dbk+4 ultrasonic double-sheet control

dbk+4/Empf/M12/3BEE/ M18

  • dbk+4/Empf/M12/3BEE/ M18

    Sensorbild

  • Scale drawing

  • pin assignment

    Pin assignment

sensor comparison

Page content as online catalogue (download)

download sensor as pdf

documentation (download)

user's manual

CAD files (download)

SAT STEP IGS IPT PDF

approvals and certificates (download)

EU-Declaration of conformity UKCA Declaration of Conformity

  • 2 x npn
papers with weights of 20 - 600 g/m2, Washi, metal-laminated sheets and films up to 0.2 mm thick, self-adhesive films
cylindrical M12 with a swapped-out ultrasonic transducer
double sheet control
receiver for ultrasonic double sheet control
distance between transmitter and receiver can be selected
swapped-out ultrasonic transducer
M12
cable connection
pulse operation with amplitude evaluation
500 kHz
5 mm in front of transmitter and receiver
20 - 30 V d.c., reverse polarity protection
± 10 %
≤ 50 mA
2 m PUR cable, 7 x 0.14 mm2
1 m PUR cable with M8 initiator plug to the transmitter, 1.2 m PVC cable to the swapped out receiver
double sheet output
npn: Imax = 200 mA (-UB+2V)
NOC/NCC adjustable, short-circuit-proof
missing sheet output
npn: Imax = 200 mA (-UB+2V)
NOC/NCC adjustable, short-circuit-proof
< 500 µs in trigger mode, 2.5 ms in free-run mode
< 750 ms
< -UB+6 V: logic 1; > -UB+10 V or control input open: logic 0
control input
control input
control input
20 - 40 mm; optimal: 20 mm ± 2 mm
± 45° from the perpendicular to the sheet
brass sleeve, nickel-plated, plastic parts, PBT, PA
polyurethane foam, epoxy resin with glass contents
M18: 15 Nm, M12: 3 Nm
IP 65
+5°C to +60°C
-40°C to +85°C
140 g
control input
working range selection via control inputs
Teach-in via control inputs
LCA-2 with LinkControl
1 x Duo-LED; green: working / red: double sheet / flashing red: missing sheet
receiver for ultrasonic double sheet control
distance between transmitter and receiver can be selected
swapped-out ultrasonic transducer
M12
cable connection

accessories