pms-25/CI/A1
Downloads
Page content as online catalogue
Documentation
CAD Files
Approvals and certificates
IO-Link
-
1 x analogue 4-20 mA
-
350 mm
30 - 350 mm
Innovative housing design in washdown
analogue distance measurements
stainless steel version
high chemical resistance
UL Listed
Hygienic Design
ECOLAB
EHEDG (TYPE EL Class I AUX)
high chemical resistance
UL Listed
Hygienic Design
ECOLAB
EHEDG (TYPE EL Class I AUX)
Ultrasonic-Specific
echo propagation time measurement
320 kHz
30 mm
250 mm
350 mm
0.069 mm to 0.10 mm, depending on the analogue window
± 0.15 %
± 1 % (temperature drift internally compensated)
Electrical Data
10 - 30 V d.c., reverse polarity protection
± 10 %
≤ 40 mA
4-pin M8 initiator plug
outputs
analogue output
current: 4-20 mA
switchable rising/falling
current: 4-20 mA
switchable rising/falling
24 ms
< 300 ms
Inputs
com input
teach-in input
teach-in input
housing
stainless steel
coated with PTFE film, FKM O-ring
IP 66, IP 67, IP 68
-25°C to +70°C
-40°C to +85°C
85
140 g
Technical Features/Characteristics
yes
com input
Teach-in via com input on pin 2
LCA-2 with LinkControl
LCA-2 with LinkControl
stainless steel version
high chemical resistance
UL Listed
Hygienic Design
ECOLAB
EHEDG (TYPE EL Class I AUX)
high chemical resistance
UL Listed
Hygienic Design
ECOLAB
EHEDG (TYPE EL Class I AUX)
Accessories
The pms ultrasonic sensor in stainless steel housing is designed according to EHEDG guidelines.