hps+ 초음파 센서

Sensorbild - Matrix

개요

hps+ in safety gear - When you need chemically resistant, pressure-resistant sensors.

센서 라인에 관하여 pdf로 다운 받으세요

하이라이트

  • Optionally used in normal pressure or overpressure
  • PTFE membrane for protection against aggressive media
  • Stainless-steel or optional PVDF housing for hps+340 for use in the food industry
  • Sealed against the housing with an O-ring made from FFKM for the highest possible chemical resistance
  • Digital display with direct measured value output in mm/cm or %
  • Numeric configuration of the sensor using digital display
  • UL Listed to Canadian and US safety standards

Basics

  • 2 switching outputs in pnp variant
  • Analogue output plus 1 pnp switching output
  • 4 detection ranges with a measurement range of 30 mm to 8 m
  • microsonic Teach-in using T1 or T2 buttons
  • 0.025 mm to 2.4 mm resolution
  • Temperature compensation
  • 9–30 V operating voltage
  • LinkControl for configuration of sensors from a PC

설명

새로운 hps+ 센서들은 테프론 필름으로- 표준으로- 장비하여야합니다.

새로운 hps+센서들의 초음파 트랜듀서는 표준으로 테프론 필름으로 장비 되어야 합니다. 그리고 그러한 센서들은 1.4571 스테인레스 스틸 혹은 PVDF로 구성된 FFKM O-ring으로 봉인 되어야 합니다. 이러한 것들은 위험한 물질들에 저항할 수 있는 높은 정도를 보증합니다.

hps+ 센서들은 탱크 안에서 6 기압까지 견디며 레벨 측정을 사용할 수 있습니다. 탱크에서의 압력-타이트(Pressure-tight)설치는 hps+340의 상황에서 1” 나사산 플렌지 또는 2”에 의한 방법으로 보증 되어야 합니다.

화학적 저항과 꽉 봉인하는 것은 셀룰로오스 시너로 채워진 것과 1,000,000번 교대로 압력 스트레스를 주어 실험하였습니다.

그림의 왼쪽.: 3.4m 동작 범위와 PVDF 또는 임의의 1.4571 스테인리스 스틸에서의 2” 나사산 플랜지를 가진 hps+340 그림의 오른쪽:  하우징에 대하여 FFKM O-ring으로 봉해진 PTFE 보호 필름

Two different output stages are available for four detection ranges:

2 switching outputs in pnp switching technology
1 analogue output with an additional pnp switching output

The hps+ sensors with switching output have three operating modes:

  • Single switching point
  • Two-way reflective barrier
  • Window mode

Two three-colour LEDs

always show the current state of the switching outputs or the analogue output.

With TouchControl

all configuration can be done right at the sensor. The easily legible three-digit LED display continually shows the current distance value and automatically switches between millimetre and centimetre displays.

Setting a switching or analogue output

can optionally be carried out by numeric input of the desired distance values, or using a Teach-in procedure. This permits the user to select the configuration method preferred. The hps+ sensors support synchronisation and multiplex operation and have extensive parameterisation options via LinkControl.
Further information on how to set up hps+ sensors can be found at mic+ sensors.

LinkControl 

consists of the LinkControl adapter and the LinkControl software and facilitates the configuration of the hps+ sensors via a PC or laptop with any conventional conventional Windows® operating system.

Sensor connected to the PC via LCA-2 for programming
Top