pico+100/WK/F/A

IO-Link
sensor image
detection zone
scale drawing
pin assignment
  • 1 x Push-Pull 1 x Push-Pull
  • 1,300 mm 1,300 mm
120 - 1.300 mm
cylindrical M18
IO-Link
proximity switch/reflective mode
reflective barrier
window mode
90°-Winkelkopf
IO-Link Version 1.1
Smart Sensor Profile
UL Listed

Ultrasonic-Specific

echo propagation time measurement
200 kHz
120 mm
1.000 mm
1,300 mm
0.10 mm
± 0.15 %
± 1 % (temperature drift internally compensated)

Electrical Data

10 - 30 V d.c., reverse polarity protection
± 10 %
≤ 40 mA
5-pin M12 initiator plug

outputs

switching output
Push-Pull, UB-3 V, -UB+3 V,Imax = 100 mA
20 mm
10 Hz
80 ms
< 300 ms

Inputs

com input
synchronisation input
teach-in input

housing

brass sleeve, nickel-plated, plastic parts, PBT
polyurethane foam, epoxy resin with glass contents
IP 67
-25°C to +70°C
-40°C to +85°C
35 g
15 Nm

Technical Features/Characteristics

yes
com input
IO-Link
LCA-2 with LinkControl
Teach-in via com input on pin 5
yes
yes
1 x LED green: working, 1 x LED yellow: switch status
90°-Winkelkopf
IO-Link Version 1.1
Smart Sensor Profile
UL Listed

IO-Link

pico+100/WK/F/A
12801
yes
COM2 (38,4 kBaud)
20 ms
32 Bit PDI
Bit 0: initial state Pin 4; Bit 8-15: scale (Int. 8); Bit 16-31: measured value (Int. 16)
Identification, measuring configuration, switched output, filter, temperature compensation, operation
SP1 Teach-in, SP2 Teach-in, factory settings
yes
IODD version 1.1