drawing
pin assignment

Downloads

Page content as online catalogue

Documentation

Approvals and certificates

mic+25/IU/TC
  • 1 x analogue 4-20 mA + 0-10 V 1 x analogue 4-20 mA + 0-10 V
  • 350 mm 350 mm
30 - 350 mm
cylindrical M30
analogue distance measurements
archive sensor

Ultrasonic-Specific

echo propagation time measurement
320 kHz
30 mm
250 mm
350 mm
0.18 mm
± 0.15 %
± 1 % (temperature drift internally compensated)

Electrical Data

9 - 30 V d.c., reverse polarity protection
± 10 %
≤ 70 mA
5-pin M12 initiator plug

outputs

analogue output
current: 4-20 mA / voltage: 0-10 V (at UB ≥ 15 V), short-circuit-proof
switchable rising/falling
50 ms
< 1,500 ms

Inputs

com input
synchronisation input

housing

brass sleeve, nickel-plated, plastic parts, PBT
polyurethane foam, epoxy resin with glass contents
IP 65
-20°C to +70°C
-40°C to +85°C
210 g
mic-25/IU/HV/M30E R1
stainless steel

Technical Features/Characteristics

yes
2 push-buttons + LED display (TouchControl)<br/>com input
Teach-in and numeric configuration via TouchControl
LCA-2 with LinkControl
yes
yes
2 x three-colour LED
archive sensor

Accessories