dbk+4 ultrasonic double-sheet control

dbk+4/M12/3BEE/M18 E+S

  • dbk+4/M12/3BEE/M18 E+S
  • Scale drawing

  • pin assignment

    Pin assignment

sensor comparison

Page content as online catalogue (download)

download sensor as pdf

documentation (download)

user's manual

CAD files (download)

SAT STEP IGS IPT PDF

approvals and certificates (download)

EU-Declaration of conformity UKCA Declaration of Conformity

dbk+4/M12/3BEE/M18 E+S
  • 2 x npn
papers with weights of 20 - 600 g/m2, Washi, metal-laminated sheets and films up to 0.2 mm thick, self-adhesive films
cylindrical M12 with a swapped-out ultrasonic transducer
double sheet control
distance between transmitter and receiver can be selected
swapped-out ultrasonic transducer
M12
cable connection
pulse operation with amplitude evaluation
500 kHz
5 mm in front of transmitter and receiver
9 - 30 V d.c., reverse polarity protection
± 10 %
≤ 50 mA
2 m PUR cable, 7 x 0.14 mm2
am Empfänger: 1,2 m PUR-Kabel, am Sender: 1 m PUR-Kabel, mit M8 Rundsteckverbinder; zum ausgelagerten Empfangswandler: 1,2 m PVC-Kabel
double sheet output
npn: Imax = 200 mA (-UB+2V)
NOC/NCC adjustable, short-circuit-proof
missing sheet output
npn: Imax = 200 mA (-UB+2V)
NOC/NCC adjustable, short-circuit-proof
< 500 µs in trigger mode, 2.5 ms in free-run mode
< 750 ms
< -UB+6 V: logic 1; > -UB+10 V or control input open: logic 0
control input
control input
control input
20 - 40 mm; optimal: 20 mm ± 2 mm
± 45° from the perpendicular to the sheet
brass sleeve, nickel-plated, plastic parts, PBT, PA
polyurethane foam, epoxy resin with glass contents
M18: 15 Nm, M12: 3 Nm
IP 65
+5°C to +60°C
-40°C to +85°C
160 g
single transmitter/receiver
control input
working range selection via control inputs
Teach-in via control inputs
LCA-2 with LinkControl
1 x Duo-LED; green: working / red: double sheet / flashing red: missing sheet
distance between transmitter and receiver can be selected
swapped-out ultrasonic transducer
M12
cable connection

accessories

Top