pms-100/CU/A1

sensor image
detection zone
scale drawing
pin assignment
  • 1 x analogue 0-10 V 1 x analogue 0-10 V
  • 1,300 mm 1,300 mm
120 - 1.300 mm
Innovative housing design in washdown
analogue distance measurements
stainless steel version
high chemical resistance
UL Listed
Hygienic Design
ECOLAB
EHEDG (TYPE EL Class I AUX)

Ultrasonic-Specific

echo propagation time measurement
200 kHz
120 mm
1.000 mm
1,300 mm
0.069 mm to 0.38 mm, depending on the analogue window
± 0.15 %
± 1 % (temperature drift internally compensated)

Electrical Data

15 V bis 30 V DC, verpolfest
± 10 %
≤ 40 mA
4-pin M8 initiator plug

outputs

analogue output
voltage: 0-10 V, short-circuit-proof
switchable rising/falling
60 ms
< 300 ms

Inputs

com input
teach-in input

housing

stainless steel
coated with PTFE film, FKM O-ring
IP 66, IP 67, IP 68
-25°C to +70°C
-40°C to +85°C
85
140 g

Technical Features/Characteristics

yes
com input
Teach-in via com input on pin 2
LCA-2 with LinkControl
stainless steel version
high chemical resistance
UL Listed
Hygienic Design
ECOLAB
EHEDG (TYPE EL Class I AUX)

Accessories

The pms ultrasonic sensor in stainless steel housing is designed according to EHEDG guidelines.

Recently Viewed

prev
next