mic ultrasonic sensors

mic-130/DD/M

  • mic-130/DD/M

    Sensorbild

  • Detection zone

  • Scale drawing

  • pin assignment

    Pin assignment

sensor comparison

Page content as online catalogue (download)

download sensor as pdf

documentation (download)

user's manual

CAD files (download)

SAT STEP IGS IPT PDF

approvals and certificates (download)

EU-Declaration of conformity UKCA Declaration of Conformity

  • 2 x pnp
  • 2,000 mm
200 - 2.000 mm
cylindrical M30
proximity switch/reflective mode
window mode
metal plug for harsh operational conditions
echo propagation time measurement
200 kHz
200 mm
1,300 mm
2,000 mm
0.18 mm
± 0.15 %
± 1 % (temperature drift internally compensated)
9 - 30 V d.c., reverse polarity protection
± 10 %
≤ 55 mA
5-pin M12 initiator plug
switching output
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
switching output
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
20 mm
6 Hz
110 ms
< 300 ms
com input
brass sleeve, nickel-plated, plastic parts, PBT
polyurethane foam, epoxy resin with glass contents
IP 67
-25°C to +70°C
-40°C to +85°C
140 g
cable connection (on request)
yes
com input
LCA-2 with LinkCopy or LinkControl software
yes
no
no
metal plug for harsh operational conditions

accessories

Top