archiv sensor  mic-302/IU/HV/M30/ ROP

  • mic-302/IU/HV/M30/ ROP
  • Detection zone

  • Scale drawing

  • pin assignment

    Pin assignment

sensor comparison

Page content as online catalogue (download)

documentation (download)

CAD files (download)

approvals and certificates (download)

mic-302/IU/HV/M30/ ROP
please ask about
  • 1 x analogue 4-20 mA + 0-10 V
  • 5,000 mm
350 - 3,400 mm
cylindrical M30
analogue distance measurements
archive sensor
customised
echo propagation time measurement
120 kHz
350 mm
3,400 mm
5,000 mm
± 0.15 %
± 1 % (temperature drift internally compensated)
± 10 %
analogue output
current: 4-20 mA / voltage: 0-10 V (at UB ≥ 15 V), short-circuit-proof
switchable rising/falling
50 ms
< 1,500 ms
com input
brass sleeve, nickel-plated, plastic parts, PBT, TPU
polyurethane foam, epoxy resin with glass contents
archive sensor