pms ultrasonic sensors

pms-15/CU/A1

  • pms-15/CU/A1

    Sensorbild

  • Detection zone

  • Scale drawing

  • pin assignment

    Pin assignment

sensor comparison

Page content as online catalogue (download)

download sensor as pdf

documentation (download)

user's manual IODD library

CAD files (download)

SAT STEP IGS IPT PDF

approvals and certificates (download)

EU-Declaration of conformity ECOLAB EHEDG UKCA Declaration of Conformity

  • 1 x analogue 0-10 V
  • 250 mm
20 - 250 mm
Innovative housing design in washdown
analogue distance measurements
The pms ultrasonic sensor in stainless steel housing is designed according to EHEDG guidelines.
hohe Chemiebeständigkeit
Edelstahlausführung
UL Listed
Hygienic Design
ECOLAB
EHEDG (TYPE EL Class I AUX)
echo propagation time measurement
380 kHz
20 mm
150 mm
250 mm
0.069 mm
± 0.15 %
± 1 % (temperature drift internally compensated)
15 V bis 30 V DC, verpolfest
± 10 %
≤ 40 mA
4-pin M8 initiator plug
analogue output
voltage: 0-10 V, short-circuit-proof
switchable rising/falling
24 ms
< 300 ms
com input
synchronisation input
teach-in input
stainless steel
coated with PTFE film, FKM O-ring
IP 66, IP 67, IP 68
85°C
-25°C to +70°C
-40°C to +85°C
140 g
yes
com input
Teach-in via com input on pin 2
LCA-2 with LinkControl
yes, via external clock generator
hohe Chemiebeständigkeit
Edelstahlausführung
UL Listed
Hygienic Design
ECOLAB
EHEDG (TYPE EL Class I AUX)

accessories

Top