dbk+4 ultrasonic double-sheet control

dbk+4/Empf/3CDD/M18/ K7K2

  • dbk+4/Empf/3CDD/M18/ K7K2

    Sensorbild

  • Scale drawing

  • pin assignment

    Pin assignment

sensor comparison

Page content as online catalogue (download)

download sensor as pdf

documentation (download)

user's manual

CAD files (download)

approvals and certificates (download)

EU-Declaration of conformity UKCA Declaration of Conformity

  • 2 x pnp
papers with weights of 20 - 2,000 g/m2, Washi, metal-laminated sheets and films up to 0.4 mm thick, self-adhesive films, sheet metals up to 0.3 mm thick, fine corrugated card, wafers, PCBs
cylindrical M18
double sheet control
receiver für ultrasonic-double sheet control
distance between transmitter and receiver can be selected
long connection cable
pulse operation with amplitude evaluation
400 kHz
7 mm in front of transmitter and receiver
20 - 30 V d.c., reverse polarity protection
± 10 %
≤ 50 mA
2 m PUR cable, 7 x 0.14 mm2
2.3 m PUR cable with M8 initiator plug
double sheet output
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
missing sheet output
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
< 500 µs in trigger mode, 2.5 ms in free-run mode
< 300 ms
< -UB+18 V: logic 1; > -UB+13 V or control input open: logic 0
control input
control input
control input
20 - 60 mm; optimal: 40 mm ± 3 mm
± 45° from the perpendicular to the sheet
brass sleeve, nickel-plated, plastic parts, PBT, PA
polyurethane foam, epoxy resin with glass contents
15 Nm
IP 65
+5°C to +60°C
-40°C to +85°C
100 g
90°-Winkelkopf
ausgelagerter Sender/Empfänger
control input
working range selection via control inputs
Teach-in via control inputs
LCA-2 with LinkControl
1 x Duo-LED; green: working / red: double sheet / flashing red: missing sheet
receiver für ultrasonic-double sheet control
distance between transmitter and receiver can be selected
long connection cable
Top