pms ultrasonic sensors

pms-35/CU/A1

  • pms-35/CU/A1
  • pin assignment

sensor comparison

Download page content as online catalogue

download sensor as pdf

documentation (download)

user's manual STEP IGS IPT PDF SAT

pms-35/CU/A1
  • 1 x analogue 0-10 V
  • 600 mm
65 - 600 mm
Innovative housing design in washdown
analogue distance measurements
stainless steel version
high chemical resistance
Hygienic Design
ECOLAB
EHEDG (TYPE EL Class I AUX)
echo propagation time measurement
400 kHz
65 mm
350 mm
600 mm
0.069 mm to 0.17 mm, depending on the analogue window
± 0.15 %
± 1 % (temperature drift internally compensated)
15 V bis 30 V DC, verpolfest
± 10 %
≤ 40 mA
4-pin M8 initiator plug
analogue output
voltage: 0-10 V, short-circuit-proof
switchable rising/falling
48 ms
< 300 ms
com input
synchronisation input
teach-in input
stainless steel
coated with PTFE film, FKM O-ring
IP 66, IP 67, IP 68
-25°C to +70°C
-40°C to +85°C
140 g
yes
com input
Teach-in via com input on pin 2
LCA-2 with LinkControl
yes, via external clock generator
stainless steel version
high chemical resistance
Hygienic Design
ECOLAB
EHEDG (TYPE EL Class I AUX)

accessories

Top