lcs ultrasonic sensors

lcs-35/DDD/QP

  • lcs-35/DDD/QP

    Sensorbild

  • Detection zone

  • Scale drawing

  • pin assignment

    Pin assignment

sensor comparison

Page content as online catalogue (download)

download sensor as pdf

documentation (download)

user's manual

CAD files (download)

approvals and certificates (download)

EU-Declaration of conformity UKCA Declaration of Conformity

  • 3 x pnp
  • 600 mm
65 - 600 mm
cuboidal
proximity switch/reflective mode
window mode
3 switched outputs
flat housing
lateral sound exit
echo propagation time measurement
400 kHz
65 mm
350 mm
600 mm
0.18 mm
± 0.15 %
± 1 % (temperature drift internally compensated)
9 - 30 V d.c., reverse polarity protection
± 10 %
≤ 70 mA
5-pin M12 initiator plug
switching output
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
switching output
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
switching output
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
5 mm
8 Hz
70 ms
< 300 ms
com input
PBT
polyurethane foam, epoxy resin with glass contents
IP 65
-25°C to +70°C
-40°C to +85°C
200 g
yes
com input
LCA-2 with LinkControl
no
no
3 x three-colour LED
3 switched outputs
flat housing
lateral sound exit

accessories